<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersDear Friends,Once again we proudly present to you our new catalogue ofproducts.<strong>Public</strong> <strong>Address</strong> and <strong>Voice</strong> <strong>Alarm</strong> systems.This new impressive portfolio has been compiled in a whole newformat showing you our vision on product designs and productinnovation. As you go through the pages, you will discover thatour portfolio has undergone many changes compared to ourprevious edition. The new EN 54-16 standards are dominatingthe way products are presented and the sequence they areappearing in. This catalogue contains detailed information ona wide range of compliant <strong>Voice</strong> <strong>Alarm</strong> audio routers and signalprocessing devices, digital amplifiers, battery back-up units,paging consoles, IP-interfaces and communication units.System tutorials with detailed diagrams for products provide clearsystem design profiles. Additionally, you can find a comprehensiveselection of tools for system design (such as manuals, projecttutorials, AteÏs-studio designer software) on our website.Please take your time to study this collection of valuable informationand ensure yourself that AteÏs delivers the right products and thebest flexible solutions you have been looking for.Take the opportunity to share your thoughts with us and we willprovide you the solution!We are looking forward to your business!Team AteÏs isDel i v e r i n g Yo u r Me s s a g e !2 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersSYSTEM example # 1High rise buildings with distributed sound for multi-zone paging80 zones vertical cabling backboneThis tutorial describes a PAVA system, VACIE, which is usedfor voice evacuation with an automatic link to a fire-panelsystem, FACIE, for high rise building applications with multizonepaging requirements. The DIVA concept represents areliable and affordable system solution.The system consists of a central rack that contains allequipment including: DIVA8M Master unit and 9 pcs. ofDIVA8S Slave units, covering an 80 zones background musicand selective paging and voice evacuation system. Fromthe central rack, a multi-pair cable transports the audio tothe multiple zones with variable loads. The DIVA8M Masterunit provides the fireman’s operating section on the centralpaging facility rack and a touch-screen multi-zone pagingand control console. This part of the system is also linkedto the FACIE.8 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>The DIVA8M Master unit is linked with the DIVA8S Slave unitsusing a secured link over RJ45. Two powerful 1000 Wattamplifiers provide signals for paging and background music.The background music amplifier is also used as back-upamplifier in case of an amplifier failure. This unique conceptguarantees savings on rack assembly and amplifier power.The paging console is connected via a secured dedicatedlink with the central equipment racks.A TCP/IP link from the main system to the SERVICE area ismeant for maintenance use and remote access. The pagingdesk can do ‘all-call’ and zoned call announcements and hasa monitor loudspeaker in the unit for system monitoring.Central equipment rack:• 1x DIVA8M, for 8 zone paging• 9x DIVA8S, for 9 x 8 zone paging• 1x DPAsingle1000, Paging amplifier• 1x DPAsingle1000, Music & Backup amplifier• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 Paging console


DIVA8M systemSYSTEM example # 2ResortCentral equipment:• 1x Server PC with Vox-Net-Server,IP-media software• 1x IP call station, PMIP-D• 1x Intercom doorstation, UCIP-1• 2x Vox-Net-In, IP media licenceParking Area:• 1x DIVA8M, master unit• 1x DPAfour125, digital power amplifier• 1x BECS150, battery backup unit• 1x PSS-G2, paging console• 1x Vox-Net OUTPUT Node licenseRestaurants:• 1x DIVA8M, master unit• 1x DPAfour125, digital power amplifier• 1x BECS150, battery backup unit• 1x PSS-G2, paging console• 1x Vox-Net OUTPUT Node licenseWellness area:• 1x DIVA8M, master unit• 1x DPAfour250, digital power amplifier• 1x BECS150, battery backup unit• 1x PSS-G2, paging console• 1x Vox-Net OUTPUT Node licenseAccomodations:• 1x DIVA8M, master unit• 1x DIVA8S, Slave unit• 2x DPAfour250, digital power amplifier• 1x BECS150, battery backup unit• 3x PSM-V2, paging console• 1x Vox-Net OUTPUT Node licenseThis tutorial describes a PAVA system, VACIE, which isused for voice evacuation with an automatic link to a firepanelsystem, FACIE, for a resort with several buildings linkedover IP. The DIVA System concept stands for a reliable andaffordable system solution where each building has its ownFACIE linked to the VACIE consisting of a DIVA8M Master unitwith amplifiers and battery backup facilities.The system consists of 4 individual PAVA equipment setsthat are linked over IP. A server with special software,Vox-Net, surveys the audio/data connections between the 4 subsystems and the IP-paging facilities. Vox-Net - IP mediasoftware also provides surveyed intercom stations to beincluded into the system and provides multi-channels BGM.The standalone DIVA8M Master unit provides the fireman’soperating section on the central paging facility rack and atouch-screen multi-zone paging and control console. Thispart of the system is also linked to the FACIE.Depending on the situation, digital power amplifiers areused; 4 x 125 W, 4 x 250 Watt or 1 x 1000 W. DIVA8MMaster unit and DIVA8S Slave unit only need 2 amplifiers.One for Paging and one for BGM/Back-up. The backgroundmusic amplifier is also used as back-up amplifier in case ofan amplifier failure. This unique concept warrantees savingson rack assembly and amplifier power.The paging consoles, PSS-G2 and PSM8 are connected viaa secured dedicated link with the central equipment racks.When multiple PSM8’s are used into one DIVA8M Masterunit, only the first one, master, can be used for securitypurposes. The remaining ones, slaves, are not surveyed.A TCP/IP link from the main system to the SERVICE area ismeant for maintenance use and remote access. The pagingconsole can do all calls and zone-calls and has a feedbackloudspeaker in the unit for system monitoring.9


IDA4 systemIDA4M(s) and IDA4XM(s)Stackable PAVA system - MASTER & SLAVE UNITIDA4M / IDA4XM / Master unitIDA4Ms / IDA4XMs / Slave unitIDA4M /XM Product range responds to <strong>Public</strong><strong>Address</strong> requirements and EN 60849 compliance formedium and large scale installations. It comprisesthe cascading of an IDA4M Master unit and oneor several IDA4Ms/XMs Slave units. This moduleassembly extends the system’s capacity to 288inputs x 256 outputs.Each module unit houses: Audio digital signal processing(DSP), a matrix, a digital message player, amplifiersmonitoring with switchover to backup amplifier, andloudspeaker lines monitoring.Each module can support 1 PSSDT security microphoneconsole or up to 16 cascaded PSM8 microphone consolesand can process and route another four 0 dB audio inputsinto 4 different zones. Each channel is fitted with volumecontrols, equalizers, and a programmable delay. Each 0 dBinput feature contact and VOX activation (ideal when using thecordless microphone, for example). Up to 12 digital messagescan be downloaded and recorded as WAV files directlyfrom a computer into IDA4M/XM and IDA4Ms/XMs. Fourmessages can be played simultaneously in different zones.A security message is pre-programmed in 4 languages. Oneof the messages can be used as a chime for the PSS/PSM8microphone. 4 alarm inputs making it possible to obtain thepre programmed routings. The 4 output contacts can beused to disable the 100 V line attenuators.As an EN 60849 security system, all IDA4 Systemcomponents and peripherals are monitored. All incidentsare recorded into a data file which can be consulted on themaster module monitor display or on a PC. Also any detectedfaults are signalled by a general fault output contact. A localloudspeaker output enables selective listening to all thesources and the system’s 100 V output signals. The setupof IDA4 System is realised through a PC computer and theconfiguration software. (Windows compatible). Access canbe password protected. The routing and the level of themusic sources can be controlled directly from the PSS/PSM8microphones.Furthermore, IDA4M/XM and IDA4Ms/XMs can be combinedwith the IDA4SU when fault back microphone and a+b wiringfeatures are requested. Several IDA4 System racks can beremotely controlled from a remote location.A MODBUS protocol allows third party system to controlIDA4M/XM over a serial link.IDA4M(s) / XM(s) Features• From 5 to 280 audio inputs (0 dB balanced).• Up to 32 PSSDT security microphone consoleswith touchpad.• Monitoring of 4 to 256 100 V Loudspeaker zones.• Max 500 W per zone /amplifier.• Monitoring of 4 to 256 zone amplifiers,1 to 64 backup amplifiers.• Full monitoring of PSS microphone consoles(capsule, screen, touchpad, connections, LS).• Digital message players(12 messages,total length up to 2 min 11 sec.).• One message can be define as customized chime.• Digital audio bus between modules(32 channels, bandwidth: 20 kHz).• Digital signal processing (DSP).• Separate levels for the security sources.• Parametric equalization: 3 bands on inputs,7 bands on outputs.• Individual controls for each input and output level.• Separate levels for the security sources.• Free zone labelling.• 100 priority levels (contact or automatic detectionactivation).• Programmable delay of 0 to 683 msecs.• Measurements (levels and impedance) of amplifiersand LS lines.• Incident data record with up to 2048 incidents.• Possibility to store the event log file on a computer.• Internal clock.• IDA4XM and XMs have in addition to the abovespecifications Noise Sensing software for Ambient noisesensing on ONE input.11


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersIDA4SUStackable, Switching, PAVA unitIDA4SU / Microphone fault back and switching unitThe IDA4SU is an optional unit that will provide the IDA4M/XM and IDA4Ms/XMs range of units withthe following additional features:1) Fault back microphone : in case of failure of one or moreIDA4M/XM and their slaves units, the IDA4SU willautomatically connect one PSS microphone consoledirectly to all amplifiers inputs, allowing the user of thesystem to make an all call announcement.2) a+b zone wiring on same amplifier : when two speakercircuits are used in a zone, they can be connectedto the same amplifier. The IDA4SU Microphone faultback and switching unit will take care of the separateline surveillance according BS 5839-16 regulations.If one of the speaker circuit is shorted, then it will bedisconnected without influencing the other circuit of thecorresponding zone.The front panel LEDs will provide following information:1) Separate zone circuit status(Yellow if zone circuit is Faulty)2) Fault back microphone function(Yellow if bypass mode active)3) Power (Green if power supply is OK)The IDA4SU setup is supported by the SINAPS PCconfiguration software and does not require any additionalprogramming.IDA4SU Features• Microphone fault back.• a+b speaker circuits surveillance.• Separate LEDs for fault back and speaker circuitsstatus.• Surveillance of 8 speaker circuits (4 zones).• Setup integrated in Sinaps-M/XM softwares.• 230 VAC availability LED (green).• BS 5839-16 compliance.12 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


IDA4 system8 Zones <strong>Voice</strong> <strong>Alarm</strong> system with IDA4M and IDA4MsSYSTEM example # 3Central equipment rack #4• 1x IDA4M, for 4 zone paging• 1x IAD4Ms, for 4 zone paging• 1x DPAfour250, Paging amplifier• 1x DPAfour125, Backup amplifier• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 security paging console• 2x PSM8 paging console8 Zones <strong>Voice</strong> <strong>Alarm</strong> system with IDA4M, IDA4Ms and IDA4SUSYSTEM example # 4This tutorial describes a PAVA system, which is used for voiceevacuation with an automatic link to a fire panel system, forsmall to medium sized applications with simultaneous multizone paging requirements for up to 32 channels and amaximum of 256 zones.The IDA4 System concept still stands for a reliable and costeffective solution.The IDA4 System consists of a central rack that containsall equipment like: IDA4M Master unit and 1pcs. of IDA4sSlave unit, covering an 8 channel, 8 zone PAVA system withselective paging, <strong>Voice</strong> <strong>Alarm</strong> and selective backgroundmusic from multiple sources. From the central rack eachzone is separately wired to an individual amplifier.The PSS-G2 microphone console provides the fireman’soperating section from a central paging facility. This part ofthe system is also linked to the FACIE.The IDA4M Master unit and IDA4Ms Slave unit can beequipped with the IDA4SU. This way the system is madecompliant to the BS 5839 with A and B zoning.All zones are individually surveyed using 20 kHz impedancedetection. IDA4 Systems are equipped with a back-upamplifier and a no break emergency power supply. Thepowerful multichannel amplifiers DPA Series combine racksaving solutions with low current power consumption.This unique concept warrantees savings on rack assemblyand battery consumption.The paging console, PSS-G2, is connected via a secureddedicated link with the central equipment racks. For nonsecured call’s, a combination of PSM8’s microphoneconsoles are used.Central equipment rack #5, IDA4M and IDA4Ms withIDA4SU for A+B zoning according to BS 5839:• 1x IDA4M, for 4 zone paging• 1x IDA4SU, for A+B zoning (BS5839)• 1x IAD4Ms, for 4 zone paging• 1x IDA4SU, for A+B zoning (BS5839)• 1x DPAfour250, Paging amplifier• 1x DPAfour125, Backup amplifier• 1x PSS-G2 security paging console• 2x PSM8 paging console13


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersIDA8CNetworkable PAVA system - EN54-16 - Controller unitAteïs has more than 30 years of experience in the research and development of <strong>Public</strong> <strong>Address</strong> and <strong>Voice</strong> Evacuation systems. We now proudly introduce anew system that perfectly integrates Fire-<strong>Alarm</strong> with <strong>Voice</strong>-<strong>Alarm</strong> according to the EN 54-16 (VACIE&FACIE), BS 5839-part 8 and ISO 7240-16. ATEÏS hasdeveloped and will continue developing dedicated systems for <strong>Voice</strong>-<strong>Alarm</strong> applications.The IDA8 is a third generation modular systemthat complies with current architectural demandsrequiring IP-and/or Fiber-optics Networkingto cover for any complex design possible. IDA8responds to <strong>Public</strong> <strong>Address</strong> and <strong>Voice</strong> <strong>Alarm</strong>requirements as stated in EN 54-16, ISO 7240-16 and BS 5839/8, with specific attributes forcompliance in large installations.IDA8CThe IDA8C Controller unit houses: Audio digital signalprocessing (DSP), matrix control functions, digital messageplayer. Front panel access with; fully monitored firemanmicrophone, emergency message trigger button(s).Amplifier monitoring with hot-swap amplifiers, loudspeaker14 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>line impedance line monitoring. It can support up to fourPSSxx security microphone consoles with colour touch padand up to eight secured amplifiers plus two backup amplifiers,paging into 8 different zones per unit with A/B-line detectionaccording to the BS 5939-part 8. Two free card-slots areavailable for two optional 4 ch 0 dB audio in-or output cardsor two 4 ch AES/EBU cards.IDA8S Slave units can extent the system configuration withan additional 8 inputs and 8 outputs. The slave units areavailable with A/B speaker line configurations (IDA8SAB), orfor simple single speaker lines per zone (IDA8S).Each input and output channel is fitted with a wide range ofpre-and post-processing devices such as; volume controllers,routing mixers and switches, priority and paging components,equalizers, compressors, limiters, delay-lines, etc.Up to 4 hours of digital messages can be stored providinglive-recording or pre-recorded playback. External files canbe uploaded (WAV) from a computer into IDA8C. Up to 4messages in a single IDA8C Controller unit or a total of 48messages in an IDA8 system, can be played simultaneouslyinto different zones.IDA8C Controller unit enables operators to see a detailedoverview of the operational status of the entire PA systemwith a single push button. IDA8C Controller unit is able torun an impedance scan of all components connected to it,covering not only the input paging consoles but includingconnectors, cabling, processing blocks such as compressorsand limiters, delay lines and the network and loudspeakers.It stores a reference measurement of the system as it existsin a given configuration and environment. This reference issubsequently stored in the system. Any alterations to thisreference will be reported and are logged in an event log file.User definable thresholds can be applied to these references,allowing for customization to match circumstances.Being EN 54-16/ISO 7240-16 and BS 5839 part 8 securitysystems, all components and peripherals are monitored. Allincidents are recorded into a data file which can be consultedon the controller module monitor display or on a PC using theATEÏS Studio remote control software. Also, any detectedfault is signalled by a general fault output contact availableon the IDA8C Controller unit. A built-in loudspeaker outputenables selective listening to all the sources and system’s100 V output signals.IDA8C Controller unit is easily configured with our PC basedATEÏS-Studio global software (Windows compatible).Software access can be password protected. Onceprogrammed, the system will be able to work independently(off-line) without the need of a PC to be connected.IDA8C Controller unit characteristics• Interfaces: Standard Local Networking, 2 x RJ45. 100 m.• Ethernet interface, TCP/IP, MODBUS,Vox-Netand 3rd part devices.• 4 x Security microphone connection, RJ45, PC1 to PC4supports: MODBUS, Vox-Net and 3rd part devices.• 8 balanced audio inputs.• 8 balanced audio outputs + 2 audio outputsfor back-up amplifiers.• Return 100 Volt lines input from amplifiers.• Outgoing 16 (8+8) 100 Volt lines to the loudspeakers.(AB-zoning).• Optional 8 mic/line or AES/EBU audio inputs/outputs.• 9 logic inputs and 8 logic outputs.• Security contacts for: evacuation and faultreporting and fault-back inputs (BSI).• 4 hours of messages storage playing up to 48 messagessimultaneously in a IDA8 System.


IDA8 systemIDA8S and IDA8SABNetworkable PAVA system - EN54-16 - Slave unitThe IDA8S(AB) Slave units provide audio in- and output expansion of the IDA8 Systems using a secured 48-channel audio and data network over CAT5 or fiber optic. Each IDA8S(AB) expands the IDA8 System withan additional 8 audio inputs and outputs, 2 additional security microphone consoles (PSSG2) and securityprogrammable switching contacts.IDA8C and IDA8S(AB)are featuring:• 8 analogue audio inputs and 8 analogue audio outputs.The outputs have selectable 18 or 20 kHz monitoringsignal for end-off-line monitoring or, using definedmonitoring windows, individual monitoring with anaccuracy of up to 5% of the total line load.The Network cards that comes with the unit provides aredundant 48 channels audio and data connection, AteÏs-Net, between one controller and a maximum of 32 IDA8SSlave units in one rack system.Alternatively, if a greater distance between devices isrequired, the existing RJ45 redundant connection canbe exchanged for the optional Fibre optic NET-L3 cardsincreasing maximum distance up to 2 km between Controllerunit and Slave unit or between Slave units.The IDA8 Slave units come in two versions:1. IDA8SAB, this one has 8 audio outputs for A/B zoningaccording to the BS5839-part82. IDA8S, this one has 8 audio outputs for single zoning.IDA8SAB8 balanced 0 dB audio inputs and 8 balanced 0 dB audiooutputs, 2 security microphone access points, control inputsand outputs. Optional ATEÏS-Net Secured Audio Networkcards are available. BS 5839 compliant with A/B zoning.IDA8S8 balanced 0 dB audio inputs & 8 balanced 0 dB audiooutputs, 2 security microphone access points, control inputsand outputs. Optional ATEÏS-Net Secured Audio Networkcards are available.• 8 alarm control inputs and 8 output relays are freelyprogrammable for system actions and priorities can beassigned to these inputs.• 2 card slots for optional 8 microphone/ line or AES/EBU audio input/output channels. These inputs/outputsare free software configurable.• Compatibility with the TERRACOM IP-media streamersallowing for additional IP-Audio IN/EXstreamer units,IP-media consoles and IP-Paging consoles.• The ATEÏS Net Secured Audio Network that is providinga Single or Multi-mode, 48 audio channels, 32bit,48kHz, redundant network.• Up to 256 priorities that can be configured for up to256 zones (512 AB) in the LOCAL Network.• A system configuration that can connect up to 32 IDA8Cwith IDA8S(AB)’s over the LOCAL Network allowing asystem configuration of up to 32 x 8 zones.• Independent operation without a PC connected to it.The PC can be disconnected after configuring the system.• Front panel colour touch-screen display andcorresponding push buttons, that allows for simplenavigation through the various system menu’s.• Automatic messaging in the IDA8C Controller unit andIDA8S(AB) Slave units with a capacity of up to 4 hoursof WAV format audio files. The audio messages can beuploaded via Ethernet link.• 4 audio streams that can be activated at the same timeand up to 48 in the IDA8 System.• Message player and messages monitoring.• Full monitoring starting at the capsule of a microphoneconsole to the end of a loudspeaker line. The externalcables connected to the control inputs are monitoredfor short and open circuit and earth leakage.• Standard test, alarm and chime-tones are stored inthe IDA8C Controller unit and IDA8S(AB) Slave units.• An internal real time clock for automatic scheduledactivities like; playback of messages, automaticvolume changes during day and night or backgroundmusic settings.• Extensive audio pre and post processing possibilities foraudio inputs and audio outputs.• A monitoring loudspeaker and fireman’s microphoneon the IDA8C Controller unit.• Cost effective solutions using switching modefor multi-zoned amplifier usage.• Full system redundancy using the IDA8RU redundantswitching devices.15


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersIDA8C Controller and IDA8SAB Slave unitDual channel switchingAs with the DIVA8 System concept, that is focused on low-entry market solutions, IDA8 System also provides cost effective solutions where only paging or paging with BGM isrequired. This solution is based on switched audio distribution from a single amplifier into a large number of groups. Besides the switching solution, IDA8 System can createcombinations where single-zoned amplifiers are combined with multi-zoned amplifiers.Adjacent diagram shows the Multichannel & Dual channel solutionwhere IDA8 System is linking asingle zoned amplifier section with amulti zoned amplifier section.Multi channel & Dual channel solutionDual channel only solutionThe 2 amplifiers that are used in the multi-zonedamplifier section are serving zone 17 up 32 havingonly 2 amplifiers per IDA8SAB Slave unit. Oneamplifier is used for the PAGING/ALERT signals,the other one for the BGM and the BACK-UPfunction.The BGM/BACK-UP amplifier must have the samesize as the PAGING/ALERT amplifier for amplifierback-up in case of an amplifier failure.This solution requires only 2 amplifiers perIDA8SAB Slave unit. The remaining part of thissolution is using one amplifier per zone.Adjacent diagram is also showing aDual channel only solution. IDA8CController unit is linking multi zonedamplifiers over multiple IDA8 Slaveunits.The 2 amplifiers that are used in the multi-zonedamplifier section are serving zone 9 up to 24having 2 amplifiers only. One amplifier is used forthe PAGING/ALERT signals, the other one for theBGM and the BACK-UP function.Because of the requested load in this example, thechannels 1 to 8 have their own two multi-zonedamplifiers.The BGM/BACK-UP amplifier must have the samesize as the PAGING/ALERT amplifier for back-up incase of amplifier failure.16 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


IDA8 systemNET-LxATEÏS Net Secured Audio Network - EN54-16 - Networking CardThe IDA8 System is made for medium to large sized installations, such as shopping malls, retail stores,trainstations, airports, etc. The IDA8 System has an open design architecture and interfaces with remotedevices such as paging consoles, audio break-in and break-out convertors and room-controllers. ATEÏShas developed its own audio networking system ‘’ATEÏS-Net’’The systems architecture is based on two redundant ‘daisychain’methodes. A so called Local Network and a so calledGlobal Network.- The LOCAL Network (NET-Lx) daisy-chains up to 31IDA8S(AB) Slave units with one IDA8C Controller unit, creatinga true audio matrix of 256 x 256 over a full redundant LocalNetwork.- The GLOBAL Network daisy-chains up to 32 ControllersIDA8C Controller units over a GIGA bit open network.This GLOBAL Network is used to create a redudant linkbetween multiple decentralised IDA8 systems. The size ofsuch a system can reach up to a multiple of 256 x 256inputs and outputs.For interfacing between Controllers, Controller and Slaves,AteÏs has developed a dedicated audio and data hardwareapplication, AteÏs-Net, with proprietary low latency protocol.AteÏs-Net cards are available for copper (RJ45) andfiber-optic, creating dedicated network distances of up to20 kilometers, using single mode fibre-optic transducers.Further interfacing are included using TCP/IP for third partyinterfacing with PC based remote controller, Terracom IPmediastreamers and TCP/IP paging and operating consoles.Serial RS485 and RS232 connections supporting Modbus,Vox-Net and thrid party protocols are available on the units.ATEÏS-Net Secured Audio NetworkThis Ethernet based network is able to simultaneouslytransport 48 audio channels (32 bits, 48 kHz sampling rate)with a latency < 1 msec together with the necessary controldata over a CAT5 or Fiber optic dedicated network.For the LOCAL and GLOBAL system networking, optionalATEÏS-Net networking cards can be added inside the IDA8CController unit and IDA8S(AB) Slave unit.NET-L1Dedicated LOCAL / GLOBAL ethernet networking card with2 x RJ45.NET-L3Optional dedicated LOCAL / GLOBAL ethernet networkingcard with 2 x fiber.Thanks to its loop architecture, the ATEÏS-Net audio networkis fully redundant. If a problem (line open or shorted) occurson a loop segment, it will be automatically isolated withoutaffecting the system functionalities.Up to 32 IDA8C Controller units and/or IDA8S(AB) Slave unitscan be connected together onto the same LOCAL or GLOBALnetwork. As the Network addresses are auto negotiated, thenetwork set up is very easy. Once programmed the systemwill be able to work independently (off-line) without the PC.IDA8C Controller units and/or IDA8S(AB) Slave units can beequipped with with NET cards, RJ45 to RJ45, with a standardinstallation distance of 100 m between Controller and Slaveand/or Slave and Slave. Or for bigger installation distances,optional IDA Net-2-3 and 4 can be used to extend distancefor up to 2 km between units in multi-mode or 20 km insingle-mode.NET-L2Optional dedicated LOCAL / GLOBAL ethernet networkingcard with 1x fiber (port A) + 1 x RJ45 (port B).NET-L4Optional dedicated LOCAL / GLOBAL ethernet networkingcard with 1 x RJ45 (port A) +1 x fiber (port B).Port A = IN,Port B = OUT17


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakerssystem example # 5Multiple office buildingsEquipment building 1:• 1x IDA8C for 4 zone paging• 1x NET-G3, Fiber-optic card (Global Network)• 1x DPAfour125, 4 zones• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 Paging consoleEquipment building 2:• 1x IDA8C for 8 zone paging• 1x NET-G3, Fiber-optic card (Global Network)• 2x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 paging consoleThis example describes a PAVA system, VACIE,that is used for voice evacuation with an automaticlink with a fire panel system, FACIE.The system is split into 3 rack systems, for each building.Each building has the facility for local and global paging.General calls and service calls are been delegated from thegate houses.The overall connection between the buildings is based ona redundant fiber-optic core that carries up to 48 audiochannels. The paging consoles are connected via a secureddedicated link with the central equipment racks.Equipment building 3:• 1x IDA8C for 8 zone paging• 1x NET-G3, Fiber-RJ45 card (Global Network)• 1x NET-L1, RJ45 – RJ45 (Local Network)• 2x DPAfour125, 8 zones• 1x IDA8S for 8 zone paging• 1x NET-L1, RJ45 – RJ45 (Local Network)• 2x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up device• 4x PSS-G2 paging consoleEquipment gate-house:• 1x TCP/IP switch• 1x IP-PSS paging console• 1x PC-consoleA TCP/IP link from the main system to the gatehouseestablish the communication link with the gatehouse pagingdesk. This paging desk can do all-calls and zone specificcalls and it has a monitor loudspeaker in the unit. The PC isfor maintenance use.18 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


IDA8 systemsystem example # 6High-rise buildings with distributed soundEquipment rack Basement:• 1x IDA8C for 8 zone paging• 1x NET-L1, RJ45 – RJ45 (Local Network)• 2x DPAfour250, 8 zones• 1x IDA8S for 8 zone paging• 1x NET-L2, Fiber - RJ45 (Local Network)• 2x DPAfour250, 8 zones• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 Paging consoleEquipment rack 11th to 20th floor:• 1x IDA8S for 8 zone paging• 1x NET-L1, RJ45 – RJ45 (Local Network)• 1x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up device• 1x PSS-G2E Paging consoleThis example describes a PAVA system, VACIE, that is usedfor voice evacuation with an automatic link with a fire-panelsystem, FACIE, for high-rise building applications.The system contains a central rack that is based in thebasement of the building and is covering for the first floors,central paging facilities and maintenance PC. This part of thesystem is also linked to the FACIE.Since high-rise buildings suffer from power-loss in cablesdue to the long cable lengths, IDA8S Slave unit withamplifiers are positioned decentralized and evenly dividedbetween floors. This ensures the shortest routes betweenamplifiers and speakers. To connect the IDA8S Slave unitswith the IDA8C Controller unit a combination of NET cardsare used.From the IDA8C Controller unit to the first Slave unit Fiberto RJ45, from the first IDA8S Slave unit, to the second andfollowing, NET-L4 RJ45 to RJ45 and the last IDA8S Slaveunit will have NET-L4 RJ45 to Fiber.The overall connection between the floors is based on aredundant IDA8 System Network that carries up to 48-audiochannels. The paging consoles are connected via a secureddedicated link with the central equipment racks.A TCP/IP link from the main system to the SERVICE area ismeant for maintenance use and remote access. The pagingconsole can do all calls and zone specific calls and has afeedback loudspeaker in the unit for system monitoring.Equipment rack 21th to 30th floor:• 1x IDA8S for 8 zone paging• 1x NET-L1, RJ45 – RJ45 (Local Network)• 1x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up deviceEquipment rack 31th to 40th floor:• 1x IDA8S for 8 zone paging• 1x NET-L1, RJ45 – RJ45 (Local Network)• 1x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up deviceEquipment rack 41th to 50th floor:• 1x IDA8S for 8 zone paging• 1x NET-L2, Fiber - RJ45 (Local Network)• 1x DPAfour125, 8 zones• 1x BECS150, Power & Battery back-up device19


IDA8 systemsystem example # 7Railway information PAVA systemThis example describes a PAVA system, VACIE, that is usedfor voice evacuation with an automatic link with LOCAL firepanelsystem, FACIE, for a railway application or any systemwhere security needs to be combined with multiple remotelypositioned standalone PA facilities over IP.In the contrary to the examples 6, 7 and 8, this system doesnot contain a central equipment rack. The whole setup isbased on multiple standalone and self-supporting PA-VAsystems that are linked over a dedicated TCP/IP-Network.Each system has a link to the local FACIE and contains asecured paging facility with power back-up. From otherremote positions, general and selective calls can be madeor automated messages can be played simultaneous overthe TCP/IP-Network using Vox-Net multi-point IP-mediasoftware that runs on a redundant PC with a back-up locationelsewhere on the network.The system also contains multiple non-secured PSS-G2ETCP/IP microphone console at various locations such asticket locations or supervisor offices. It also provides VNB IPmediastreamers used as break-out boxes for paging only inthe train maintenance area along the track.A remotely positioned PC with a redundant message-playerprovides services and automated messages.Decentralized Equipment rack 1 and 3 (typical):• 1x IDA8C for 8 zone paging• 2x DPAfour250, 8 zones• 1x BECS150, Power & Battery back-up device• 1x PSS-G2 Paging consoleRemote paging consoles:• 1x PSS-G2E Paging consoleRemote paging locations:• 1x VNB2,4-1, TCP/IP 2 audio in and 2 audio outmediastreamer.• 1x DPAfour250, 4 zones21


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIDA8 systemIntelligent Acoustic SolutionsLoudspeakersIDA8RU-SL/CT/PCIDA8 Redudancy Switching UnitIDA8RU-MAIN / Redundant security Matrix switcherIDA8RU-PDC / Redundant Ancillary audio switcherIDA8RU-CTL / Redundant Contact switcherPAVA systems in very highly sensitive places like nuclearpower centrals, underground industrial systems or placeswhere people have to thrust on a 100% availability of aPAVA system, may require for redundancy on any part ofthe PAVA system. Redundancy is a very widely-spreadexpression that needs to be further specified into a requiredlevel of redundancy. In normal PAVA systems where othercommunication means are available, spare amplifiers andsurveillance of essential components is more than enough.Higher levels of redundancy may require for A/B wiring of theloudspeaker lines where loss of the A or B line or system stillensures a minimum coverage of 50% of the venue. (Suchrequirement is detailed described in the BSI-5839 -part 8).But even that could not be enough in situations where thePAVA is the only and last means of communication. In thiscase an even higher level of redundancy may be required. Atthis level, not only the amplifiers have redundancy by meansof active spare amplifiers, also the central equipment willhave a full back-up.This is what we call: Full-Redundancy.AteÏs ID8RU provides this high level of redundancy. ID8RUis a thorough switching device that acts as a Primary /Secundary switching device for:- Digital audio and processing matrix IDA8C, pagingconsoles and interfaces: IDA8RU-MAIN.- Security and normal contacts IN and OUT: IDA8RU-CTL.- Auxiliary audio IN and OUT, two additional pagingconsoles and telephone line: IDA8RU-PDC.The IDA-RU’s can create redundancy for IDA8C Controllerunit and for the IDA8SAB Slave unit.(More detailed information can be found in the: IDA8RU-Redundancy switching unit datasheet).IDA8RU-MAIN / CTL / PDC• Case: 19” 2U (IDA8RU-MAIN), 1U (IDA8RU-CTL / PDC).• Power supply: 2 x 24 Vdc redundant inputs.• Redundancy:IDA8RU-MAIN: 8 speaker lines, 8 amplifiers, 2 backupamps, 2 PSS inputs.IDA8RU-CTL: 8 x Output contacts, 9 x alarm inputs.IDA8RU-PDC: 8 x 0dB inputs or outputs , 2 PSS inputs,2 Tel inputs.• Switching: Electro mechanical relays.• Switching time: 6 seconds (IDA8 watchdog period).• Connections: RJ 45, Screw terminals blocks.• LED display: power, Primary IDA8 system active,Secundary IDA8 system Active.• Control inputs: Primary IDA8 system watchdog,Secundary IDA8 system watchdog.22 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>• Control outputs: Primary IDA8 system active,Secundary IDA8 system Active, Expansion.


Consoles & accessoriesPSS-G2 / CD16 / PSM8 with DIVA8 SystemPSS-G2 / PSM8 / CD16 with IDA4 SystemPSS-G2 / PSM8 / CD16 with IDA8 SystemPSSG2E with DIVA8 and IDA8 SystemCOMPATIBILITY DIVA8 System IDA4 System IDA8 SystemCD16 V 1 pcs Secured onMaster unit. 2 nd andmore on Master unitare not securedV 1 pcs Secured onMaster or Slave unit.2 nd and more on Masteror Slave unit are notsecuredMax. 32 in a systemand 10 in Master-slavestringMax. 32 in a systemand 10 in Master-slavestringPSS849 X V 1 pcs per IDA4xx XMax. 1 in a systemPABFMP X V 1 pcs per IDA4xx Master Xor Slave unit, using oneaudio inputPSS96DT X V 1 pcs per IDA4xx Master Xand/or Slave unitPSSG2-16 V1 pcs on Master unit(g2)Max. 1 unit in a systemPSSG2 V 1 pcs on Master unit(g2)Max. 1 unit in a systemPSSG2E V Max. 8 pcs over TCP/IP (g2)PSM8 V 1 pcs Secured onMaster unit. 2 nd andmore on Master unitare not secured. Using1x audio inputMax. 32 in a systemand 10 in Master-slavestringSHM-1 V 1 pcs supplied with theDIVA8 SystemVMax. 32 in a system1 pcs per IDA4xx Masterand/or Slave unitMax. 32 in a systemV 1 pcs Secured onController or Slaveunit. 2 nd and more onController or Slave unitare not securedVMax. 32 in a systemand 10 in Master-slavestring4 pcs per IDA8C unit &2 pcs per IDA8S unitMax. 64 in a systemX V Max. 8 pcs over TCP/IPX 1 pcs Secured onMaster and/or Slaveunit. 2 nd and more onMaster and/or Slaveunit are not secured.Using 1x audio inputMax. 32 in a systemand 10 in Master-slavestringV In combination withIDA-SEC, using oneaudio inputSPM-1 X V In combination withIDA-SEC, using oneaudio inputNSM X V 1 pcs on Master and/orSlave unit.EVACg2-x V 1 pcs on Master unit V 1 pcs per IDA4xx Master(g2)and/or Slave unitDIGIM1 V Using one audio inputwith DIGI-INTDIGIM4 V Using one audio inputwith DIGI-INTDIGIM8 V Using one audio inputwith DIGI-INTPM1 V Using one audio input +one contactVVVUsing one audio inputwith DIGI-INTUsing one audio inputwith DIGI-INTUsing one audio inputwith DIGI-INTV Using one audio input +one contactV 1 pcs Secured onController and/or Slaveunit. 2 nd and more onController and/or Slaveunit are not secured.Using 1x audio inputMax. 32 in a systemand 10 in Master-slavestringV In combination withIDA-SEC, using oneaudio inputV In combination withIDA-SEC, using oneaudio inputVVVVV8 pcs on Controller and/or Slave unit.4 pcs per IDA8C unit &2 pcs per IDA8S unitUsing one audio inputwith DIGI-INTUsing one audio inputwith DIGI-INTUsing one audio inputwith DIGI-INTV Using one audio input +one contactPPMIT5 X X V Ethernet multi-targetunit. One audio inputURC X X V Using RS485URC-200 X X V Using Ethernet23


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersCD 16 / PSMAll SECURED paging devicesCD16- Wall mounted cabinet remote paging consolefor IDA8/DIVA8Wall-mount heavy duty remote paging console with Accesslevel 2 protection to comply with the EN 54-16. Compatiblewith DIVA8 System, IDA4 System and IDA8 System andcommunicates over a dedicated RS485 for Power, audioand DATA.The unit comprises of 16 zones / 16 buttons with fistfiremen’s microphone in a metal surface mount wall-box.It provides robust IP-30 protection. Each CD16 contains aPSM Master PCB with extension keypad and uses the samearchitecture as for the PSM series of microphone consoles.Each DIVA8 System, IDA4 System and IDA8 System canhandle up to 32 CD16 units with a maximum of 10 on oneline in Master/Slave configuration. (Note that only the Masterunit is secured, Slaves are not).The buttons can represent a single zone or a group of zones.All buttons can be programmed with drag & drop featuresfrom the DIVA8 System, IDA4 System and IDA8 System GUIand the PTT button can be programmed for Push To Talk orfor latching functionality.The unit offers “Hold” and “Busy” LED signals in addition tothe zone LED’s, and these allow the easy identification ofselection / Busy signals for the user. In addition, to complywith EN 54-16, separate POWER, FAULT and EVAC indicatorsare provided.Additional RCA connectors with selection buttons supportlocal audio injection for commercial usage.The RS485 communication protocol offers daisy chaining ofup to 300 m on a simple CAT5 cable, and yet makes outletseasy to connect via a standard RJ45 connector.cd16 characteristics• 16 buttons / Music button 1&2 plus separatePTT button.• Firemens fistmicrophone with PTT (CB-type).• Distortion less than 0.6%.• Inputs S/N ratio: >75 dBu.• Frequency respond: 100 Hz - 16 kHz(For the electronics).• Feedback speaker.• 2 stereo RCA entries with selection buttons.• 3 LED indicators: Power/GeneralFault/Evacuation active.• Voltage: 24 VDC (Provided by DIVA8 System,IDA4 System and IDA8 System).• Dimensions: 334x247x134 mm.• Colour: RAL 7016.PSMxx:Unidirectional Condenser <strong>Address</strong>able Microphone,compatible with all system units, PSMxx uses an RS485protocol over a single CAT5 cable connection, to transportboth Audio and Power from the PSMxx to the systemunits. The PSMxx comprises of 8 zones / 8 buttons withsleek condenser gooseneck microphone, and spring metalprotection, providing durability and excellent aesthetics aswell as allowing up to 256 zones expansion via the additionalKeypad easy extension station. The buttons can represent asingle zone or a group of zones and are easily defined via theGUI of the system units using a simple Matrix selection.The unit offers “Hold” and “Busy” LED signals in addition tothe zone LED’s, and these allow the easy identification ofselection / Busy signals for the user.All buttons can be programmed with drag & drop featuresfrom the System unit GUI software and each button canbe programmed for Push To Talk or Latch functionality.Theunidirectional condenser microphone warrants high qualityJunction boxdirective signal pick up from the user and hence lessinterference from the surroundings thanks to the cardiodpolar pick-up pattern.The RS485 communication protocol offers daisy chaining ofup to 100 m on a CAT5 cable, and yet makes outlets easy toconnect via a standard RJ45 connectors. (The microphonecompatibility listing shows the maximum number of units perSystem).Main Features: - 8 paging programmable keys with statusand 1 All call buttonPPM Keypad / additional Keypad forPPMxx.PPMxx characteristics• Base dimensions (HxWxD): 200 x 107 x 345 mm• Weight: Approx.0.55 kg• Colour: Ral 7035• Gooze-neck length with mic.: 300 mm• Cable length: 900 m• Comes standard with Junctionbox (JB)and CAT5 cable (1.5 m).24 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


Consoles & accessoriesPSS-G2 / PSS-G2/16 / PSS-G2E / PSS849 / PSS96DTAll SECURED paging devicesPSS-G2-XX Generic informationThese call stations can have either a dedicatedand secured audio and communicationlink or a non-secured but flexible TCP/IPcommunication link.The PSS-G2 paging console is a man-machine interfacewhich allows call-paging, messages broadcasting and DSPmatrix parameter control. The PSS-G2 units connect to asecured bus. Its back-lit touch screen is designed for simpleand user-friendly operating. The 3-hardware-keys can befreely assigned within the System control software. Variousoperating levels with password protection make the PSS-G2a versatile device that fits well in a commercial shoppingcenter as for an industrial high security environment.All paging parameters needed for site operating can beprogrammed: zones assigned to the different buttons,name of zones, group of zones, messages triggering, levelsadjustments and pre-call chime but also for fader control,button control or event control.The message and the chime are stored into the PSS-G2.A total of 168 keys over 12 pages allow zone or group ofzones selections. Each key contains a green colour changingfield indicating that the zone is occupied by a differentprocess.The PSS-G2 comes in three versions:• PSS-G2, 168 zones securitypaging station with dedicatedMODBUS link for DIVA8 System,IDA4 System and IDA8 System.• PSS-G2/16, 16 zones securitypaging console for DIVA8 System.• PSS-G2E, 168 zones NON-Securitypaging console with ETHERNET linkfor remote paging over TCP/IP forDIVA8 System and IDA8 System.PSs-g2 characteristics• 5” TFT full colour touch-screen• 3 LED indicators: Power/General Fault/Evacuationactive• 3 key-buttons: User definable using Ateis Studio GUI• 168 Touch fields: 14 pages with 12 keys ,for PSS-G2 & PSS-G2E• 16 Touch fields for PSS-G2/16• Console size: (L x W x D) 250 x 140 x 80 mm• Microphone flex length: 280 mm• Weight: 1098 g - Colour: RAL 7016• Front tilted at 30°• Material: metal back, PVC top and sidesPSS849, PSS96DT Console device /Monochrome touch screen security paging console for IDA4 (X)M(s):The PSS849 and PSS96DT paging microphone consoles area man-machine interface which groups together all functionsrequired by the EN 60849 and BS 5839 part 8 regulations.Its back-lit touchpad is made for simple and user-friendlyoperating.It can be configured either using a PC computer, or by usingcontrol keys of the front LCD screen of the IDA4 System unitto which it is connected. Access can be password-protected.All parameters needed for site operating can be programmedlike; zones assigned to the different buttons, name of zones,zone groups, priorities, access to different messages, levelsadjustments, pre-call chime, press-to-talk, music ON/OFF and music routing. Its large Monochroom-LCD screenprovides an overall view of busy zones and active sources. A‘on-screen’ VU meter controls the microphone presence andmodulation level. A built-in loudspeaker makes it possible tolisten to all system-generated messages and announcements.The PSS849 and PSS96DT are fully monitored (microphonecapsule, powersupply, touchscreen, audio and RS485connections). Any system faults are detected, located andindicated clearly on the screen.Different product references areavailable to suit all site sizes:• PSS849: 12 zones forIDA4 and IDA4XM• PSS24DT: 24 zones forIDA4M/XM• PSS96DT: 96 zones forIDA4M/XMPSS849, PSS96DT characteristics• High-quality electret omnidirectional microphone..• Back-lit touch pad (no push buttons).• Programmed by PC using IDA4 System software.• 1 PSSDT per IDA module.• Up to 32 PSSDT per IDA4(X)M(s) system.• Group calls and All calls functions.• Pre-call chime (pre-recorded as one of theIDA4M or IDA4XM messages).• Press-to-talk or ON/OFF buttons.• Music ON/OFF IDA4(X)M(s) System.• Music routing (IDA4(X)M(s) System• Display of all system incidents.• Buzzer which signals faults.• Remote control for digital messages with zone• LED system status display (evac, fault and power).25


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersConsoles& accessoriesPSS / DIGIM / PM1 ....Paging StationsPSSKB / 2 buttons keyboard for PSSmicrophonesSPM1 / Security handheld microphoneSHM1 / Security handheld microphonePM1 / Paging microphoneKBAdditional module to be fixed at the side of the PSSmicrophone. Several PSSKB can be mounted on the samePSS microphone. The buttons can be assigned to thefollowing functions :Single zone microphone console. The EN54-16 surveillanceFiremen microphone for All call, group or zone calls. TheSingle zone pre-amplified paging microphone.1) Fault back Microphone triggering2) Messages triggeringis realized thanks to the IDASEC interface.EN 54-16 surveillance is realized thanks to the IDASECinterface.IDA INT / Connexion boxPABFMP / Sensing microphoneIDA SEC / InterfaceDIGIM1 / DIGIM4 / DIGIM81 / 4 / 8 zone microphoneThe PABFMP houses a heavy duty sensing microphoneand a specially designed preamplifier. The 0 dB audiosignal is send to one IDA4XM input allowing the system toautomatically control the amplification (AGC) depending onthe ambiant noise.The IDASEC secures and survey the SHM1 and SPM1evacuation microphones to comply to the standardEN 54-16.• Electret cardioid capsle • Integrated preamplifierwith level adjustment • Output level max: + 6 dBbalanced • Impressive array of signal processingtools • Easy to use PC software for system design andcontrol (GUI) • Advanced Preset manager • Powerfulmicrophone paging and remote control functions • Highlyflexible input and output configurations.EVAC-BOARD / <strong>Alarm</strong> input boardPS24 / Power supply and audio monitoring unitDIGIINT / Interface to connect the DIGIMNSM / Sensing microphonemicrophoneThe PS24 is an optional unit that will provide the IDA4systems with the following additional features :1 - 24 VDC power supply : the PS24 is a 230 VAC to 24 VDCpower converter able to deliver up to 4.5 A at 24 VDC. Thus,up to 6 IDAs and 6 PSS or 12 IDAs can be powered from theThe EVAC BOARD is an extension unit to the IDA4M/XMand IDA8-Systems. Each EVAC BOARD will provide thosesystems with 32 additionnal alarm inputs. Each input ismonitored and can be programmed to trigger a digitalaudio message into a specific zone or group of zones. TheEVAC BOARD is linked to the System units trough a RS232/RS485 monitored serial link.PS24. The six 24 VDC output connectors together with thebattery backup input allow for easy and clean rack wiring.2 - The 8 Ω - 1 W loudspeaker mounted on the PS24 frontpanel can be connected directly to the IDA4’s modules forin rack audio sources or zones monitoring. Those featureswill greatly facilitate the wiring and rack mounting of theIDA4 range.• Electret cardioid capsle • Integrated preamplifierwith level adjustment • Output level max: + 6 dBbalanced • Impressive array of signal processingtools • Easy to use PC software for system design andcontrol (GUI) • Advanced Preset manager • Powerfulmicrophone paging and remote control functions • Highlyflexible input and output configurations.The NSM assures the omnidirectional soundrecording and preamplification of the surroundingbackground noise.The 0 dB modulation is sent through the IDA8 in orderto provide the automatic gain control feature of theA.N.G (Auto Noise Gain) component and allows thelevel adjustment where the NSM is implemented.26 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


Amplifiers & AccessoriesDPA / BECSD-Class Power Amplifiers, 19”- EN54-16DPA four characteristics• DPA four 125: 4 x 125 Watt class-D power amplifier.Can be bridged into 2 x 250 W.• DPA four 250: 4 x 250 Watt class-D power amplifier.Can be bridged into 2 x 500 W.• DPA single 1000: 1 x 1000 Watt class-Dpower amplifier.• 2U high, 19-inch rack mountable.• Quiescent current in sleep mode: 30 mA.Security Amplifiers, EN 54-16The DPAfour is a 2U high 19” rack mountable,4-channel class-D power amplifier, transformer isolatedfor 100 V, 70 V, 50 V and low-impedance distributedloudspeaker systems. Each amplifier can deliver up to1000 Watt when used in bridged mode or in separatechannels of 125 or 250 Watt.DPAfour1254 x 125 Watt class-D power amplifierThis amplifier has a dual voltage mains 110/230 VACand a 24 VDC battery back-up input which allows it tobe used in combination with a battery backup systemfor maximum availability and durability in an emergencyevacuation system. There are 3 types of power amplifiersavailable in the DPA four range of products.DPAfour2504 x 250 Watt class-D power amplifier• Front panel indicators include:General status: Power, Battery, Service and GeneralFault. Detailed status: Signal, Clip , Fault andReady (Ready = out of sleep mode).• 100 / 70 / 50 / 4 Ohm available via terminal blocksat the rear.• Output channels can be linked into 2 x 250 Wor 2 x 500 W by daisy-chaining 50 V tapping (inputon parallel).• Combines with the BECS150 chargerand back-up supply.DPAsingle10001 x 1000 Watt class-D power amplifierCharger and monitoring unit for DPA-amplifier series, EN 54-4The BECS150 is a combined security battery charger andbackup supply for the DPA four family of products. TheBECS150 provides power backup during mains failure toa maximum of 6 DPA four power amplifiers and 1 backuppower amplifier. The BECS150 is equipped with heavy dutypower connectors and an isolated main battery entry forextra safety during installation. All outputs are electronicallyfused (40 A).Beside a charger for a 150 AH 24 VDC battery, theBECS150 is also equipped with a separate 150 Watt 24VDC power supply that acts as redundant backup forthe individual DPA four power amplifiers in case of aninternal power supply failure. In that case, the amplifiersare forced into sleep-mode and will continue withloudspeakerline surveillance. In case of an EVAC, theamplifiers will be forced alive for duty using the batteryback-upsupply. (Commercial use still disabled). This waythe batteries are secured for emergency applicationswith a maximum availablility for the amplifiers.BECS150Charger and monitoring unit for DPA-amplifier series for upto 6 DPAfour plus back-up amplifier and battery surveillanceand charger unit.BECS150 characteristics• 2 U high, 19-inch rack mountable.• Battery capacity: 150 AH (4x 12VDC/75AH)• 6 x 24 VDC secured outputs for DPA fourpower amplifiers.• 1x 24 VDC secured output for DPAxx back-uppower amplifier.• 3 x 24 VDC outputs for IDA4 Series, IDA8 Seriesand DIVA8 Series of routing units.• Redundant 150 W / 24 VDC powersupply.• Separate Charger for 150 AH battery.• BECS/RK - Battery charger accessory -19’’/6U Rackframe for 12VDC/75 AH batteries x4.Max carrying weight: 150 kg27


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersDPA 120 / DPA 240D-Class Amplifiers, modularDPA 1201 x 120 Watt D-Class amplifier, modularDPA 2401 x 240 Watt D-Class amplifier, modularThe DPA-series of D-Class amplifiers are thoroughly modular. Individually equipped with an AC/DC supplyand industrial cases for higher immunity, these modules are design for industrial purposes and made forfast replacements. Ready to be housed in a quick-snap 4U, 8-slot position 19-ich rack-frame.The DPA series of amplifier modules comes in two versions:120 and 240 Watt. Due to its design, 8 units can be put ina special 4U/19“ rackframe the RKDPA. In the front of eachmodule, LED indicators are showing the following status:- Power (AC/DC)- Signal- FaultGain adjustment and power-switch are positioned at the rearof each amplifier module and meant for final adjustmentduring commissioning. The D-Class design amplifier isequipped with a self-regulating ventilator with variable speedcontrol to reduce power consumption.RKDPA / Stackable rack - 4U 19” for DPAThe RKDPA 4U/19“ rackframe can carry up to 8 x DPA120or DPA240 amplifier modules. The modular concept ensuresquick parts replacement during service actions.FBDPA / 1/8 BlindpanelDPA characteristicsDPA 120• Nominal AC input voltage:115 or 230, 50/60 Hz internally selectable• Nominal DC input voltage: 24 V• DC input voltage range: 21-28 V• Idle power consumption on AC: 33 W• Idle power consumption on DC: 2 W• Power consumption, standby (AC): 57 W• Power consumption, Max (AC): 230 W• Continuous nominal output power: 120 W• Overall efficiency (DC): 70%• Frequency response (-3 dB): 30 - 20 KHz• THD nominal power -3 dB @1 kHz 22 Hz – 22 kHz:0,5%• Output: 100 V• Mains AC input socket: IEC-3• DC input socket: PHOENIX PC 6-16/2-G1-10, 16• Audio input socket: 3 pin PHOENIX 3.81 mm• Size: L55 x H 178 x D 400 mm• Net Weight: 3 Kg• Colour: Ral 7016DPA 240• Nominal AC input voltage:115 or 230, 50/60 Hz internally selectable• Nominal DC input voltage: 24 V• DC input voltage range: 21-28 V• Idle power consumption on AC: 33 W• Idle power consumption on DC: 2 W• Powerconsumption, standby (AC): 92 W• Powerconsumption, Max (AC): 437 W• Continuous nominal output power: 240 W• Overall efficiency (DC): 70%• Frequency response (-3 dB): 50 - 18 KHz• THD nominal power -3 dB @1 kHz 22 Hz – 22 kHz:0,5%• Output: 100 V• Mains AC input socket: IEC-3• DC input socket: PHOENIX PC 6-16/2-G1-10, 16• Audio input socket: 3 pin PHOENIX 3.81 mm• Size: L55 x H 178 x D 400 mm• Net Weight: 3 Kg• Colour: Ral 701628 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


AmplifiersSPA 2060 / SPA 2120 / SPA 2240AB-Class AmplifiersSPA 20602 x 60 Watt AB-Class amplifierSPA 21202 x 120 Watt AB Class amplifierThe SPA (Security Power Amplifier) is primary designed for integration into <strong>Voice</strong> <strong>Alarm</strong> systems, butthanks to its flexibility, it can also be used for any Commercial application.SPA 22402 x 240 Watt AB Class amplifierThe SPA amplifiers were specifically developed to meet therequirements of EN 60849 for safety installations. Eachamplifier module is fitted with its own 220 VAC/24 VDCpower supply for increased system reliability.To avoid handling errors, the volume output is set using thepotentiometer located at the rear of the amplifier. Furtherto standard protection via fuses, SPA amplifiers also haveelectronic and thermal protection to protect them frompotential hazards.A ventilator provides forced cooling for the final power shelvesand internal parts of the amplifier. It starts up automaticallywhen the heat shunt reaches a certain temperaturethreshold, and stops when the temperature returns to normalvalues. Four LEDs display the status of each amplifiers: AC orDC power supply, Line Overload and Temperature overload.Furthermore, a three LEDs Vu-Meter indicates the presenceand level of audio signal.A surveillance circuitry is continuously monitoring thetemperature and the presence of AC and DC power suppliesfor both amplifiers. In case of a problem, the overload LEDswill be switched ON and the Fault relay will be activated.The channels can be bridged together in order to create asingle channel amplifier with twice the power.SPA characteristicsSPA 2060• Energy supply: 220 V-24 V• Output power: 2 x 60 W• Output voltage: 8 Ω, 70 & 100 V• Power indicatie 24 V and 230 V: Yes• Frequency respond: 60 -18000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V• Fault contact(s): yes• Signal indication: YesSPA 2120• Energy supply: 220 V-24 V• Output power: 2 x 120 W• Output voltage: 8 Ω, 70 & 100 V• Power indicatie 24 V and 230 V: Yes• Frequency respond: 60 -18000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V• Fault contact(s): yes• Signal indication: YesSPA 2240• Energy supply: 220 V-24 V• Output power: 2 x 240 W• Output voltage: 8 Ω, 70 & 100 V• Power indicatie 24 V and 230 V: Yes• Frequency respond: 60 -18000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V• Fault contact(s): yes• Signal indication: Yes29


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioAmplifiersIntelligent Acoustic SolutionsLoudspeakersAB-Class mixing AmplifiersMPA 60 / MPA 120 / MPA 240The MPA line of 5-channels AB-Class mixer amplifiesare designed for use in permanent commercial soundinstallations. Versatile models are conservatively rated at 60,120 and 240 Watts RMS into 8 Ω, 70 and 100 Volt.Features include separate treble and bass controls,microphone, line and auxiliary inputs with built-in mutingcircuitry. Inputs and outputs are via dependable screwterminals, RCA jacks or XLR.All models rest on four durable cushioned pads for table-topusage and are finished in black with easy-to-read. white-onblackknobs. Output protection consists of current limiting,transient suppression diodes and circuit breakers. Modelscome with detachable 1.5 m power cord.Models were designed with the accurate reproduction ofvoice announce, paging and background music in mind.They are ideally suited for applications such as restaurants,clubs, leisure industry, factories, retail stores, churches andother public areas.The program section receives stereo inputs from CD-playeror broadcast transmission players and reproduces it inmonaural. An special AUX RCA jack is provided to receivepost preamplifier sources.MPA 6060 Watt AB-Class Mixing amplifierMPA 120120 Watt AB Class Mixing amplifierMPA 240240 Watt AB Class Mixing amplifierMPA characteristicsMPA 60• Energy supply: 220 V-24 VDC• Output power: 60 Watt• Bandwidth: 50-20000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V and AUX• Input: 5 mic/aux - 1 tel - 1 amp-return• Priority: selectable• Bass/treble: Yes• Volume regulation: Each channel + MasterMPA 120• Energy supply: 220 V-24 VDC• Output power: 120 Watt• Bandwidth: 50-20000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V and AUX• Input: 5 mic/aux - 1 tel - 1 amp-return• Priority: selectable• Bass/treble: Yes• Volume regulation: Each channel + MasterMPA 240• Energy supply: 220 V-24 VDC• Output power: 240 Watt• Bandwidth: 50-20000 Hz• Distortion: < 1%• Output: 4-8 Ω 70-100 V and AUX• Input: 5 mic/aux - 1 tel - 1 amp-return• Priority: selectable• Bass/treble: Yes• Volume regulation: Each channel + Master30 <strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsLoudspeakersATEIS STUDIOIntegrated Software PlatformATEÏS STUDIO user friendly Graphical UserAteÏs-Studio allows complete audio systems with amultitude of similar or different devices to be configured,supervised and controlled centrally from a single userinterface. AteÏs-Studio supports all IP-based productswith the AteÏs product family such as IDA, LAP,Messenger and Terracom .ATEÏS-Studio is ready for future expansion in conjunctionwith new ATEÏS products. ATEÏS-Studio also offers controland configuration for power amplifiers, microphone consolesand IP-remote controllers such as PSS-G2E, URC200.It supervises, controls, logs and reports.The whole system configuration can be stored and reloadedat the push of a button (Preset), depending upon theapplication. Customers can design their own graphic userinterface or control panel(s) as well as program automaticsequences (Events) and create different levels of usergroups. (Security).AteÏs-Studio provides a complete set of tools andbuilding blocks for real-time control, monitoring and designof an audio system or <strong>Voice</strong> Evacuation system from pagingdesk to loudspeaker. Detailed information such as signallevels, loudspeaker impedance, pre-recorded messages,amplifier conditions and other parameters can be monitoredin real-time.A library of control and monitoring elements, (GUI) graphicaluser interface, are provided and includes items such as volumecontrol faders, various metering, high level EQ, Compression,Limiting, Auto-Gain, Noise-sensing, Mixing, quick-buttonsand display elements. The behaviour of these elements arecompletely configurable for customer control design.The combination of these GUI tools allows a user to create acontrol surface that is effective, easy to operate regardlessof the user’s technical knowledge. Additional security isavailable through the use of password protected layersaccording to the EN 54-16.Multiple users can be created within AteÏs-Studio, eachwith a unique password and access to specific layers of theGUI. This creates a control surface that is specific to theneeds of any system designer and/or operators.In addition you will find a comprehensive selectionof tools for system design and programming usingour AteÏs-Studio integrated software platformfor all remote-controllable devices and systems.Screenshot 1<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>31


<strong>Public</strong> <strong>Address</strong> - <strong>Voice</strong> <strong>Alarm</strong>IPVA - IntercomCommercial AudioIntelligent Acoustic SolutionsATEÏS reserve the right to change specifications without noticeHELPROD.COM - Product pictures, Robert Peek Fotografie - References pictures : ATEÏS GROUP - Helprod.com - FotoliaATEÏS Europe B.V.Sydneystraat 42 - 3047 BP - ROTTERDAM - NETHERLANDSPhone +31 (0)10 2088690 - Fax +31 (0)10 2088699www.ateis-europe.cominfo@ateis-europe.comD e l i v e r i n g Yo u r Me s s a g e

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!