Elecon Measurements Pvt Ltd, Yelahanka,Communication <strong>Register</strong> <strong>Map</strong> <strong>eNavigator</strong> Series :This Communication map is for <strong>eNavigator</strong> series of meters. Depending on model, selected parametersdata can be retrieved. All the parameters declared in the communication map are either float or unsignedlong and follows the standard <strong>Modbus</strong> RTU protocol. The data can be retrieved individually or together asa block.S.No Parameter Data type <strong>Address</strong>1 Watts Total float 401012 Watts R phase float 401033 Watts Y phase float 401054 Watts B phase float 401075 VAR Total float 401096 VAR R phase float 401117 VAR Y phase float 401138 VAR B phase float 401159 PF Ave. (Instantaneous) float 4011710 PF R phase float 4011911 PF Y phase float 4012112 PF B phase float 4012313 VA total float 4012514 VA R phase float 4012715 VA Y phase float 4012916 VA B phase float 4013117 VLL average float 4013318 Vry phase float 4013519 Vyb phase float 4013720 Vbr phase float 4013921 VLN average float 4014122 V R phase float 4014323 V Y phase float 4014524 V B phase float 4014725 Current Total float 4014926 Current R phase float 4015127 Current Y phase float 4015328 Current B phase float 4015529 Frequency float 4015730 Wh received float 4015931 VAh received float 4016132 VARh Ind. Received float 4016333 VARh Cap. received float 40165Applicable for TM and LG SeriesPage 1 of 3


Elecon Measurements Pvt Ltd, Yelahanka,34 Wh Delivered float 4016735 VAh Delivered float 4016936 VARh Ind. Delivered float 4017137 VARh Cap. Delivered float 4017338 PF average Received float 4017539 Amps average Received float 4017740 PF average Delivered float 4017941 Amps average Delivered float 4018142 Neutral Current float 4018343 Voltage R Harmonics float 4018544 Voltage Y Harmonics float 4018745 Voltage B Harmonics float 4018946 Current R Harmonics float 4019147 Current Y Harmonics float 4019348 Current B Harmonics float 4019549 Rising Demand float 4019750 Forecast Demand float 4019951 Maximum Demand float 4020152 Reserved float 4020353 Reserved float 4020554 Reserved float 4020755 Reserved float 4020956 Reserved float 4021157 Reserved float 4021358 RPM float 4021559 Load Hours Received Unsigned long 4021760 Load Hours Delivered Unsigned long 4021961 No of interruptions Unsigned long 402212 nd Block73 TOD Slot-1 / Reserved float 4024574 TOD Slot-2 / Reserved float 4024775 TOD Slot-3 / Reserved float 4024976 TOD Slot-4 / Reserved float 4025177 TOD Slot-5 / Reserved float 4025378 TOD Slot-6 / Reserved float 4025579 Reserved float 4025779 Reserved float 4025980 Reserved float 4026181 Reserved float 4026382 Reserved float 4026583 Reserved float 40267Applicable for TM SeriesApplicable for EN SeriesOnlyPage 2 of 3


Elecon Measurements Pvt Ltd, Yelahanka,84 Reserved float 4026985 Reserved float 4027186 Analog input 1 float 4027387 Analog input 2 float 4027588 Digital input 1 Unsigned long 4027789 Digital input 2 Unsigned long 4027990 Digital input 3 Unsigned long 4028191 Digital input 4 Unsigned long 40283Page 3 of 3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!