Filter housing Cartridge filter AFW4-8 - MAHLE Industry - Filtration

mahle.industrialfiltration.com
  • No tags were found...

Filter housing Cartridge filter AFW4-8 - MAHLE Industry - Filtration

Filter housingCartridge filter AFW4-81. IntroductionThe amafilter AFW 4 - 8 cartridge filter housings are our smallestmultiple cartridge housings. Two models are available in stainlesssteel, suitable for various industrial applications.


2. Features3. Standard specifications■ Easy to use■ Heavy duty clamp cover closure■ O-ring sealing: standard Buna-N. Other materials on request.■ Compact design■ Pickled and passivated■ Suitable for 4 filter cartridges of 10” or 20” length■ Available from stock or at short noticeDesign pressure: 15 bar(g)Design temperature : 0 / 90 °COperating temperature: depending on the filter mediaand gaskets usedDesign: AD-2000 RegelwerkPED 97/23/EC cat. : article 3 paragraph 3mmMaximum differential pressuredesign: 2.5 baroperating: depending on type of filtercartridgeThe internal construction is designed to suit:■ Double Open End X0, X4 and X94. Models5. Filter cartridgesMAHLE Industrial Filtration can supply two standard sizes in stainlesssteel from stock. These are available with threaded connections.Other standard filter housingsWe also supply other standard filter housings suitable for allindustrial liquid and gas applications for various flow rates.For more information please contact your representative.MAHLE Industrial Filtration supplies a wide range of filter cartridgesin different materials, pore sizes, dimensions and models to fit inamafilter housings as well as those of other manufactures.For detailed information about filter cartridges, please contact yourrepresentative.Filter Housing AFW4-8 2


6. DimensionsNozzle specificationN1 :N2 :N3 :N4 :Inlet (Rp 2 - ISO7)Outlet (Rp 2 - ISO7)Vent (Rp¼ - ISO7)Drain (Rp½ - ISO7-1)DimensionsModel Diameter [mm]AStandout [mm]BHeight [mm]CNozze height [mm]DNozze height [mm]EVolume[dm³]Weight[kg]AFW4 168 130 535 300 150 11 11AFW8 168 130 790 300 150 16 13Height required for changing cartridges is height C plus cartridge length.Dimensions are for reference only. Use dimensional drawing for installation purposes.Subject to technical alteration without prior notice.7. Ordering codeExampleAFW4mmmmm 1 TQ 2amafilter typeAFW4AFW8Cartridge length1 = 10"2 = 20"MaterialT = 316Ti (1.4571) with quick release cover clampInlet/outlet2 = Rp2 - ISO7Filter Housing AFW4-8 3


MAHLE Industrial Filtration (Benelux) B.V.P.O.Box 396 1800 AJAlkmaar - The NetherlandsPhone +31 (0) 72 5273400Fax +31 (0) 72 5125207mahle.amafilter@mahle.comwww.mahle-industrialfiltration.com10/2009Filter Housing AFW4-8 4

More magazines by this user
Similar magazines