Views
3 years ago

Download

Download

SHModel SH−221

SHModel SH−221 SH−241 SH−261 SH−641 SH−661SystemTemp. performance *1Humid.performance *1ConstructionTemp. rangeTemp. fl uctuationTemp. gradient /Temp. variation in spaceTemp.rate ofchangeHeat up time20 to 150(4 to 302)Balanced Temperature & Humidity Control system (BTHC system)40 to 150(40 to 302)60 to 150(76 to 302)40 to 150(40 to 302)60 to 150(76 to 302)0.3 (20 to 100) 0.3℃ (40 to 100℃) 0.3℃ (60 to 100℃) 0.3℃ (40 to 100℃) 0.3℃ (60 to 100℃)0.5 (100.1 to 150) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃)2.5℃ (20 to 100℃) 2.5℃ (40 to 100℃) 2.5℃ (60 to 100℃) 2.5℃ (40 to 100℃) 2.5℃ (60 to 100℃)4.0℃ (100.1 to 150℃) 4.0℃ (100.1 to 150℃) 4.0℃ (100.1 to 150℃) 4.0℃ (100.1 to 150℃) 4.0℃ (100.1 to 150℃)Heat up rate 3.2 /min. 3.2 /min. 3.2 /min. 2.9 /min. 2.9 /min.Pull down rate 2.1 /min. 2.1 /min. 2.1 /min. 1.7 /min. 1.7 /min.Temp. extremeachievement timePull down timeFrom 20 to 150within 55 min.From 20 to 20within 20 min.From 40 to 150within 60 min.From 20 to 40within 50 min.From 60 to 150within 70 min.From 20 to 60within 70 min.From 40 to 150within 70 min.From 20 to 40within 60 min.From 60 to 150within 80 min.From 20 to 60within 90 min.Lowest attainable temp. 20 40 60 40 60Humid. range 30 to 95rh (Refer to diagram on page 9)Humid. fl uctuationHeaterHumidifi erRefrigeration unit3.0rhNichrome strip wire heaterSheathed heaterSystem Mechanical single-stage refrigeration system Mechanical cascade refrigeration systemCoolerPlate fi n coolerRefrigerator Hermetically sealed compressor, Air-cooled condenser, Expansion mechanism: Capillary tube systemRefrigerator capacity 400W [Unit 1: 400W 1, Unit 2: 400W 1]Refrigerant R404A R23, R404ACapacity 22.5 L 64 LChamber total loadresistance20 kgInside dimensionsmm (inch) *2Outside dimensionsmm (inch) *2W300H300D250(W11.81H11.81D9.84)W440H630D695(W17.32H24.80D27.36)W440H690D785(W17.32H27.18D30.91)W400H400D400(W15.75H15.75D15.75)W540H730D920(W21.26H28.74D36.22)Weight 83 kg (78 for 100V type) 105 kg 130 kgAllowable ambient conditions5 to 35 (41 to 95Utility requirementsPower supply *3100V AC 150/60Hz 13.5 A 15.0 A 18.0 A115V AC 160Hz 13.0 A 14.5 A —200V AC 150/60Hz — 10.5 A220V AC 150/60Hz 8.0 A 9.5 A 10.0 A220V AC 160Hz *4 8.0 A 9.5 A 10.0 A230V AC 1φ50Hz *4 7.5 A 9.5 A 10.0 ANoise level *5 55 dB 59 dB 61 dBExhaust heat quantity 3500 kJ/h (836 kcal/h) 4000 kJ/h (955 kcal/h) 5040 kJ/h (1204 kcal/h)*1 The performance values are based on IEC 60068-3-5:2001, JTM K07:2007 for the temperature chamber, IEC 60068-3-6:2001, JTM K09:2009 for the humiditychamber. Performance fi gures are given for a 23 ambient temperature, 65% rh, rated power supply and no specimens inside the test area. However, the lowestattainable temperature is given for a max. ambient temperature of 30. Heat-up time is the achieved time from lowest temperature to highest temperature withintemperature range.*2 Excluding protrusions.*3 At ambient temperature 23. For SH-641/661, make sure to check the power capability of your installation beforehand.*4 Compliance with CE Marking.*5 Measurements are to be taken in an anechoic room at a height of 1.2m from the fl oor and a distance of 1m from the chamber front panel(ISO 1996-1:2003 _ A-weighted sound pressure level)7

SUModel SU−221 SU−241 SU−261 SU−641 SU−661SystemTemp. performance *1ConstructionTemp. rangeTemp. fl uctuationTemp. gradient /Temp. variation in spaceTemp.rate ofchangeHeat up time20 to 150(4 to 302)Balanced Temperature Control system (BTC system)40 to 150(40 to 302)60 to 150(76 to 302)40 to 150(40 to 302)60 to 150(76 to 302)0.3 (20 to 100) 0.3℃ (40 to 100℃) 0.3℃ (60 to 100℃) 0.3℃ (40 to 100℃) 0.3℃ (60 to 100℃)0.5 (100.1 to 150) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃) 0.5℃ (100.1 to 150℃)2.5℃ (20 to 100℃)4.0℃ (100.1 to 150℃)2.5℃ (40 to 100℃)4.0℃ (100.1 to 150℃)2.5℃ (60 to 100℃)4.0℃ (100.1 to 150℃)2.5℃ (40 to 100℃)4.0℃ (100.1 to 150℃)2.5℃ (60 to 100℃)4.0℃ (100.1 to 150℃)Heat up rate 3.2 /min. 3.2 /min. 3.2 /min. 2.9 /min. 2.9 /min.Pull down rate 2.1 /min. 2.1 /min. 2.1 /min. 1.7 /min. 1.7 /min.Temp. extremeachievement timePull down timeFrom 20 to 150within 55 min.From 20 to 20within 20 min.From 40 to 150within 60 min.From 20 to 40within 50 min.From 60 to 150within 70 min.From 20 to 60within 70 min.From 40 to 150within 70 min.From 20 to 40within 60 min.From 60 to 150within 80 min.From 20 to60within 90 min.Lowest attainable temp. 20 40 60 40 60HeaterRefrigeration unitNichrome strip wire heaterSystem Mechanical single-stage refrigeration system Mechanical cascade refrigeration systemCoolerPlate fi n coolerRefrigerator Hermetically sealed compressor, Air-cooled condenser, Expansion mechanism: Capillary tube systemRefrigerator capacity 400W [Unit 1: 400W 1, unit 2: 400W 1]Refrigerant R404A R23, R404ACapacity 22.5 L 64 LChamber total loadresistance20 kgInside dimensionsmm (inch) *2Outside dimensionsmm (inch) *2W300H300D250(W11.81H11.81D9.84)W440H560D695(W17.32H24.8D27.36)W440H620D785(W17.32H24.41D30.91)W400H400D400(W15.75H15.75D15.75)W540H660D920(W21.26H25.98D36.22)Weight 78 kg (73 for 100V type) 100 kg 123 kgAllowable ambient conditions5 to 35 (41 to 95Utility requirementsPower supply *3100V AC 150/60Hz 11.0 A 15.0 A 18.0 A115V AC 160Hz 10.5 A 14.5 A —200V AC 150/60Hz — 10.5 A220V AC 150/60Hz 7.0 A 9.5 A 10.0 A220V AC 160Hz *4 7.0 A 9.5 A 10.0 A230V AC 150Hz *4 6.5 A 9.5 A 10.0 ANoise level *5 55 dB 59 dB 61 dBExhaust heat quantity 3500 kJ/h (836 kcal/h) 4000 kJ/h (955 kcal/h) 5040 kJ/h (1204 kcal/h)*1 The performance values are based on IEC 60068-3-5:2001, JTM K07:2007 for the temperature chamber. Performance fi gures are given for a 23 ambient temperature,65%rh, rated power supply and no specimens inside the test area. However, the lowest attainable temperature is given for a max. ambient temperature of 30 .Heat-up time is the achieved time from lowest temperature to highest temperature within temperature range.*2 Excluding protrusions.*3 At ambient temperature 23. For SU-641/661, make sure to check the power capability of your installation beforehand.*4 Compliance with CE Marking.*5 Measurements are to be taken in an anechoic room at a height of 1.2m from the fl oor and a distance of 1m from the chamber front panel(ISO 1996-1:2003 _ A-weighted sound pressure level)8

Catalogue - Xebex.jp
download product brochure @ specs
Click here to download Roll of Honour 2013 - Competenz
Free Access Temperature (& Humidity) Chamber - MB Electronique
Download Mikro 220R PDF Datasheet - Hettich Centrifuges UK
Free to download, our Personal Development checklist - Chartered ...