13.07.2015 Views

ABB industrial drives ACS880, single drives 0.55 ... - VAE ProSys sro

ABB industrial drives ACS880, single drives 0.55 ... - VAE ProSys sro

ABB industrial drives ACS880, single drives 0.55 ... - VAE ProSys sro

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Summary of features and optionsPower and voltage range230 V400 V500 V690 VOrderingcode<strong>ACS880</strong>-01R1 to R9<strong>ACS880</strong>-07R6 to R11kW kW kW<strong>0.55</strong> to 75<strong>0.55</strong> to 250<strong>0.55</strong> to 2504 to 25045 to 50045 to 56045 to 630<strong>ACS880</strong>-07n×R8i400 to 1400500 to 1400560 to 2800EMC filtersEMC 1 st environment, unrestricted distribution (category C2) E202 2) 2) –EMC 2 nd environment, unrestricted distribution (category C3) E200 3) 3) –EMC 2 nd environment, unrestricted distribution (category C3) E201 4) 4) –EMC 2 nd environment, unrestricted distribution (category C3) E210 – 5)Line filterAC or DC chokeOutput filtersCommon mode filter E202 –du/dt filtersE205Braking (see braking unit table)Brake chopper D1506) 7)Brake resistor D151 7)Rectifier bridge12-pulse A004 – –Line side apparatusaR line fuses –Main switch –Line contactor F250 –Air circuit breaker F255 – – 8)Earthing switch F259 – –Cabinet optionsCabinet heater (ext. supply) G300 –Output for motor heater (ext. supply) G313 –Customized options P902 –Safety optionsSafe torque off (STO)FSO-11, without encoder: Safe stop 1 (SS1)Q973FSO-11, without encoder: Safely-limited speed (SLS)Q973FSO-11, without encoder: Safe brake control (SBC)Q973FSO-11, without encoder: Safe maximum speed (SMS)Q973FSO-11, without encoder: Safe stop emergency (SSE)Q973Prevention of unexpected startup with safety relay Q957 –Prevention of unexpected startup with FSO-11 Q950 –9) 9)Emergency stop, category 0 with opening the main contactor/Q951 –breaker, with safety relayEmergency stop, category 1 with opening the main contactor/Q952 –breakerEmergency stop, category 0 with STO, with safety relay Q963 –Emergency stop, category 1 with STO, with safety relay Q964 –Emergency stop, configurable category 0 or 1 with opening the main Q978 –9) 9)contactor/breaker, with FSO-11Emergency stop, configurable category 0 or 1 with STO and FSO-11 Q979 –9) 9)Safely-limited speed without encoder, with FSO-11 –9) 9)Earth fault monitoring, earthed mainsEarth fault monitoring, unearthed mains Q954 –ATEX thermal motor protection –9) 9)ApprovalsCEUL, cUL C121 10)CSA C13413) 11) 11)EAC/GOST R 12)RoHSC-TickMarine type approvals 11) – –TÜV nord certificate for safety functions9) 9)StandardSelectable option, with plus codeSelectable option, external, no plus code– Not availableNotes1)Without control panel, 0J4002)Earthed network,frame sizes R1 to R9, 380 to 500 V3)Earthed network, frame sizes R6 to R9, 380 to 500 V4)Unearthed network, frame sizes R6 to R9 380 to 500 V,frame sizes R7 to R9, 690 V5)Earthed/unearthed network, frame sizes R10 to R11(380 to 500 V)6)Frame sizes R5 to R9 as selectable option, built-in7)2×R8i8)2×D8T to 4×D8T9)Check availability from local <strong>ABB</strong>10)Frame sizes R10 to R11 pending11)Pending12)EAC will replace GOST R13)CSA pending 230 V (R4 to R8)Catalog | <strong>ABB</strong> <strong>industrial</strong> <strong>drives</strong> <strong>ACS880</strong> <strong>single</strong> <strong>drives</strong> 35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!