Bulletin No. 50006-519-01BDecember 1996Chapter 2 — WiringEquipment RecommendationsTable 12: Maximum Allowable Line Fuse (F1 to F3) for 460 V Drive ControllersController ATV<strong>56</strong>•••N4 Class CC (Fast-Acting) Class T SemiconductorU41, U54, U72 600 V, 25 A 600 V, 35 A —U90, D12 — 600 V, 60 A —D16, D23 — 600 V, 100 A —D33, D46 — 600 V, 125 A —D54, D64, D79 — 600 V, 225 A —Table 13: Recommended Equipment for 1 to 50 hp 208/230 V Drive ControllersM1 A1 F1-F3 Input F1, F2 Control KM1 TS T1 F7, F8 F9MotorHPControllerATV<strong>56</strong>•••M2VTLowNoiseVT1 U41 U411.5 U41 U412 U41 U413 U41 U414 — U415 U72 U727.5 U90 U7210 D12 U9015 D16 D1220 D23 D2325 D33 D2330 D33 D3340 D46 D3350 — D46Line PowerFusesRatings,Fuse ClassCCFastActing600 V,10 A600 V,15 A600 V,20 A600 V,25 A600 V,25 AFuse CarriersControlFuses[2]FuseCarriersLineContactorTransientSuppressorXfmr[7]Primary XfmrFuses[2]T 208 V 230 V600 V,10 A600 V,15 A600 V,20 A600 V,25 A600 V,25 A600 V,35 A600 V,45 A600 V,60 A600 V,90 A600 V,110 A600 V,150 A600 V,150 A600 V,200 A600 V,250 A9080-FB3611CC [1] KTK-R-3T60030-3CR [2]9080-FB3611CC [1] KTK-R-3T60030-3CR [2]9080FB3611CC [1] KTK-R-3T60030-3CR [2]9080-FB3611CC [1] KTK-R-3T60030-3CR [2]9080-FB3611CC [1] KTK-R-3T60030-3CR [2]T60060-3C [2] KTK-R-3T60060-3C [2] KTK-R-3T60060-3C [2] KTK-R-33 ea.T60100-1C [2]3 ea.T60200-1C [2]3 ea.T60200-1C [2]3 ea.T60200-1C [2]3 ea.T60200-1C [2]3 ea.T60400-1C [2]KTK-R-3KTK-R-3KTK-R-3KTK-R-3KTK-R-3KTK-R-39080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CC9080-FB2611CCLC1-D2510G6LC1-D2510G6LC1-D2510G6LC1-D2510G6LC1-D2510G6LC1-D2510G6LC1-D2510G6LC1-D3210G6LC1-D4010G6LC1-D8011G6LC1-D8011G6LC1-D8011G6LC1-F115G6LC1-F115G6LA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA4-DA2GLA9-F980LA9-F9809070-K50D209070-K50D209070-K50D209070-K50D209070-K50D209070-K50D209070-K50D209070-K50D209070-K75D209070-K75D209070-K75D209070-K75D20FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1FNQ-R-1FNQ-R-1FNQ-R-19070- FNQ-R-K200D20 2-1/49070- FNQ-R-K200D20 2-1/4FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-3/4FNQ-R-3/4FNQ-R-3/4FNQ-R-3/4FNQ-R-1-6/10FNQ-R-1-6/10Sec.XfmrFuses[2]FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-1/2FNQ-R-6/10FNQ-R-6/10FNQ-R-6/10FNQ-R-6/10FNQ-R-1-6/10FNQ-R-1-6/10[1] Square D Class CC Fuse Block numbers.[2] Bussmann part numbers.[7] T1 has been dimensioned to supply KM1 coil inrush and sealed VA requirements only. Any user control / pilot device additions may require re-dimensioning of T1 VAcapacity.© 1996 Square D All Rights Reserved31ηττπ://νιχοντρολσ.χοm