13.07.2015 Views

Avanta suggested schematics

Avanta suggested schematics

Avanta suggested schematics

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

AVANTA PLUS System Option 3Typical “S” plan Heating and DHW using 230v controls2 ChannelTime clockRoom Stat230v SupplyWiring Centre22mmReturnCondensateHTG Zone Valvec/w end switches22mmFlow22mm GasDHW Zone Valvec/w end switchesCylinder StatAVS0001L641 CylinderThermostat2CCall1WiringCentre9 10873 4 5 6ST699 ControlLNOFFONOFFONDHWHTGClock2Call311 2T6360/T4360Room ThermostatV4043HDHW Zone ValveEnd SwitchClose on fullyopenRemove exist links123X2L4V4043HHTG Zone ValveEnd SwitchCloseonfullyopenLNEEN5X6LN 230vPower Supply230v - 1 - 503 amp Switched SpurBoilerAVW00017

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!