Flat roof fastening systems for aerated concrete deck ... - EPRO

epro.adria.si

Flat roof fastening systems for aerated concrete deck ... - EPRO

Austenitic stainless steel fastenerFlat roof fastening systems for aerated concrete deckisofast ® LBS-S-T25isofast ® LBS-S-T25Technical informationApplicationFor the fastening of waterproof membrane and insulation to aerated concrete with min. quality class P 3.3 (DIN 4223-1).For aerated concrete substrate applications we recommend the use of fasteners manufactured from austenitic stainlesssteel, grade AISI 304, European Standard 1.4301 due to the high moisture absorption capability of this material.5MaterialFastener LBS-S-T25Austenitic stainless steel, gradeAISI 304, European Standard1.4301, grade A2Stress plates ID-70x70 / IF/IG-C-82x40 / IRD-82x40Steel 1,0 mm, zinc platedResistance at 15 cycles Kesternichtest according to ETAG 006 - D.3.1.and FM requirementsTools and accessoiresRecommendation for installation Power screwdriver- 300 - 700 rpm- min. 500 W Battery tool- 300 - 700 rpm- approx. 18V- Battery with approx. 2,5 Ah Do not us a percussion tool.Stress platesID-70x70IF/IG-C-82x40IRD-82x40 Stress plate for insulation,hole diameter 7,5 mm Stress plate for membraneand insulation on hard subrates,hole diameter 7,5 mm Stress plate for membraneand insulation,hole diameter 7,5 mmTools and accessories can be found in chapter 105.201/2013


Flat roof fastenings system for aerated concrete deckAustenitic stainless steel fastenerisofast ® LBS-S-T25Order informationdT25 Ø 9,6 mmLKL clamping length | M magazine loaded | d thread diameter | L Length | t thickness of structure | All measures in mmOrder codeLBS-S-T25- 8,0x 65Product / Application Approval Type d L KL Application rangeStainless steelETA 08/0262LBS-S-T25-LBS-S-T25-LBS-S-T25-LBS-S-T25-LBS-S-T25-LBS-S-T25-LBS-S-T25-8,0x8,0x8,0x8,0x8,0x8,0x8,0x6585105125145165185525456585105125KLmax.SdSd (Setting depth): min. 60 mmInsulation compressive strength min. 0,07 N/mm 2 .L5Availability on request.Please consult your SFS representative for furtherinformation.Stress platesID-70X70IF/IG-C-82X40IRD-82X40IDIF/IG-CIRDTools and accessories can be found in chapter 1001/20135.3


Carbon steel fastenerFlat roof fastening systems for aerated concrete deckisofast ® LBS-T25isofast ® LBS-T25Technical informationApplicationFor the fastening of waterproof membrane and insulation to aerated concrete with min. quality class P 3.3 (DIN 4223-1).5MaterialFastener LBS-T25Case hardened carbon steelDurocoat ® corrosion protection:Resistance at 15 cycles Kesternichtest according to ETAG 006 - D.3.1.and FM requirementsEnvironment friendly, free ofchromium VIStress plates ID-70x70 / IF/IG-C-82x40 / IRD-82x40Steel 1,0 mm, zinc platedResistance at 15 cycles Kesternichtest according to ETAG 006 - D.3.1.and FM requirementsTools and accessoiresRecommendation for installation Power screwdriver- 300 - 700 rpm- min. 500 W Battery tool- 300 - 700 rpm- approx. 18V- Battery with approx. 2,5 Ah Do not us a percussion tool.Stress platesID-70x70IF/IG-C-82x40IRD-82x40 Stress plate for insulation,hole diameter 7,5 mm Stress plate for membraneand insulation on hard subrates,hole diameter 7,5 mm Stress plate for membraneand insulation,hole diameter 7,5 mmTools and accessories can be found in chapter 105.401/2013


Flat roof fastenings system for aerated concrete deckCarbon steel fastenerisofast ® LBS-T25Order informationdT25 Ø 9,6 mmLKL clamping length | M magazine loaded | d thread diameter | L Length | t thickness of structure | All measures in mmOrder codeLBS-T25- 8,0x 65Product / Application Approval Type d L KL Application rangeCarbon steelETA 08/0262LBS-T25-LBS-T25-LBS-T25-LBS-T25-LBS-T25-LBS-T25-LBS-T25-8,0x8,0x8,0x8,0x8,0x8,0x8,0x6585105125145165185525456585105125KLmax.SdSd (Setting depth): min. 60 mmInsulation compressive strength min. 0,07 N/mm 2 .L5Stress platesID-70X70IF/IG-C-82X40IRD-82X40IDIF/IG-CIRDTools and accessories can be found in chapter 1001/20135.5


Carbon steel fastenerFlat roof fastening systems for aerated concrete deckisotak ® LBS-T25 / R45isotak ® LBS-T25 / R45Technical informationApplicationFor the fastening of waterproof membrane and insulation to aerated concrete with min. quality class P 3.3 (DIN 4223-1).5MaterialFastener LBS-T25Case hardened carbon steelDurocoat ® corrosion protection:Resistance at 15 cycles Kesternichtest according to ETAG 006 - D.3.1.and FM requirementsEnvironment friendly, free ofchromium VI R45High quality polypropylene, PPTools and accessoiresZA¼“-M6-300/750 / T25-32-M6-RINGZH-11-RINGRecommendation for installationZA¼“-M6-300/750T25-32-M6-RINGZH-11-RING Power screwdriver- 300 - 700 rpm- min. 500 W Battery tool- 300 - 700 rpm- approx. 18V- Battery with approx. 2,5 Ah For the manual installation of ofisotak ® fasteners and sleeves Do not us a percussion tool.Tools and accessories can be found in chapter 105.801/2013


Flat roof fastenings system for aerated concrete deckCarbon steel fastenerisotak ® LBS-T25 / R45Order informationdT25 Ø 9,6 mmLLKL clamping length | M magazine loaded | d thread diameter | L Length | t thickness of structure | All measures in mmOrder codeLBS-T25- 8,0x 105Product / Application Approval Type d L KL Application rangeCarbon steelLBS-T25-LBS-T25-LBS-T25-LBS-T25-LBS-T25-8,0x8,0x8,0x8,0x8,0x105125145165185KLETA 08/0262min. 15 mmSd5Sd (Setting depth): min. 60 mmInsulation compressive strength min. 0,07 N/mm 2 .PlasticETA 08/0262RRRRRRRRRRRRRRRRRRR45x45x45x45x45x45x45x45x45x45x45x45x45x45x45x45x45x45x45x15356585105135165185195225255285325365405485565645705KL see combination tableTools and accessories can be found in chapter 1001/20135.9


Combination tableR45 / LBS-T25 / LBS-S-T25Flat roof fastening systems for aerated concrete deckSleeve length 3655Selection of the correct fastener and sleeve combinationCombination sleeve R45 and LBS-T25-8,0xLLBS-S-T25-8,0xLKL (mm)KL500490480470460450440430420410400390380min. 15 mmR45 LBS-T25-8,0xL370360LBS-S-T25-8,0xL350340min. 60 mm33032031030029028027026025024023022021020019018017016015014013012011010090807060504030Sleeve length 65Sleeve length 35Sleeve length 15Sleeve length 165Sleeve length 135Sleeve length 105Sleeve length 85Sleeve length 405Sleeve length 485Sleeve length 185Sleeve length 325Sleeve length 285Sleeve length 255Sleeve length 225Sleeve length 195Sleeve R45xL125 125 145105 105105 125 105 125125 105 105 125 145105 125 105 125125105 105 125 125105 105125 145105 125 105 125 145105 105 125125 105 105 125105 105 125 125 145105 105105125 125 145 145105 105 125 125 145 145105 105125 125 145105 105125 125 145 145105 105 125 125 145 145 165 165 185Fastener LBS-T25-8xLLBS-S-T25xLCalculation: Roof buildup (KL) - Sleeve length (L) + 75 mm = min. length Type of fastenerExample: 100 mm - 85 mm + 75 mm = 90 mm -> LBS-T25-8x1055.1001/2013