Power factor correctionand harmonic filteringCapacitors and banks 50 Hz 0400/415 V network voltageL600 power factor correction modulesPB100025DB102217DB102213L600 power factor correction modulesform a prewired automatic compensationsubassembly designed for mountingin universal cubicles. Different typesare available according to the level ofharmonic pollutionL600 power factor correction moduleL600 module dimensions (depth of cubicle: 400 mm)Standard type capacitorsNo polluted network (Gh/Sn y 15 %)L600 power factor correction modules400/415 V In (A) Fuse: Ref. Weight(kvar) size (kg)25 Single 36 T00 51577 1030 Single 43 T00 51578 1150 Single 72 T00 51579 1660 Single 87 T00 51580 1712.5 + 25 Double 54 T00 51583 1315 + 15 Double 43 T00 51581 1115 + 30 Double 65 T00 51584 1425 + 25 Double 72 T00 51585 2030 + 30 Double 87 T00 51582 20Overrated type capacitorsPolluted network (15 % < Gh/Sn y 25 %)L600 power factor correction modules400/415 V 470 V In (A) Fuse: Ref. Weight(kvar) (kvar) size (kg)25 34.5 Single 36 T00 51586 1450 69 Single 72 T00 51587 1712.5 + 25 17 + 35 Double 54 T00 51588 1425 + 25 35 + 35 Double 72 T00 51589 18Overrated type capacitors for association with detuned reactorHighly polluted network (25 % < Gh/Sn y 50 %)L600 power factor correction modules400/415 V Reactor (1)In (A) Fuse: Ref. WeightTuning order(kvar) (2) (kvar) size (kg)25 3.8 (190 Hz) / 4.3 (215 Hz) Single 36 T00 51591 13.650 3.8 (190 Hz) / 4.3 (215 Hz) Single 72 T00 51592 11.312.5 + 25 3.8 (190 Hz) / 4.3 (215 Hz) Double 54 T00 51593 14.2525 + 25 3.8 (190 Hz) / 4.3 (215 Hz) Double 72 T00 51594 17.525 2.7 (135 Hz) Single 36 T00 51595 13.650 2.7 (135 Hz) Single 72 T00 51596 11.312.5 + 25 2.7 (135 Hz) Double 54 T00 51597 14.2525 + 25 2.7 (135 Hz) Double 72 T00 51598 17.5(1) Detuned reactor out of supply.(2) Usefull power when used with detuned reactor.Technical datab capacitor rated voltage:v standard type: 400/415 V three-phase 50 Hzv overrated and HR type: 470 V three-phase 50 Hzb capacitance value tolerance: -5, +10 %b insulation level:v 0.69 kVv withstand 50 Hz, 1 min: 2.5 kVb maximum permissible current (400 V):v standard type: 1.3 Inv overrated type: 1.5 Inv HR type: 2.7 (135 Hz): 1.12 In, 3.8 (190 Hz): 1.19 In, 4.3 (215 Hz): 1.31 Inb maximum permissible voltage increase (8 hours over 24 hours as in IEC 60831): 460 Vb ambient temperature around the equipment (electrical room):v maximum temperature: 40 °Cv average temperature over 24 hrs: 35 °Cv average annual temperature: 25 °Cv minimum temperature: -5 °Cb losses: 2.5 W/kvar for standard, overrated and HR typeb degree of protection: front-face with direct contact protectionb standards: IEC 60439-1, EN 60439-1.21 mars 2005437E3280_Ver4.0.fm/1


Power factor correctionand harmonic filteringCapacitors and banks 50 Hz 0400/415 V network voltageL600 power factor correction modulesDB102214DB102218AccessoriesRef.Set of 3 modular bars L600 51540Set of 3 connection pads L600 51590Adaptation kit L600 51539ref. 51590Connection padsDB102216ref. 51539Adaptation kitInstallationb mounting:v in 600 mm wide cubiclev in 700 or 800 mm wide cubicle using the adaptation kitv in Prisma Plus cubicle W = 650 mm using the installation system specificref. 03976 (refer to Prisma Plus catalog pages)b fastened to cubicle columns using fastening cross-members (not supplied)b vertical distance between modules: 25 mm minimumb control circuit power supply: 230 V/50 Hz.ref. 51540Modular bars437E3280_Ver4.0.fm/2 21 mars 2005

More magazines by this user
Similar magazines