GeneralSpecifications<strong>Laser</strong> <strong>Turbidity</strong> <strong>Meter</strong><strong>TB600G</strong>GS 12E7A1-E• GeneralWith the recent development in membrane filtrationtechnologies, organic filters have come into practicaluse as a high-performance treatment method fordrinking water. In the use of this filter treatment, filterbreakage due to a long-term operation is of concern,which makes constant monitoring of filter performancecritical and essential. This is where a turbidity meterthat can detect a cut of hollow thread and breakage ofpinholes is required.The <strong>Laser</strong> <strong>Turbidity</strong> <strong>Meter</strong> <strong>TB600G</strong> detects intensityvariations of the transmitted light of semiconductorlaser when suspended materials pass through the celland converts them into turbidity.With the semiconductor laser, the <strong>TB600G</strong> can detectparticles of even 0.1µm, providing the instrument withhigh sensitivity which is required to detect filter breakageand monitor filter conditions, especially in themembrane filtration method.Furthermore, the <strong>TB600G</strong> can be used as a turbiditymeter installed at outflows from filtration reservoirswherethe water quality control is required under “the ProvisionalGuideline for Cryptosporidium Compliance.”• Features- Based on the semiconductor laser method- High-sensitivity measurement in 0.0001-degree- Not affected by colors of water samples, particlesizes, and components- Arrest the generation of air bubbles by utilizing thepressure-type defoaming tank- Simple installation through easy wiring and piping,aided by a self-supporting stanchion where the turbiditymeter is mounted.• System ConfigurationWatersampleDefoamingtankFlowmeterwith valveConverterDetectorPower supply100 to 240V ACOutput4 to 20mA DC,RS-232CContact output• General SpecificationMeasured objects: Detection of membrane breakageon membrane filtration treatment andmeasurement of turbidity at outflowsfrom filtration reservoirs at drinking watertreatment plantsMeasuring method: Semiconductor laser methodMeasuring range: 0.0000 to 2.0000 mg/l or NTUMeasurement cycle: Selectable from among 6seconds/1 minute/10 minutes. An averageof the selected time is indicated. (Data isupdated every six seconds.)Output range: Specified setting with a minimum spanof 0 to 0.1 mg/l or 0 to 0.1 NTUOutput signal: 4 to 20 mA DC (Maximum loadresistance: 550 Ω), RS-232CCommunication:Method:Unilateral communication start-stopsynchronizing methodTransmission code: ASCIITransmission speed: 9600 BPSData length: 8 bitStop bit: 2 bitParity check: NoneDrainF01.aiYokogawa Electric Corporation2-9-32, Nakacho, Musashino-shi, Tokyo, 180-8750 JapanTel.: 81-422-52-5617 Fax.: 81-422-52-6792GS 12E7A1-E©Copyright Jul. 19992nd Edition Nov. 2007


• External DimensionsWithout sampling systemConverter1 to 10 (Panel thickness)Nominal 50A pipeUnit: mm4-ø6 (Surface mounting)28098.5126.5 (Surfacemounting)8 31 31 31 31 1057.329 24 36228136.5 54.5Cable connection5-ø27(with rubber plug)111Surfacemounting holes190195Grounding terminalM4F04.aiDetector310250238Mounting bracket(option: /R)10Rc1/4Water sample outlet28Nominal 50A pipe8-ø10 holes4737.59032.575 70130160220120 7065 554-ø4.5 holes(detector mounting holes)Rc1/4Water sample inletF05.aiAll Rights Reserved. Copyright © 1999, Yokogawa Electric CorporationGS 12E7A1-ENov.01,2007-00


With sampling systemUnit: mmMaintenance space350 (100 )4-ø15 holes Approx.for anchor200bolts(600)938025010020490 (20)530FrontApprox.200ConverterApprox.500CVDetectorDefoamingtankP1NV1DG1BV2DTFR1BV1Approx. 1410Approx. 870Water sampleinlet(VP16)**15020490 (20)5304-ø15 holes(for anchor bolts)100 350 (100)150*38555070 50*: For rear piping installationDrain port(VP40)F06.aiAll Rights Reserved. Copyright © 1999, Yokogawa Electric CorporationGS 12E7A1-ENov.01,2007-00


Pressure-type defoaming tank (with mounting brackets), K9725WAUnit: mmPressure gauge(scale: 0 to 500 kPa)Needle valve(material: SUS316)35145Approx. 332 Approx. 127ø6/ø4Polyethylene tubeø6/ø4Polyethylene tube5011014015154-ø6.2 holesø10/ø8Polyethylene tubeF07.aiControl valve, B1000EUAir outlet5496 to 103ø6152ø70ScaleKnob562-M4 screws,45 6 deep4445(for mounting)Nut (for panel mounting)10(panel cut: ø13,Drain outletpanel thickness: max. 14.5)2-M4 screws,6 deep(for mounting)3-Rc1/4F08.aiAll Rights Reserved. Copyright © 1999, Yokogawa Electric CorporationGS 12E7A1-ENov.01,2007-00


INQUIRY SHEET FOR <strong>TB600G</strong> LASER TURBIDITY MEASURING SYSTEMThank you for inquiring about our turbidity measuring system. Please fill in the following information or put a tick nextto the relevant item(s).1. General Information(1) Customer/Company name : _____________________________________________(2) Contact person : ___________________ Section: _________________ Phone: _______________(3) Plant name : _____________________________________________(4) Process to be measured : _____________________________________________(5) Measurement objective : □ Indication □ Recording □ Alarm □ Control(6) Power supply : _____________________ V AC, ___________________ Hz2. Measurement Conditions(1) Water sample temperature : Max. Min. Normal; [°C](2) Water sample pressure : Max. Min. Normal; [kPa](3) Flow rate : Max. Min. Normal; [l/min](4) Presence of slurry or contamination : □ No □ Yes(5) Water sample composition : _______________________________________________________(6) Others : _______________________________________________________3. Installation(1) Ambient temperature : _______________________________________________________(2) Location : □ Indoors _______________________________________________(3) Others : _______________________________________________________4. Specification Requirements(1) Measuring range : □ to mg/l(2) Transmission output : □ 4 to 20mA DC □ RS-232C(3) System component used : □ <strong>Laser</strong> turbidity meter □ Sampling system(4) Other informationAll Rights Reserved. Copyright © 1999, Yokogawa Electric CorporationSubject to change without notice.GS 12E7A1-ENov.01,2007-00