Chapter 6 — Class 8839 ALTIVAR <strong>56</strong> Combination DevicesBulletin No. 50006-519-01BControl Circuit Diagrams December 1996NOTES:CONTROL TRANSFORMER SHOWN FOR 460V PRIMARY.1 FOR 230V PRIMARY, JUMPER H2-H3 IS REMOVED ANDJUMPERS H1-H3 & H2-H4 ARE INSTALLED FOR 208VPRIMARY, REFER TO DETAIL AREMOTE STARTER BYPASS W/O OPTIONSPOWER CIRCUIT Z1415COMAO1AFC+10VAI1910MANUALSPEEDPOT2.5K2DELAY TIMER TR IS CONNECTED ACROSS COIL TERMINALSA1 & A2 ON IC CONTACTOR FOR ALL CONTACTORSEXCEPT THOSE WITH PART #S LC1FXXX. FOR THESE, TR ISCONNECTED IN SERIES WITH COIL TERMINAL A1.3AO2COMCOM11–2LO2AI2+13AUTO SPEED REF4 - 20 mADC SIGNAL3FUSES FU7 & FU8 SUPPLIED ONLY ON 50-100HP @ 460 VACOR 30-50HP @ 208/230 VAC.1LO1SSHLD12CONFIGURE CONTROLLER FUNCTIONS AS FOLLOWS:MENU 1 DAMPING = 100%MENU 6.1 TORQUE TYPE = VARIABLE OR VARIABLE LOW NOISEMENU 6.2 COMMAND TYPE 2-WIRE (MAINTAINED)4+24VLOPFAULTSIGNALR1BR1C28N.C. AFC29 FAULT CONTACT(CLOSES ON FAULT)MENU 7.12 LOW SPEED = 3 HZMENU 7.12 ACCELERATION = 10 SECMENU 7.12 DECELERATION = 10 SECMENU 7.13 CONTROL TYPE = NOLDOFFHAND AUTOX4IC<strong>56</strong>LI1LI2R1AR2BMENU 7.2 AUTO MANUAL = LI3AUTO RUN INPUT = LI4SPEED REFERENCE 2 = AI2MENU 7.3 R2 = RUNNING STATE32AFC MODE STATUS(CLOSES WHEN AUTOMODE IS SELECTED)X78AUTO START CONTACT(SUPPLIED BY OTHERS)LI3LI4RUNNINGSTATER2CR2A30N.O. AFCRUN CONTACT(CLOSES WHEN31 AFC RUNNING)33L1U/T1L2V/T2L3W/T3CL1GNDCL2FU3(5) IC (6)USERCONNECTIONSTBLI4 8+24 4USER SUPPLIEDAUTO START CONTACTFU2FU1(3) IC (4)(1) IC (2)LI2 6LI3 7+10 9AI1 10COM 11SHLD 12AI2 13COM 14AO1 15(ALTERNATE USER SUPPLIEDWIRING WHEN MODD07 IS USED)OFFHAND AUTOSPEED POT2.5 kAUTO SPEED REFERENCE–4 - 20 mADC SIGNAL+(INPUT Z=250)– PROGRAMMABLE ANALOG OUTPUT+ (REFER TO USERS MANUAL)FROMPOWERSUPPLYL1L2L3CB3 FU7FU8(1)TC(2)ISOLATION CONTACTOR (IC)(1)OLS1T1TC2223242526*FREEZE/FIRE STAT INTERLOCK(* REMOVE JUMPER IF USED)TRANSFER RUN CONTACT(CLOSES WHEN TC CONTACTOR IS CLOSED)FROMREMOTESTARTERS2S3(3)(5)TCTC(4)(6)(3)(5)OLOLT2T3TOMOTORR1R227282930313233FAULT CONTACT(CLOSES ON FAULT)RUN CONTACT(CLOSES WHEN AFC RUNS)AFC MODE STATUS(CLOSES WHEN AFC IS IN AUTO MODE)(USER SUPPLIED WITH D07 MOD)FU5(H1)(H3)460V(H2)FU6(H4)208 VAC1-25 hp VT1-25 hp VTLNTRANSFER CONTACTOR (TC)230 VAC1-40 hp VT1-30 hp VTLN50 hp VT40 hp VTLN460 VAC1-60 hp VT1-60 hp VTLN75-100 hp VT75 hp VTLNTRANSFORMER VA100 VA200 VA11T30-50 hp VT30-40 hp VTLN300 VA(X1)115V(X2)208V TRANSFORMER CONNECTIONFU4GND(H1)208V(H2)TC171T16(X2)GND115V(X1)AFCXOFFBYPASS 18 19TC34TR22 SECICOL35 22 23X2021IC36TSTCFREEZE/FIRESTAT INTERLOCKS(REMOVE JUMPERBETWEEN TERMINALS22 & 23 IF USED)REF: 52010-475-06Figure 96: Remote Starter Bypass Package “Power Circuit Z” “without Options1<strong>56</strong> © 1996 Square D All Rights Reservedηττπ://νιχοντρολσ.χοm

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!