12.07.2015 Views

FIREsafe and Insurer Approved Building Envelope Solutions

FIREsafe and Insurer Approved Building Envelope Solutions

FIREsafe and Insurer Approved Building Envelope Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

For more information on Kingspan Insulated Panels visit www.barbourproductsearch.infoLPS 1181 PART 1 - GRADE A (EXT-A)N/ALPS 1181 PART 1 - GRADE B (EXT-B)LPCB Core 40, 50, 60, 70, 80 & 100mmMain fix every valley - External stitchers @ 450mm centresProduct Ref: KS1000 RW ECOsafe RoofN/ALPCB Core 45, 50, 60, 70, 80 & 100mmProduct Ref: KS1000 TS ECOsafe Roof*Approval limited to use with non-combustablewalls <strong>and</strong> max 54kg/m 2 tile weight.LPS 1181 PART 1 - GRADE A (EXT-A15)LPCB Core 40,50, 60, 70, 80 & 100mm *Horizontally or vertically laid - Maximum rail centres 3mMain fix every valley - External stitchers @ 300mm centresProduct Ref: KS1000 RW ECOsafe WallKS1000 RW/FW (EXT-A30) 100mmLPCB Core 70, 80 & 100mm *600, 900 & 1000mm wideHorizontally or vertically laid - Maximum rail centres 3mInternal fixings @ 250m centresProduct Ref: KS1000 MR ECOsafe WallLPS 1181 PART 1 - GRADE B (EXT-B)LPCB Core 40, 50, 60, 70, 80 & 100mmHorizontally or vertically laidMain fix every valley - External stitchers @ 300mm centresProduct Ref: KS1000 RW ECOsafe WallLPCB Core 45, 60, 70, 80 & 100mm600, 900 & 1000mm wideHorizontally or vertically laidProduct Ref: KS1000 MR ECOsafe WallBS 476: Part 22: Fire Resistance (Insulation & Integrity)TWO HOUR INTEGRITY FIREWALL - Core 40, 50, 60, 70, 80 & 100mm *Up to 18 mins insulation / Up to 144 mins integrityHorizontally or vertically laidMain fix every valley - External stitchers @ 300mm centresMaximum rail centres 3mTWO HOUR INTEGRITY FIREWALL - Core 45, 60, 70, 80 & 100mm *15 mins insulation / 120 mins integrityHorizontally or vertically laid0.4mm thick steel liner & 60mm 23kg/m 3 rock fibreMaximum rail centres 2mN/AN/A* Sheeting rails/cleats to have slotted connection <strong>and</strong> nylon washers.BS 476: Part 22: Fire Resistance (Food Sector <strong>Building</strong>s - Internal Panels)BS 476: Part 22: 1987 Clause 5 Walls (EN1364 Part 1)Thickness (mm) Integrity (E) Insulation (I) LPS 1208 Walls100mm 30 mins 30 mins Grading: FR30125mm 30 mins 30 mins Grading: FR30150mm 30 mins 30 mins Grading: FR30175mm 30 mins 30 mins Grading: FR30200mm 60 mins 60 mins Grading: FR60BS 476: Part 22: 1987 Clause 9 CeilingsThickness (mm) Integrity (E) Insulation (I) LPS 1208 Ceilings100mm 30 mins 30 mins Grading: FR30125mm 30 mins 30 mins Grading: FR30150mm 30 mins 30 mins Grading: FR30175mm 30 mins 30 mins Grading: FR30200mm 60 mins 60 mins Grading: FR609

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!