13.07.2015 Views

BD LSR Fortessa Standard Operation Protocol --- Turn on and turn ...

BD LSR Fortessa Standard Operation Protocol --- Turn on and turn ...

BD LSR Fortessa Standard Operation Protocol --- Turn on and turn ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<str<strong>on</strong>g>BD</str<strong>on</strong>g> <str<strong>on</strong>g>LSR</str<strong>on</strong>g> <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g> <str<strong>on</strong>g>St<strong>and</strong>ard</str<strong>on</strong>g> <str<strong>on</strong>g>Operati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>Protocol</str<strong>on</strong>g>--- <str<strong>on</strong>g>Turn</str<strong>on</strong>g> <strong>on</strong> <strong>and</strong> <strong>turn</strong> off system (experienced user <strong>on</strong>ly)<str<strong>on</strong>g>Turn</str<strong>on</strong>g> <strong>on</strong> system:• Refill sheath tank <strong>and</strong> empty waste tank if necessary.• Please make sure all tubing are c<strong>on</strong>nected properly <strong>on</strong> sheath tank <strong>and</strong> wastetank.• <str<strong>on</strong>g>Turn</str<strong>on</strong>g> <strong>on</strong> main switch of <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g> (wait for at least 20min before CST)• Stabilize fluidics: load 3ml of H2O then set “RUN” <strong>and</strong> “LO”.• <str<strong>on</strong>g>Turn</str<strong>on</strong>g> <strong>on</strong> computer <strong>and</strong> log in with Administrator• Unplug the internet cable (blue color)• Double click Cytometer Status <strong>and</strong> <str<strong>on</strong>g>BD</str<strong>on</strong>g> FACS Diva Software ic<strong>on</strong>s <strong>on</strong> desktop• Remove air bubbles from the sheath filter.• Log into FACS Diva software with your own login name <strong>and</strong> password.• The system is ready to use when it shows “Cytometer c<strong>on</strong>nected”• Please refer to SOP of CST if CST is needed.• Rec<strong>on</strong>nect the internet cable for data transfer.<str<strong>on</strong>g>Turn</str<strong>on</strong>g> off system:• Make sure the proper cleaning procedure has been completed.• Log out Diva software.• Quite Diva software <strong>and</strong> close cytometer status window.• <str<strong>on</strong>g>Turn</str<strong>on</strong>g> off computer.• <str<strong>on</strong>g>Turn</str<strong>on</strong>g> off main switch of <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g>.• Refill sheath tank.• Empty waste tank.


<str<strong>on</strong>g>BD</str<strong>on</strong>g> <str<strong>on</strong>g>LSR</str<strong>on</strong>g> <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g> <str<strong>on</strong>g>St<strong>and</strong>ard</str<strong>on</strong>g> <str<strong>on</strong>g>Operati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>Protocol</str<strong>on</strong>g>--- CST (experienced user <strong>on</strong>ly)• Click “Cytometer” > “CST” in Diva Software• Prepare CST beads (350ul FACS flow + 1 drop of CST beads)Note: please vortex CST beads before use <strong>and</strong> put CST beads bottleback to Fridge immediately after use.• Label CST beads tube with date <strong>and</strong> “CST” <strong>and</strong> Lot Number.• Press “RUN” <strong>and</strong> “LO” <strong>on</strong> Fluid c<strong>on</strong>trol panel.• Check the beads lot number in Diva to make sure it is the same withthe beads you prepared.• Click “run” in Diva software.• CST will take about 7-10min. Please do not let CST beads run out.• Unload CST beads tube when finish <strong>and</strong> reload H2O tube.• Click “File” > “Exit”.If CST is not passed, please try the following steps <strong>and</strong> try CST again:1. Prepare <strong>on</strong>e tube of 2ml FACS Rinse2. Prime X3 with FACS Rinse3. Run 10 min at “HI” flow rate4. Prime X1 with DI H2O5. Run CST again


<str<strong>on</strong>g>BD</str<strong>on</strong>g> <str<strong>on</strong>g>LSR</str<strong>on</strong>g> <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g> <str<strong>on</strong>g>St<strong>and</strong>ard</str<strong>on</strong>g> <str<strong>on</strong>g>Operati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>Protocol</str<strong>on</strong>g>--- Empty Waste Tank• Verify that the flow cytometer is in st<strong>and</strong>by mode. Press theSTNDBY butt<strong>on</strong> <strong>on</strong> the c<strong>on</strong>trol panel if necessary.• Click “Cytometer” > “st<strong>and</strong>by” in Diva Software.• Disc<strong>on</strong>nect the orange waste tubing <strong>and</strong> the black level sensorline from the waste c<strong>on</strong>tainer.• Take the waste tank to the sink.• Remove the lid of waste tank.• Empty the waste c<strong>on</strong>tainer.• Add approximately 0.5-1L of bleach to the waste c<strong>on</strong>tainer <strong>and</strong>tighten the lid of it.• Rec<strong>on</strong>nect the orange waste tubing <strong>and</strong> level sensor line.• Rec<strong>on</strong>nect Diva software with workstati<strong>on</strong> by click “Cytometer”> “C<strong>on</strong>nect”


<str<strong>on</strong>g>BD</str<strong>on</strong>g> <str<strong>on</strong>g>LSR</str<strong>on</strong>g> <str<strong>on</strong>g>Fortessa</str<strong>on</strong>g> <str<strong>on</strong>g>St<strong>and</strong>ard</str<strong>on</strong>g> <str<strong>on</strong>g>Operati<strong>on</strong></str<strong>on</strong>g> <str<strong>on</strong>g>Protocol</str<strong>on</strong>g>--- Refill the sheath c<strong>on</strong>tainer• Verify that the flow cytometer is in st<strong>and</strong>by mode. Press the STNDBYbutt<strong>on</strong> <strong>on</strong> the c<strong>on</strong>trol panel if necessary.• Click “Cytometer” > “st<strong>and</strong>by” in Diva Software• Disc<strong>on</strong>nect the air line (green) <strong>and</strong> fluid line (Blue) from the sheathc<strong>on</strong>tainer.• Depressurize the sheath c<strong>on</strong>tainer by pulling up <strong>on</strong> the vent valve.• Remove the sheath c<strong>on</strong>tainer lid. Unscrew the clamp knob <strong>and</strong> pushdown to loosen, if necessary. Tilt the cap to the side to remove it fromthe tank.• Add sheath fluid to the sheath c<strong>on</strong>tainer (please use the blue bottle).• Replace the sheath c<strong>on</strong>tainer lid. Close the sheath lid <strong>and</strong> tighten theclamp knob to finger-tight.• Rec<strong>on</strong>nect the air line (green) <strong>and</strong> fluid line (Blue).Please pay attenti<strong>on</strong> to fluid line (Blue) to make sure it is not twisted orstretched.• Rec<strong>on</strong>nect Diva software with workstati<strong>on</strong> by click “Cytometer” >“C<strong>on</strong>nect”.• Remove air bubbles from the sheath filter.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!