Fixed Pressurized W<strong>at</strong>er Spraying Syst. inMachinery Spaces• The number <strong>of</strong> sprinklers shall be so th<strong>at</strong> the w<strong>at</strong>er distribution in theprotected spaces is 5 liters/m2 minimum• The system can be divided in sections and the respective distributionvalves shall be oper<strong>at</strong>ed from outside the protected spaces• The system shall be always kept charged and the feeding pump will betriggered autom<strong>at</strong>ically in case <strong>of</strong> pressure drop• The pump shall be capable <strong>of</strong> supplyingw<strong>at</strong>er to all the sections simultaneously• The pump shall be loc<strong>at</strong>ed outside <strong>of</strong> theprotected spaces• The pump shall be driven by naindependent internal combustion engineM.Ventura <strong>SOLAS</strong> - Fire Protection 45Fire-Extinguishing Arrangements in ControlSt<strong>at</strong>ions, Accommod<strong>at</strong>ions and Service Spaces• Passenger ships w/ N > 36 shall be equipped with autom<strong>at</strong>ic sprinkler,fire detection and fire alarm systemM.Ventura <strong>SOLAS</strong> - Fire Protection 4623