Cat. No. <strong>RD</strong>-C<strong>Analog</strong> <strong>Sensor</strong> Controller<strong>RD</strong> <strong>Series</strong>Six unique and useful functions give the <strong>RD</strong> superior flexibility andease-of-use to expand analog sensor applications.Features❏ Six unique functions including a linearizer,high-/low-pass filters... and moreThese six useful and convenient functions eliminate noise interferenceor other undesired components, ignore analog signal componentswith frequencies above or below a specified level, andlinearizes the analog input signal for increased accuracy.❏ High-speed sampling rate of 2,000 c/sEnsures accurate measurement even on high-speed lines.❏ Easy-to-read three-color LED displayDisplays green when the measurement value is within the tolerancelimits, orange or red when it is not. Large LED characters allow youto easily read measured values and to differentiate between acceptableand unacceptable products even from a long distance.❏ Quick and easy setting of tolerance andother valuesAll settings can be performed quickly and easily using the <strong>RD</strong>’s tenoperation keys.


<strong>RD</strong> <strong>Series</strong>A high- and low-pass filter combined with the linearizer functiongive the analog sensor signal unparalleled accuracyLinearizer functionThe <strong>RD</strong> series provides up to32-point calibration for analogsignals input from the sensor,enabling the input signal can beprecisely regulated. And up tofour sets of correction valuescan be stored.Raw dataLinearized dataLinearized data outside|measuring rangeRaw data outsidemeasuring rangeHigh-pass filterBy removing the low-frequencycomponents of the analog inputsignal, gradual changes in thesignal are ignored, allowing onlysporadic fluctuations to bedetected.Filtered data showing height differenceonly (height is ignored)Data showing heightdifference and heightData showing number ofgear teeth and eccentricityFiltered data showing number of gearteeth only (eccentricity is ignored)Low-pass filterBy removing the high-frequencycomponents of the analog inputsignal, high-frequency fluctuationsin the signal are ignored,allowing only gradual changes tobe detected.Filtered dataFiltered data showing eccentricity only(gear teeth are ignored)Data containing noiseData showing gear teeth and eccentricity


<strong>RD</strong> <strong>Series</strong>The <strong>RD</strong> series can be used with a wide range of systemconfigurationsSystem configurationLX seriesLB series<strong>Analog</strong> outputConvenientfeatures<strong>Analog</strong> voltage outputLaserThrubeam<strong>Sensor</strong>EX seriesLaserDisplacement<strong>Sensor</strong>UD seriesX (<strong>Analog</strong> signal)Y (<strong>Analog</strong> signal)Digital I/ORS-232CPLCKV seriesOscilloscopeThe analog voltage output can beadjusted to a level suitable forexternal equipment using thespan and/or shift function.Digits/decimal pointInductiveGauging<strong>Sensor</strong>External output equipmentPressuregaugeUltrasonicDisplacement<strong>Sensor</strong>HHHIGOLOLL<strong>RD</strong>-50RTIMINGSELECT No.<strong>Analog</strong> <strong>Sensor</strong>Controller<strong>RD</strong> seriesRS-232CPCPrinterTo make it easier to read the valueson the display, the last digit onthe main display can be deleted,or the decimal point can beshifted to a different position.Selectable input range and calculationof two-channel analoginput valuesApplicationUseful when linearity for a targetcannot be obtained, orwhen intentionally performingmeasurements beyond thespecified measuring range.ApplicationUseful for measuring heightdifference of targets on avibrating line, or for measuringthe number of teeth on a gearwith eccentricity.ApplicationUseful for removing noisefrom sensor data, for measuringtargets on a vibrating line,or for measuring the eccentricityof a gear.Linearizer functionCorrecting measurement data fortargets of different materialsHigh-pass filterCounting number of teeth on agear with eccentricityLow-pass filterMeasurement of target thickness onpressing line or other vibrating linesOffset and auto-zerofunctionsThe offset value (reference value)can be set to the desired value.After the offset value is stored,pressing the auto-zero key willdisplay the measured value as theactual dimensions of the currenttarget. With the <strong>RD</strong>, tolerance limitscan also be set to the actualallowable dimensions.ApplicationActual target dimensions can bedisplayed, making visual checkseasier. This results in increasedefficiency for setting or checking.Automatic peak/bottomdetection functionThe <strong>RD</strong> will detect if the inputvalue falls below the peak value orrises above the bottom value by aspecified margin.ApplicationUseful for detecting a camshaftposition or for targets with eccentricity.Auto-peak/auto-bottomfunctionWithout the normally requiredsynchronous signal, the latestpeak or bottom value is alwaysretained.ApplicationUseful for controlling the peak orbottom values of all products ineach lot, or of all products manufacturedeach day.The input range can be switchedto ±5 VDC, ±10 VDC, or 4 to 20mA. The <strong>RD</strong> series has “X + Y”and “X - Y” functions, which areexcellent for measuring targetthickness or height difference.AXYFive-level tolerance settingsFive tolerance levels (HH, HI, GO,LO, and LL) can be set, and up toeight sets of tolerances can bestored. The current set of tolerancescan be easily switched toanother set, using an external signal,during target changeover. Inaddition, the current tolerance valuescan be displayed with a singletouch. The hysteresis for the tolerancescan also be set.RS-232C interface (<strong>RD</strong>-50R)The RS-232C serial port is convenientfor transmitting measuredvalues to a PLC or PC, or toremotely operate the <strong>RD</strong>-50R.. . . and moreThickness=A– (X+Y)


<strong>RD</strong> <strong>Series</strong>SpecificationsModel <strong>RD</strong>-50E <strong>RD</strong>-50RMeasurement functionDC voltage measurement, DC current measurementMeasuring range±5 VDC, ±10 VDC, 4 to 20 mA DC (selectable)Display range -19999 to +39999±0.03% of F.S. (at ±5 VDC range)Measuring accuracy±0.03% of F.S. (at ±10 VDC range)±0.05% of F.S. (at 4 to 20 mA DC range)Impedance1 MΩ (for voltage input), 350 Ω (for current input)InputSystemSingle-endedNumber of inputs 2Sampling rate2000 c/sDisplay rate20 c/sControl inputSynchronousHold-resetAuto-zeroExternal settingNPN open-collector or non-voltage contact signalTolerance setting8 programs selectable (4 levels per program)Control outputSignal5 x NPN open-collector (HH, HI, GO, LO, LL) : 100 mA (40 V max.)Response time 1 ms (when average number 1)Off-delay time60 ms (ON/OFF selectable)Voltage±10 VDC<strong>Analog</strong> voltageoutputImpedance100 ΩResponse time 1 ms (when average number 1) 1.InterfaceControl input by NPN open-collector or non-voltagecontact signalData output and control input through RS-232CPower supply 24 VDC±10%, Ripple (p-p): 10%Current consumption270 mA max.Ambient temperature0 to +50˚CRelative humidity 35 to 85%Vibration10 to 55 Hz, 1.5 mm double amplitude in X, Y, and Z directions, 2 hours respectivelyWeightApprox. 700 g (excluding fittings)1. Requires 1.5 ms every second during sefl-compensation sequence to prevent temprerature fluctuation.Dimensions<strong>RD</strong>-50E/<strong>RD</strong>-50R12Panel thickness: 0 to 6.5Panel cutout110 min.Unit: mm92 +0.8– 0112 9584 90140 min.92 +0.8– 0The panel thicknessshould be 6.5 mm or less.Mounting bracket52.2 14142963156ø116440M4 x P0.7Visit our website for other <strong>Keyence</strong> products atSpecifications are subject to change without notice.Boston OfficePhone:781-453-2244 Fax:781-453-2255New Jersey OfficePhone:201-291-4000 Fax:201-291-8860Pennsylvania OfficePhone:610-768-8993 Fax:610-337-1067Charlotte OfficePhone:704-423-0070 Fax:704-423-0066KEYENCE CORPORATION OF AMERICACorporate Office50 Tice Blvd., Woodcliff Lake, NJ 07677, U.S.A.Atlanta OfficePhone:770-951-1222 Fax:770-951-1958Tampa OfficePhone:813-998-9886 Fax:813-998-9887Cleveland OfficePhone:216-464-7530 Fax:216-464-7540Columbus OfficePhone:614-799-3400 Fax:614-799-3401Cincinnati OfficePhone:513-554-1227 Fax:513-554-1229Michigan OfficePhone:734-591-9922 Fax:734-591-1722Indianapolis OfficePhone:317-843-2616 Fax:317-843-2647Chicago OfficePhone:847-969-0001 Fax:847-969-0453Minneapolis OfficePhoenix OfficePhone:952-924-9779 Fax:952-249-9143 Phone:602-225-2400 Fax:602-225-2425St. Louis OfficePortland OfficePhone:314-275-9174 Fax:314-275-9175 Phone:503-699-0500 Fax:503-699-8400Texas OfficeNorthern California OfficePhone:972-733-6790 Fax:972-733-6791 Phone:925-225-1550 Fax:925-225-1440Denver OfficeLos Angeles OfficePhone:303-756-5242 Fax:303-756-8301 Phone:310-851-8635 Fax:310-851-8681© KEYENCE CORPORATION, 1994 <strong>RD</strong>-C 1298 3m