10 05/06/06ssss:Meaning#### Each four-digit number represents the total hours that a lamphas been ON. The VIVID Blue, LX65 <strong>and</strong> RoadRunner L6 will respondwith two four digit numbers – one per lamp: <strong>Lamp</strong>1 <strong>Lamp</strong> 2 (CR).The VIVID White, LX100 <strong>and</strong> RoadRunner L8 will respond with four, fourdigit numbers – one per lamp: <strong>Lamp</strong>1 <strong>Lamp</strong>2 <strong>Lamp</strong>3 <strong>Lamp</strong>4 (CR).Table 4.4Status Item Code(x)ContentsResponse4 Setting Read s(CR)ss:Meaning11 Configured for Front Screen•Floor Mount10 Configured for Rear Screen•Ceiling Mount.01 Configured for Rear Screen•Floor Mount00 Configured for Front Screen•Ceiling MountTable 4.6Status Item Code(x)Contents6 Temperature ReadResponse_ss.s_ss.s_(CR)Note: _: spacess.s:MeaningNumbers First temperature reading is the sensor near the panel. Thesecond reading is near the lamp. Units are Celsius. This item isused for service purposes.Ex. _31.5__35.2_ means a temperature of 31.5 o C <strong>and</strong> 35.2 o C-05.5_-01.2_ means a temperature of –5.5 o C <strong>and</strong> –1.2 o CE00.0 Error reading temperatureTable 4.7Status Item Code(x)Contents7 <strong>Lamp</strong> Mode ReadResponsessCR)ss: Meaning for VIVID Blue L6, LX65 <strong>and</strong> MX250000 Full <strong>Lamp</strong> Mode: All OFF01 Full <strong>Lamp</strong> Mode: No. 1 ON, No. 2 OFF02 Full <strong>Lamp</strong> Mode: No. 2 ON, No. 1 OFFWhite, Blue, LX65/100/120, L6, L8, MX2500, MX3500, LU77 & LW40 <strong>Serial</strong> Communication
11 05/06/060F Full <strong>Lamp</strong> Mode: All ON10 Half <strong>Lamp</strong> Mode 1: All OFF11 Half <strong>Lamp</strong> Mode 1: No. 1 ON, No. 2 OFF20 Half <strong>Lamp</strong> Mode 2: All OFF22 Half <strong>Lamp</strong> Mode 2: No. 2 ON, No. 1 OFFNOTE:If you receive a response that is not found in these tables then the projector is in transition of lampmodes. Resend the comm<strong>and</strong> in one (1) minute.ss:Meaning for VIVID White L8, LX100, LU77 <strong>and</strong> MX350000 Full <strong>Lamp</strong> Mode: All OFF01 Full <strong>Lamp</strong> Mode: No. 1 ON, No. 2, 3, 4 OFF02 Full <strong>Lamp</strong> Mode: No. 2 ON, No. 1, 3, 4 OFF03 Full <strong>Lamp</strong> Mode: No. 1, 2 ON, No. 3, 4 OFF04 Full <strong>Lamp</strong> Mode: No. 3 ON, No. 1, 2, 4 OFF05 Full <strong>Lamp</strong> Mode: No. 1, 3 ON, No. 2, 4 OFF06 Full <strong>Lamp</strong> Mode: No. 2, 3 ON, No. 1, 4 OFF07 Full <strong>Lamp</strong> Mode: No. 1, 2, 3 ON, No. 4 OFF08 Full <strong>Lamp</strong> Mode: No. 4 ON, No. 1, 2, 3 OFF09 Full <strong>Lamp</strong> Mode: No. 1, 4 ON, No. 2, 3 OFF0A Full <strong>Lamp</strong> Mode: No. 2, 4 ON, No. 1, 3 OFF0C Full <strong>Lamp</strong> Mode: No. 3, 4 ON, No. 1, 2 OFF0D Full <strong>Lamp</strong> Mode: No. 1, 3, 4 ON, No. 2 OFF0E Full <strong>Lamp</strong> Mode: No. 2, 3, 4 ON, No. 1 OFF0F Full <strong>Lamp</strong> Mode: All ON10 Half <strong>Lamp</strong> Mode 1: All OFF11 Half <strong>Lamp</strong> Mode 1: No. 1 ON, No. 2, 3, 4 OFF18 Half <strong>Lamp</strong> Mode 1: No. 4 ON, No. 1, 2, 3 OFF19 Half <strong>Lamp</strong> Mode 1: No. 1, 4 ON, No. 2, 3 OFF20 Half <strong>Lamp</strong> Mode 2: All OFF22 Half <strong>Lamp</strong> Mode 2: No. 2 ON, No. 1, 3, 4 OFF24 Half <strong>Lamp</strong> Mode 2: No. 3 ON, No. 1, 2, 4 OFF26 Half <strong>Lamp</strong> Mode 2: No. 2, 3 ON, No. 1, 4 OFFNOTE: If you receive a response that is not found in these tables then the projector is in transition of lampmodes. Resend the comm<strong>and</strong> in one (1) minute.Table 4.9Status Item Code(x)ContentsResponse9 PC Type Read See below chartResponseSt<strong>and</strong> byAV ModeGo PC adj.No signalsssssMeaning<strong>Projector</strong> is OFF.Current source is video.PC System is set to AUTONo source on current input.Where sssss is the name of an RGB source that’s in thePC System window look up table.White, Blue, LX65/100/120, L6, L8, MX2500, MX3500, LU77 & LW40 <strong>Serial</strong> Communication