13.07.2015 Views

Model F1 Residential Sprinklers - Reliable Automatic Sprinkler Co.

Model F1 Residential Sprinklers - Reliable Automatic Sprinkler Co.

Model F1 Residential Sprinklers - Reliable Automatic Sprinkler Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SPRINKLERS FOR REPLACEMENT USE ONLY IN EXISTING SPRINKLER SYSTEMSApplication and Installation<strong>Model</strong> <strong>F1</strong> <strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong> must be installed in accordancewith NFPA 13,13D or 13R. These sprinklersare approved solely for use with indoor wet pipe sprinklersystems.<strong>Model</strong> <strong>F1</strong> Recessed <strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong> are to be installedonly as shown. The <strong>Model</strong> <strong>F1</strong> or <strong>Model</strong> F2 Escutcheonillustrated is the only recessed escutcheon tobe used with the <strong>Model</strong> <strong>F1</strong> Pendent or Horizontal Sidewall<strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong>. The use of any other recessedescutcheon will void all approvals on thesesprinklers and negate all warranties. When installing<strong>Model</strong> <strong>F1</strong> <strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong>, use the <strong>Model</strong> D <strong>Sprinkler</strong>Wrench and when installing <strong>Model</strong> <strong>F1</strong> Recessed<strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong>, use the <strong>Model</strong> GFR1 <strong>Sprinkler</strong>Wrench. Any other type of wrench may cause damageto these sprinklers.<strong>Model</strong>s <strong>F1</strong>/RES, <strong>F1</strong>/RES 2, <strong>F1</strong>/RES 16, <strong>F1</strong>/RES 18 and<strong>F1</strong>/RES 20 Pendent <strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong> shall be positionedsuch that the deflectors are within 1 to 4 inches fromthe ceiling.Finishes (1)Standard Finishes<strong>Sprinkler</strong>BronzeChrome PlatedWhite Polyester <strong>Co</strong>atedSpecial Application Finishes<strong>Sprinkler</strong>Bright BrassBlack PlatedBlack PaintOff WhiteSatin ChromeEscutcheonBrassBright Chrome PlatedWhite PaintedEscutcheonBright BrassBlack PlatedBlack PaintOff WhiteSatin Chrome. (1) Other finishes and colors are available on special order.<strong>Co</strong>nsult factory for details.Escutcheon DataRecessed <strong>Sprinkler</strong>Escutcheon<strong>Model</strong>Maintenance<strong>Model</strong> <strong>F1</strong> <strong>Residential</strong> <strong><strong>Sprinkler</strong>s</strong> should be inspectedquarterly, and the sprinkler system maintained in accordancewith NFPA 25, 13, 13D, and 13R. Do not cleansprinkler with soap and water, ammonia or any othercleaning fluids. Remove dust by using a soft brush orgentle vacuuming. Remove any sprinkler which hasbeen painted (other than factory applied) or damaged inany way. A stock of spare sprinklers should be maintainedto allow quick replacement of damaged or operatedsprinklers. Prior to installation, sprinklers should bemaintained in the original cartons and packaging untilused to minimize the potential for damage to sprinklersthat would cause improper operation or non-operation.UL Listing Category<strong>Residential</strong> <strong>Automatic</strong> <strong>Sprinkler</strong>UL Guide NumberVKKWPatentsUS. Patent No. 5,687,914 applies to the <strong>Model</strong><strong>F1</strong>/RES 18 Pendent <strong><strong>Sprinkler</strong>s</strong>.U.S. Patent No. 5,727,737 applies to the <strong>Model</strong><strong>F1</strong>/RES 3 Horizontal Sidewall <strong><strong>Sprinkler</strong>s</strong>.U.S. Patent No. 6,026,907 applies to the <strong>Model</strong><strong>F1</strong>/RES 16 Pendent <strong><strong>Sprinkler</strong>s</strong>.Ordering InformationSpecify:1. <strong>Sprinkler</strong> <strong>Model</strong>2. <strong>Sprinkler</strong> Type3. Orifice Size4. Temperature Rating5. <strong>Sprinkler</strong> Finish6. Escutcheon Finish (where applicable)7. Escutcheon <strong>Model</strong> (<strong>F1</strong>/RES 16 and 20 Only)Note:When a <strong>Model</strong> <strong>F1</strong> Recessed <strong>Residential</strong> <strong>Sprinkler</strong> isordered, sprinklers and escutcheons are packagedseparately.Adjustment(Inches)“A”(inches)Face of Fitting to Ceilingor Wall Dimension(inches)<strong>Model</strong> <strong>F1</strong>/RES Pendent F21 25 163 16- 11 16<strong>Model</strong> <strong>F1</strong>/RES 2 Pendent F21 25 163 16- 11 16<strong>Model</strong> <strong>F1</strong>/RES 18 Pendent F21 25 163 16- 11 16<strong>Model</strong> <strong>F1</strong>/RES HSW F21 21 9 16<strong>Model</strong> <strong>F1</strong>/RES 3 HSW F21 2 1 9 163 16- 11 163 16- 11 16<strong>Model</strong> <strong>F1</strong>/RES 16 Pendent <strong>F1</strong> or3 4 ¾3 16- 15 16<strong>Model</strong> <strong>F1</strong>/RES 20 Pendent F21 215 163 16- 11 16The equipment presented in this bulletin is to be installed in accordance with the latest pertinent Standards of the National Fire Protection Association, Factory MutualResearch <strong>Co</strong>rporation, or other similar organizations and also with the provisions of governmental codes or ordinances whenever applicable.Products manufactured and distributed by <strong>Reliable</strong> have been protecting life and property for over 80 years, and are installed and serviced by the most highly qualified andreputable sprinkler contractors located throughout the United States, Canada and foreign countries.Manufactured byThe <strong>Reliable</strong> <strong>Automatic</strong> <strong>Sprinkler</strong> <strong>Co</strong>., Inc.(800) 431–1588 Sales Offices(800) 848–6051 Sales Fax(914) 668–3470 <strong>Co</strong>rporate Officeswww.reliablesprinkler.com Internet AddressRecycledPaperRevision lines indicate updated or new dataE.G. Printed in USA 08/02 P/N 9999970030

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!