30.07.2015 Views

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

triad® electronic ballasts - Conserve-A-Watt Lighting, Inc

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

T12High Output LampsT8 U-Shaped Lamps• 430 and 460 mA• 4´ Energy Saver LampApplications• Energy EfficientUNIVERSAL ®ELECTROMAGNETICBALLASTSFOR F40T12ES, F40T12/U, F40T12ES/U, F48“ 25W/UTLSAND WORKLITE 25 LAMPSFluorescent-ElectromagneticLamp Certification Line Input Ballast Min. F/CQty. Descr.LineVoltsCatalogNumber NOMCurrent Power Ballast(Amps)(<strong>Watt</strong>s) FactorEfficacyFactorCrestFactorTHD%StartTempSoundRatingWiringDiag. Dim.F40T12ES - High Power Factor1 Rapid 120 412-L-SLH-TC-P★• • • • • • .38 44 .88 2.00 < 1.9 < 20 60/15 A 42 D21 Rapid 277 458-L-SLH-TC-P★• • • • • • .17 44 .88 2.00 < 1.85 < 20 60/15 A 42 D22 Hybrid 120 420-L-TC-P◆ • • • • .50 59 .80 1.36 < 1.9 < 20 60/15 A 1 D22 Rapid 120 446-L-SLH-TC-P• • • • • • .65 74 .90 1.22 < 1.9 < 20 60/15 A 1 D22 Rapid 277 443-L-SLH-TC-P• • • • • • .28 74 .90 1.22 < 1.9 < 20 60/15 A 1 D22 Rapid 347 698-L-SLH-TC • • • .24 78 .90 1.15 < 1.9 < 20 60/15 A 1 D2F40T12ES - Normal Power Factor1 Rapid 120 413-C-TC-P❉ • • • .61 33 .68 2.06 < 1.9 < 20 60/15 A 8 D1F40T12 /U - High Power Factor2 Hybrid 120 420-L-TC-P◆ • • • • .64 74 .83 1.12 < 1.7 < 32 50/10 A 1 D22 Rapid 120 446-L-SLH-TC-P• • • • • • .76 90 .93 1.03 < 1.7 < 20 50/10 A 1 D22 Rapid 120 W-589-D-TC-P• • • .84 97 .92 0.95 < 1.7 < 20 0/-18 A 1 D42 Rapid 277 443-L-SLH-TC-P• • • • • • .34 92 .95 1.03 < 1.7 < 20 50/10 A 1 D22 Rapid 347 698-L-SLH-TC • • • .27 92 .93 1.01 < 1.7 < 20 50/10 A 1 D2F40T12ES/U - High Power Factor2 Rapid 120 446-L-SLH-TC-P• • • • • • .65 74 .90 1.22 < 1.9 < 20 60/15 A 1 D22 Rapid 277 443-L-SLH-TC-P• • • • • • .28 74 .90 1.22 < 1.9 < 20 60/15 A 1 D22 Rapid 347 698-L-SLH-TC • • • .24 78 .90 1.15 < 1.9 < 20 60/15 A 1 D2F48”25W/UTLS & WORKLITE - Normal Power Factor1 Rapid 120 413-C-TC-P❉ • • • .51 32 .90 2.79 < 1.7 < 20 50/10 A 8 D1❉ For Residential Use Only★ Not for use with “U” lamps◆ Not for use with Energy Saver “U” lamps• For Replacement OnlyOverall DimensionsMounting DimensionsDraw # L W H M XD1 6 7/16 1 7/8 1 1/2 6 -D2 9 1/2 2 3/8 1 1/2 8 57/64 111/16WIRING DIAGRAMSBlackLineWhiteYellow BALLASTYellowBlueBlueRedRedBlackWhiteBlueBALLASTRedRedHLAMPWDL MLAMPDiagram 1DIAGRAM 1LineUse disconnectlampholder onlyLAMPDiagram 8DIAGRAM LineBlackWhiteRedRedBALLASTBlueBlueLAMPDiagram 42DIAGRAM 42PAGE 1-12FOR MORE INFORMATION CALL1-800-BALLAST(225-5278)

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!