Some Definitions (2)• Non-Combustible M<strong>at</strong>erials - m<strong>at</strong>erials th<strong>at</strong> do not burn or releaseflammable vapors up to 750° C, during the standard fire test.• Standard Fire Tests - tests carried out in a oven, in which parts <strong>of</strong>the relevant bulkheads or deck are raised to temper<strong>at</strong>urescorresponding to the standard time-temper<strong>at</strong>ure curve. The testedparts must:– Have an exposed area not less than 4.65 m2 and height (or length)not less than <strong>2.</strong>44 m.– Include a joint (where appropri<strong>at</strong>e)M.Ventura <strong>SOLAS</strong> - Fire Protection 13Some Definitions (3)• The standard time-temper<strong>at</strong>ure curve is a fair curve interpol<strong>at</strong>ingthe following points measured above the initial temper<strong>at</strong>ure <strong>of</strong> theoven:After5 min10 min15 min30 min60 minTemper<strong>at</strong>ure556º C659º C708º C823º C925º CM.Ventura <strong>SOLAS</strong> - Fire Protection 147