13.07.2015 Views

MEP-DC : the portable pressure calibrator! series M E P - Merkantile

MEP-DC : the portable pressure calibrator! series M E P - Merkantile

MEP-DC : the portable pressure calibrator! series M E P - Merkantile

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Series M E PS1C508E0-ME<strong>DC</strong>• TECHNICAL DATA• Compact, Lightweight and Shock ResistantCase.• IP68 (closed lid), IP 65 (open lid)• Simple front Panel with six boxed 4 mmgold plated copper sockets for signals:Input:Voltage Input (V),Current Input (mA)Contact Status: ON/OFF ( without voltage)Output:24 V dc to feed <strong>the</strong> transmitterIndications (LEDs):Charge (battery)TX (data Transmission)RX (data download)FAIL (failure)PWR (on/off)PS (on/off power supply 24 V)Commands ( push bottons)PWR/ZERO: ON/OFF (switch)/ZEROadjustmentPS/EU:ON/OFF (power supply 24 V)/Engineering Units Selection• Process Fluids: dry and clean air for <strong>MEP</strong>-<strong>DC</strong>, all fluids compatible with AISI 316 for<strong>MEP</strong>-<strong>DC</strong>E.• Serial Port RS 232 for linking <strong>the</strong> Palmand <strong>the</strong> Personal Computer• Power Supply: four 1,2 V batteries typeAA rechargeable (Nikel Metal Hydride)• Operating Limits:- Temperature: 0 °C ÷ 50 °C- Relative Humidity: 20 % ÷ 90 % noncondensing• Storage limits:- Temperature: - 20 °C ÷ 60 °C- Relative Humidity: 20 % ÷ 90 % noncondensing• EM Compatibility- Reference standards for electro-magneticcompatibility: CEI EN 61326-1 (1998)- Applicable standards for method &procedure:EN 55011 (1999), EN 61000-4-2 (1995)EN 61000-4-3 (1996), EN 61000-4-4(1995)• Dimensions: 270 x 230 x 170 mm• Weight: 2,3 kg• FUNCTIONS ON BOARD TO PalmThe supply of <strong>MEP</strong>-<strong>DC</strong> includes, on request,<strong>the</strong> Application Software mod. MCSW. If <strong>the</strong>Palm computer is supplied by Scandura, itwill be installed on board. O<strong>the</strong>rwise it will beinstalled on customer’s Palm by <strong>the</strong> userhimself (<strong>the</strong> cable <strong>MEP</strong>-<strong>DC</strong>/Palm is availableon request).The software includes <strong>the</strong> followingfunctions:• Pre-configuration for <strong>the</strong> calibration ofManometers, Pressure Transmitters andPressure Switches• Selection of Languages : English, Italian,French, o<strong>the</strong>rs on request• Simultaneous Display of two measuringchannels, Pressure (Ch1) and ElectricalTransmitter Output (Ch2), (V, mA orON/OFF status of Pressure Switch)• Display of a single channel whenconfigured as “Digital Manometer”• Trend Graphic Display of Pressure withAutomatic indication of min/max values• Heading of Test Reports: Display andEditing• Display of Test Reports• Storage, virtually unlimited of any ProcessInstrument Tag & Test Report. Each reportcarries 40 calibration points maxdistributed between “as found/as left”and “up/down”• Print out and of <strong>the</strong> Calibration Reportsdirectly from <strong>the</strong> Palm via Infrared orSerial Port.• E-mail transmission of any Test Report viaInfrared port and Mobile Phone providedwith Modem.• Full data Back-up on “SD” Card and/oron Personal Computer• <strong>MEP</strong>-Report, <strong>the</strong> software program todownload <strong>the</strong> calibration data from Palmto PC to print <strong>the</strong> calibration certificatesdirectly from <strong>the</strong> PC.• COMPATIBLE Palm COMPUTERSThe customer may decide to limit <strong>the</strong>purchase to <strong>the</strong> <strong>MEP</strong>-<strong>DC</strong> only, using at hisdiscretion any of <strong>the</strong> following models:Palm ZIRE 71Palm M515Palm M505Palm M500Palm M130Palm M125Operative Systems already verified: fromPalm OS 3.5.2 to Palm OS 5.The compatibility may be extended too<strong>the</strong>rs Palm computers using Palm OSoperative system. In <strong>the</strong>se casesScandura will carry out ex-factory <strong>the</strong>relevant operative tests.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!