<strong>DOE</strong>-<strong>STD</strong>-I090-<strong>96</strong> (Rev-I)2.1 CRITICAL-LIFT DETERMINATIONa An appointed person shall classify each liftinto one ofthe <strong>DOE</strong> categories (ordinary, critical,or preengineered production) prior to planning thelift.b. A lift shall be designated as a critical lift ifcollision, upset, or dropping could result in anyone ofthe following:1. Unacceptable risk ofpersonnel injuryor significant adverse health impact (onsite oroffsite).2. Significant release ofradioactive orother hazardous material or other undesirableconditions.3. Undetectable damage that wouldjeopardize future operations or the safety of afacility.4. Damage that would result inunacceptable delay to schedule or other significantprogram impact such as loss ofvital data.c. A lift should also be designated as critical ifthe load requires exceptional care in h<strong>and</strong>lingbecause ofsize, weight, close-toleranceinstallation, high susceptibility to damage, orother unusual factors.2-1Chapter 2Critical Lifts