<strong>T60si</strong>ELECTRICAL REQUIREMENTSRCD(can be part ofconsumer unit)Fuse ormcbWARNINGTHIS APPLIANCE MUST BE EARTHEDThe installation, supply cable and circuitprotection must conform with IEE wiringregulations and be sufficient for theamperage required.The following notes are for guidance only:1 The shower must only be connected to a230-240V ac supply. If you are installing a showerwith a kilowatt rating above 9kW, it is advisableto contact the local electricity supply company.1.1 The electrical rating of the shower is shownon the rating label (fig.2) within the unit.80A or 100Amain switchConsumerunitMetertailsPull cordisolating switchFig.2MeterShowerunitFig.3 schematic of installation circuitIncomingsupplyfuse2 Before making any sort of electricalconnection within the installation, ensure that noterminal is live. If in any doubt, switch off thewhole installation at the consumer unit.3 The shower must be connected to its ownindependent electrical circuit. IT MUST NOT beconnected to a ring main, spur, socket outlet,lighting circuit or cooker circuit.3.1 The electrical supply must be adequate forthe loading of the unit and existing circuits.4 Check your consumer unit (main fuse box)has a main switch rating of 80A or above and thatit has a spare fuse way which will take the fuse ormcb necessary for the shower (fig.3).4.1 If your consumer unit has a rating below80A or if there is no spare fuse way, then theinstallation will not be straight forward and mayrequire a new consumer unit serving the house orjust the shower.4.2 You will need to contact the local electricitycompany. They will check the circuit and carry outwhat is necessary. They will also check the mainbonding.5 The earth continuity conductor of theelectrical installation must be effectivelyconnected electrically to all exposed metal parts ofother appliances and services in the room inwhich the shower is to be installed, to conform tocurrent IEE regulations.Table ACIRCUIT PROTECTIONunitcartridgerating mcb fuse7.0kW 30/32A 30A7.5kW 32A 35A8.0kW 40A 35A8.5kW 40A 45A9.0kW 40A 45A9.5kW 40/45A 45A10.5kW 45A 45A4

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!