06.08.2015 Views

IBM i PowerVM Virtualization 7.1 Update

IBM i PowerVM Virtualization - Common Romandie

IBM i PowerVM Virtualization - Common Romandie

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i <strong>PowerVM</strong> <strong>Virtualization</strong> <strong>7.1</strong> <strong>Update</strong>Gottfried SchimunekSenior IT ArchitectApplication Design<strong>IBM</strong> STG SoftwareDevelopmentLab Services<strong>IBM</strong> ISV Enablement3605 Highway 52 NorthRochester, MN 55901Tel 507-253-2367Fax 845-491-2347Gottfried@us.ibm.com© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandAcknowlegements Thanks to Kris Whitney for providing this comprehensive and detailed presentation2© 2011 <strong>IBM</strong> Corporation1


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong>’s History of <strong>Virtualization</strong> LeadershipA 40+ year tradition continues with <strong>PowerVM</strong> and VM Control TM 20091967 1973 19871999 2004200720082009<strong>IBM</strong>developshypervisorthat wouldbecome VMon themainframe<strong>IBM</strong>announcesfirstmachines todo physicalpartitioning<strong>IBM</strong>announcesLPAR onthemainframe<strong>IBM</strong>announcesLPAR onPOWER<strong>IBM</strong> intro’sPOWERHypervisorfor System pand System i<strong>IBM</strong>announcesPOWER6Live PartitionMobility<strong>IBM</strong>announces<strong>PowerVM</strong>3© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>PowerVM</strong>: <strong>Virtualization</strong> Without Limits Sold with more than 70% of Power Systems Improves IT resource utilization Reduces IT infrastructure costs Simplifies management4© 2011 <strong>IBM</strong> Corporation2


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>PowerVM</strong> TechnologiesThe leading virtualization platform for UNIX, i and Linux enables amore agile and responsive infrastructure HypervisorSupport for multiple operating environments Dynamic Logical PartitioningMicro-partitioning, resource movement Multiple Shared Processor PoolsCap processor resources for a group of partitions Virtual I/O ServerVirtualizes resources for client partitions Integrated <strong>Virtualization</strong> ManagerSimplifies partition management for entry systems Lx86Supports x86 Linux applications Live Partition MobilityMove running AIX and Linux partitions System Planning ToolSimplifies the planning for and installation of Power servers with<strong>PowerVM</strong>VIOSPower Hypervisor5© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>PowerVM</strong> Editions: Built to Meet Client <strong>Virtualization</strong> Needs<strong>PowerVM</strong> EditionsExpressStandardEnterprise <strong>PowerVM</strong> Express Edition– Evaluations, pilots, PoCs– Single-server projects <strong>PowerVM</strong> Standard Edition– Production deployments– Server consolidation<strong>PowerVM</strong> Enterprise Edition– Multi-server deployments– Cloud infrastructureMaximum LPARsManagementVirtual I/O Server<strong>PowerVM</strong> Lx86Multiple SharedProcessor PoolsLive Partition Mobility1+2 / ServerVMControlIVM10 / CoreVMControlIVM, HMC10 / CoreVMControlIVM, HMCActive Memory Sharing<strong>PowerVM</strong> Editionsoffer a unifiedvirtualizationsolution for anyPower workloads6© 2011 <strong>IBM</strong> Corporation3


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i <strong>Virtualization</strong> Strategy Increased utilization of Power Systems hardware. Create a flexible infrastructure to allow for dynamic change. Begin to manage pools of systems as one.7© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandEvolution towards: Fully Virtualized, Simplified, Lower cost• Physical resource discovery / configuration /provisioning / update / system health• OS provisioning• Virtual IO• Virtual Machine lifecycle mgmt• Dynamic resource optimization within aphysical system• VLAN• External virtualized storage+ Mobility of Virtual Machines+ Manually intensive server/storage/network mobilitymanagement+ VM-based Availability/Resilience Mgmt+ Storage Pools+ IO virtualization and virtual switching+ Hypervisor clustered fs access to virtual storageSW SWOSOSVirtl NWVirt StorageVM/LPAR VM/LPAR Virtual IO Svr<strong>Virtualization</strong>StoragevSwitchNetworkCompute Memory+Mobility of workloads with automated andintegrated server, network & storageprovisioning+ Workload-based Availability/ResilienceMgmt+ Converged Datacenter Network fabric+ Storage Pools with advanced capabilities(cloning, snapshot, thin provisioning, …)+ Managing to QoS Policies (intelligentplacement)+ VM Security ApplianceImage LibraryVirtual ApplianceImageImage AppDeploymentAppImageAppOSImage OSAppOSOS• External virtualized switchesShared NetworkWorkload MobilitySWOSSWOSVirtl NWShared StorageVirtual ServerVirtual ServerVirt StorageVirtual IO SvrSWOSVirtl NW8Compute<strong>Virtualization</strong>MemoryStorageNetworkEstablished: Physical systems withlocal virtualizationVM/LPARCompute Memory<strong>Virtualization</strong>Virt StorageVirtual IO SvrvSwitchStorage NetworkMaturing: Multi-systemvirtualization managed acrossPhysical Servers11/23/2011Optimized for ….• Availability• Performance• EnergyEmerging: Virtual Appliances& Workload mobility withinscalable and centrally managedSystem Pools (Ensembles)© 2011 <strong>IBM</strong> Corporation4


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandStage 1 Flexible I/O Infrastructure Current Support with <strong>IBM</strong> i 6.1– VSCSI• Virtual Tape• Virtual Optical• Virtual Disk– VETH– <strong>IBM</strong> i server– VIOS and IVM Current Support with <strong>IBM</strong> i 6.1.1– NPIV– VIOS MPIO– SSD Enhancements– <strong>Virtualization</strong> Management Enhancements9© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsTwo I/O Server OptionsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i <strong>IBM</strong> iHypervisorPOWER6VIOS <strong>IBM</strong> iHypervisorPOWER6• Built into <strong>IBM</strong> i•Host Disk and Optical•Consolidate Ethernet Traffic•Same technology as hosting AIX,Linux, and iSCSI•VIOS Server•Host Disk and Optical•Bridge Ethernet Traffic•Attach external storage•Advance <strong>Virtualization</strong> Functions10© 2011 <strong>IBM</strong> Corporation5


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i Hosting <strong>IBM</strong> i<strong>IBM</strong> i-based <strong>Virtualization</strong>– <strong>IBM</strong> i partition uses I/O resources from another <strong>IBM</strong> ipartition– Eliminates requirement to buy adapters and disk drivesfor each <strong>IBM</strong> i partition– Supports simple creation of additional partitions …. e.g.,for test and development– Requires POWER6 server with <strong>IBM</strong> i 6.1– <strong>PowerVM</strong> not required– Can mix virtual and direct I/O in clientPlatform support– <strong>IBM</strong> POWER6 and POWER7 servers (except blade)Storage support– Determined by host <strong>IBM</strong> i partition (SAN, EXP24, 12S,other integrated disk)LPAR management– HMC<strong>IBM</strong> i <strong>IBM</strong> iHypervisorPOWER6* All statements regarding <strong>IBM</strong>'s future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.11© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i Host and Client Partitions: OverviewFC 5294EXP24/12SDS8000NWSSTGsOPTxxIVE<strong>IBM</strong> i HostDVDDDxxVirtual SCSIconnectionVirtual LANconnection<strong>IBM</strong> i ClientOPTxxCMNxxDDxxDVD Requirements– POWER6 hardware– <strong>IBM</strong> i 6.1 on host and client– <strong>PowerVM</strong> not required– HMC DASD– Hardware assigned to host LPAR inHMC– DASD can be integrated or SAN– DASD virtualized as NWSSTG objects Optical– DVD drive in host LPAR virtualizeddirectly (OPTxx)– Optical IMGCLG in host LPAR may bevirtualized Networking– Network adapter (such as IVE) andVirtual Ethernet adapter in host LPAR– Virtual Ethernet adapter in client LPAR12© 2011 <strong>IBM</strong> Corporation6


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i Host VSCSI Virtual Optical-Load images into the IMGCLG onthe Server.- Share the physical DVD/CD in theServer-Utilize them to install or save to in theClient.-Automatic switching of images13© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power Systems<strong>IBM</strong> or BP image or…Physical mediaRipping toolNovember 16, 2011 — Geneva, SwitzerlandCurrent (v6.1, pre 4Q’09)• supports loads of LPs, PTFs and data onto a v6.1 partition4Q’09• upgrade/scratch ibm i v6.1.1 over existing 6.1 partition• advantages• OS install over LAN• single copy of image• breaks single CEC/PHYP limit• requires: v6.1.1, phyp efw 3.5 and power 6ElectronicsoftwaredistributionNFS ‘image’NFS ‘image’NFS Server(most any serverexcept VIOS)2Q ’10• support for ibm i v<strong>7.1</strong>• addition of power 74Q’10• scratch install of new partition• requirements• phyp efw 3.5 (or later)• power 6 or power 7• HMC 7.7.2 (or later) or DPSMPower systemibm i v6.1 (CRTDEVOPT *SRVLAN)SAVSYS, SAVOBJ,SAVLICPGM…14© 2011 <strong>IBM</strong> Corporation7


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i Hosting <strong>IBM</strong> i PositioningSame technology as <strong>IBM</strong> i hosting AIX, LINUX, andiSCSI x86 serversLeverage existing hardware investment– Create new <strong>IBM</strong> i 6.1 LPARs using only virtualhardware (No IOAs, IOPs, disk units, I/O slotsnecessary for client partitions), but may also usephysical I/O.Rapidly deploy new workloads– Virtual disk created with 1 command or severalclicks in System i Navigator– New LPAR, virtual resources deployeddynamicallyCreate test environments without hardwareprovisioning– Virtual resources allow new test environments of exactsize to be created, deleted without moving hardware– Test new applications, tools, fixes in virtual test LPAR– Test the next release in the client partition<strong>IBM</strong> i <strong>IBM</strong> iHypervisorPOWER6* All statements regarding <strong>IBM</strong>'s future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.15© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVIOS-based <strong>Virtualization</strong>– <strong>IBM</strong> i partition uses I/O resources from Virtual I/OServer (VIOS)– VIOS is included with all <strong>PowerVM</strong> Editions.– Requires POWER6 systems with <strong>IBM</strong> i 6.1Platform support– <strong>IBM</strong> Power servers– <strong>IBM</strong> BladeCenter JS12 , JS22, JS23, JS43, PS701,PS702Storage support– Enables attachment to DS3000, DS4000, DS5000,SVC, XIV, DS8000LPAR management– HMC or IVMVIOS <strong>IBM</strong> iHypervisorPOWER6Integrated <strong>Virtualization</strong> Manager– Software for creating and managingpartitions, part of VIOS– Requires <strong>IBM</strong> i to use only virtual I/Oresources16© 2011 <strong>IBM</strong> Corporation8


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVirtual I/O Server (VIOS) Disk<strong>IBM</strong> i-VSCSI disks are always 6B22-16 disks per virtual adapter-Thousands of virtual adaptersDD001(6B22)vtscsi1hdisk1(2107)VIOSDD002DD003(6B22)vtscsi2vtscsi3Storage Pool 1hdisk2 (1815)hdisk2hdisk3(1815)(1815)hdisk3 (1815)hdisk4 (1815)hdisk4 (1815)-Flexible LUN sizes-Logical volume backed-File BackedDS8300DS480017© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandDisk <strong>Virtualization</strong> with VSCSI1 Use storage UI and Redbook for your environment to create LUNs for <strong>IBM</strong> i and attach to VIOS (or use TPC or SSPCwhere applicable)– 512B open storage LUNsDS Storage Manager forDS3200, DS3400, DS4700,DS4800, DS5100, DS5300DS8000 Storage Managerfor DS8100 and DS8300SVC Console forSVCXIV Storage GUI forXIV18© 2011 <strong>IBM</strong> Corporation9


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandDisk <strong>Virtualization</strong> with VSCSIVIOS2<strong>IBM</strong> i Use HMC to create one or more pair of VSCSI adapters– VSCSI server in VIOS, VSCSI client in <strong>IBM</strong> i– DLPAR-capable19© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandDisk <strong>Virtualization</strong> with VSCSI3 Use HMC to assign LUNs to <strong>IBM</strong> i LPAR (DLPAR-capable)20© 2011 <strong>IBM</strong> Corporation10


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>Virtualization</strong> Enhancements for <strong>IBM</strong> i1. <strong>IBM</strong> i 6.1 partition can host<strong>IBM</strong> i <strong>7.1</strong> and 6.1 partitions AIX 5.2, 5.3, 6.1 and SLES and Red Hat Linux partitions iSCSI attached System x and BladeCenter1. <strong>IBM</strong> i <strong>7.1</strong> partition can host<strong>IBM</strong> i <strong>7.1</strong> and 6.1 partitionsAIX 5.2, 5.3, 6.1 and SLES and Red Hat Linux partitionsiSCSI attached System x and BladeCenter2. <strong>PowerVM</strong> VIOS can host<strong>IBM</strong> i <strong>7.1</strong> and 6.1 partitionsAIX and Linux partitionsVIOS supports advanced virtualization technologiesincluding Active Memory Sharing and NPIVStorage <strong>Virtualization</strong> can reduce costswhile improving IT infrastructure flexibilityVIOS<strong>IBM</strong> i 6.1VIOS<strong>IBM</strong> i <strong>7.1</strong>VIOSVIOS<strong>IBM</strong> i <strong>7.1</strong> <strong>IBM</strong> i 6.1POWER6 & POWER7VIOS<strong>IBM</strong> i <strong>7.1</strong> <strong>IBM</strong> i 6.1POWER6 & POWER7VIOS<strong>IBM</strong> i <strong>7.1</strong> <strong>IBM</strong> i 6.1POWER6 & POWER721© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVIOS VSCSI Virtual Optical<strong>IBM</strong> i-Support for Physicaland File BackedOptical (FBO) Drives.OPT01(632C)vtscsi1VIOSOPT02(632C)vtscsi2Storage Pool 1- Read Only imagesmay be shared tomultiple virtual opticaldrives concurrently.CD0File BackedImageshdisk2 (1815)hdisk3 (1815)hdisk4 (1815)22© 2011 <strong>IBM</strong> Corporation11


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandSupport for <strong>IBM</strong> Storage Systems with <strong>IBM</strong> iTable as ofFeb 10, 2011N Series@@DS3200DS3400DS3500DS3950DS4700DS4800DS5020StorwizeV7000DS5100DS5300DS6800SVCXIVDS8100DS8300DS8700DS88006.1 / <strong>7.1</strong>5.4 / 6.1Rack /TowerSystems<strong>IBM</strong> iVersionHardware5.4 / 6.1 / <strong>7.1</strong>POWER5/6/7POWER6/7NOT DS3200#DS3500##6.1 / <strong>7.1</strong>POWER6/76.1 / <strong>7.1</strong>POWER6/76.1 / <strong>7.1</strong>POWER6/7POWER5/6/7Not <strong>7.1</strong> ###POWER5/6/76.1 / <strong>7.1</strong>POWER6/76.1 / <strong>7.1</strong>POWER6/75.4 / 6.1 / <strong>7.1</strong>POWER5/6/75.4 / 6.1 / <strong>7.1</strong>POWER5/6/7<strong>IBM</strong> iAttachIFS/NFS(NAS)VIOSVIOSVIOSDirect* or VIOSDirectVIOSVIOSDirect or VIOSNPIV**Direct or VIOSNPIV**PowerBlades<strong>IBM</strong> iVersionHardware6.1 / <strong>7.1</strong>POWER6/7IFS/NFS(NAS)6.1 / <strong>7.1</strong>POWER6/7 @6.1 / <strong>7.1</strong>POWER6/7(BCH)6.1 / <strong>7.1</strong>POWER6/7(BCH)Notes <strong>IBM</strong> i IFS/NFSVIOSVIOSVIOS VIOS VIOS VIOSn/aVIOS VIOS- This table Attach does not list (NAS) more detailed considerations, for example required levels of firmware or PTFs required or configuration performance NPIV** considerations NPIV**- POWER7 servers require <strong>IBM</strong> i 6.1 or later- This table can change over time as addition hardware/software capabilities/options are added# DS3200 only supports SAS connection, not supported on Rack/Tower servers which use only Fibre Channel connections## DS3500 has either SAS or Fibre Channel connection. Ractk/Tower only uses Fibre Channel. Blades support either SAS or Fibre Channel### Not supported on <strong>IBM</strong> i <strong>7.1</strong>. But see SCORE System RPQ 846-15284 for exception support* Supported with Smart Fibre Channel adapters – NOT supported with IOP-based Fibre Channel adapters** NPIV requires Machine Code Level of 6.1.1 or later and requires NPIV capable HBAs (FC adapters) and switches@ BCH supports DS3400, DS3500, DS3950 & BCS supports DS3200, DS3500@@ N Series can only be used as file server. No load source/boot support. Support only through IFS. No <strong>IBM</strong> i data base support6.1 / <strong>7.1</strong>POWER6/7(BCH)Notsupported6.1 / <strong>7.1</strong>POWER6/7(BCH)6.1 / <strong>7.1</strong>POWER6/7(BCH)6.1 / <strong>7.1</strong>POWER6/7(BCH)6.1 / <strong>7.1</strong>POWER6/7(BCH)For more details, use the System Storage Interoperability Center: www.ibm.com/systems/support/storage/config/ssic/Note there are currently some differences between the above table and the SSIC. The SSIC should be updated to reflect the above information23© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandDS8300 Native, Through VIOSCPW ApplicationResponse Tim e (Milliseconds)504540353025201510500 50000 100000 150000 200000 250000Throughput (Transactions /Minute)DS8k nativeDS8k via VIOSResponse Tim e(Milliseconds)CPW DB Disk Data Rate1210864200 50 100 150 200Throughput (MB/Sec)Response Time(Milliseconds)CPW JO Disk Data Rate21.81.61.41.210.80.60.40.200 20 40 60 80 100Throughput (MB/Sec)DS8k nativeDS8k via VIOSDS8k nativeDS8k via VIOS24© 2011 <strong>IBM</strong> Corporation12


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>PowerVM</strong> Active Memory Sharing <strong>PowerVM</strong> Active Memory Sharing is an advanced memoryvirtualization technology which intelligently flows memory from onepartition to another for increased utilization and flexibility of memoryusage Memory virtualization enhancement for Power Systems– Partitions share a pool of memory– Memory dynamically allocated based on partition’s workloaddemands Extends Power Systems <strong>Virtualization</strong> Leadership– Capabilities not provided by Sun and HP virtualization offerings Designed for partitions with variable memory requirements– Workloads that peak at different times across the partitions– Active/inactive environments– Test and Development environments– Low average memory requirements Available with <strong>PowerVM</strong> Enterprise Edition– Supports AIX 6.1, i 6.1, and SUSE Linux Enterprise Server 11– Partitions must use VIOS and shared processors– POWER6 processor-based systemsMemory Usage (GB)Memory Usage (GB) Memory Usage (GB)151050151050151050Around the WorldTimeDay and NightTimeInfrequent UseTimeAsiaAmericasEuropeNightDay#10#9#8#7#6#5#4#3#2#125© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandAMS Geographic Mirroring EnvironmentSASJS12 in BladeCenterDS3200VIOS <strong>IBM</strong> i <strong>IBM</strong> iDS3200DS3KBCS3B2P1PagingDevicesBCS3B2P2BCS3B2P3MEMORY5 drivesysbas5 drivesysbas16 GB TotalPhysicalMem<strong>IBM</strong> i 112 GB<strong>IBM</strong> i 212 GB10 drivesIASPGeographicMirroring10 drivesIASP26© 2011 <strong>IBM</strong> Corporation13


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVirtual Tape with VSCSI+• GAed 5/2009 <strong>IBM</strong> i 6.1 + ptfs• LTO4, DAT72, DAT160• All BRMS and Save/Restore function available.• Library support not available with VSCSI, must use NPIV• Also supported on non-blade Power Systems27© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandFibre Channel Tape library support with NPIV+28•10/2009 with 6.1.1•3584 (TS3500) with LTO drives•3573 (TS3100 TS3200) with LTOdrives•2/2010 with 6.1.1•3577 (TS3400) with (TS1120/TS1130 ) drives•3584 (TS3500) with (TS1120/TS1130 ) drives•3576 (TS3310) with LTO drives•TS7650, TS7610© 2011 <strong>IBM</strong> Corporation14


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandSSD with VIOS Ability to share an array of SSDs among multiple partitions.– With 6.1.1 <strong>IBM</strong> i will recognize the drive as SSD– Also can be used as a shared memory pool paging device.<strong>IBM</strong> iDD001(6B22 HDD)DD002DD003(6B22 SSD)vtscsi1hdisk1HDDVIOSvtscsi2vtscsi3Storage Pool 1hdisk2 (SSD)hdisk3 (SSD)hdisk4 (SSD)29© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i Multi Path I/O Support<strong>IBM</strong> iDD001(6B22)vtscsi1hdisk1(2107)VIOSOption 1Multipath from the VIOS out to theexternal storage box.FCS0FCS1lun130© 2011 <strong>IBM</strong> Corporation15


<strong>IBM</strong> Power Systems<strong>IBM</strong> i Multi Path I/O SupportNovember 16, 2011 — Geneva, SwitzerlandDD001(6B22)<strong>IBM</strong> iLogically mirrored disk Option 2DD002(6B22)-HMC managed systems-Mirroring across 2 VIOS LPARs- 2 copies of the datavtscsi1 VIOS 1hdisk1(2107)vtscsi1VIOS 2hdisk3(2107)FCS0FCS1FCS0FCS1lun1lun231© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power Systems<strong>IBM</strong> i Multi Path I/O SupportNovember 16, 2011 — Geneva, SwitzerlandDD001(6B22)<strong>IBM</strong> iDMP001DD002(6B22)- MPIO support across2 VIOS LPARs (with HMC)- 1 copy of the datavtscsi1 VIOS 1hdisk1(2107)vtscsi1VIOS 2hdisk3(2107)FCS0FCS1FCS0FCS1lun132© 2011 <strong>IBM</strong> Corporation16


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i + NPIV ( Virtual Fiber )System 1SourceSystem 2VIOS8Gbs HBA<strong>IBM</strong> i Client(System 1)<strong>IBM</strong> i Client(System 1)<strong>IBM</strong> i Client(System 1)System 3•Hypervisor assigns 2 uniqueWWPNs to each Virtual fiber•Hostconnect is created as aniSeries hosttype,•Requires 520 byte per sector LUNsto be assigned to the iSerieshostconnect•Can Migrate existing direct connectLUNSVirtual address example C001234567890001HypervisorPOWER6 with <strong>IBM</strong> i 6.1.1Note: Not available on blades until 4/2010Note: an NPIV ( N_port ) capable switch is required to connect theVIOS to the DS8000 to use virtual fiber.33© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandNPIV Configuration - Server Adapter Mappings34© 2011 <strong>IBM</strong> Corporation17


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland<strong>IBM</strong> i + NPIV ( Virtual Fiber ) with PowerHASourceSYSBASVIOS 1VIOS8Gbs HBAVIOS 2 <strong>IBM</strong> i Client 1IASP8Gbs HBAEach port is assigned separateWWPNs by the HypervisorEach port is seen as a separateadapter by <strong>IBM</strong> i – so PowerHA reset itindividually.Reduces the hardware for a singlepartition from 4 to 2 adapters forPowerHAHypervisorPOWER6 with <strong>IBM</strong> i 6.1.1•Note, This configuration can support up to 64 <strong>IBM</strong> i partitions without addingany more adapters35© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandNPIV Performance (work in progress)NPIV vs Direct Attach (DS8300)Application Response Time0.010.0090.0080.0070.0060.0050.0040.0030.0020.00100 20 40 60 80 100 120CPW Use rsnpiv run2direct attach36© 2011 <strong>IBM</strong> Corporation18


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandPowerHA in the Virtual I/O Environment With VSCSI– All Logical replication solutions supported including iCluster– PowerHA for i - Geographic mirroring With NPIV– Metro Mirroring– Global Mirroring– Lun level switching37© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVIOS <strong>Virtualization</strong> PositioningExtend <strong>IBM</strong> i storage portfolio– Existing investment in DS4000,SVC storage– Allows consolidation of <strong>IBM</strong> i into existing SAN– Lower end SAN attachment DS3000– New XIV attachmentExisting VIOS environment– <strong>Virtualization</strong> platform of choice is VIOS– <strong>IBM</strong> i workloads can participate in existingvirtualization environmentVIOS <strong>IBM</strong> iHypervisorPOWER6Positioning for future <strong>PowerVM</strong> advancedfunctions.Required for Blades.Provides lightweight partition management.38© 2011 <strong>IBM</strong> Corporation19


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandVIOS 2.2 - Integrated Storage <strong>Virtualization</strong>Integrated Storage <strong>Virtualization</strong> increases Platform ValueClient Benefits• Automated storage provisioning•Non-disruptive • Few interactions storage lifecycle between management mgmt domains• Simplified, integrated Director Mgmt •Director • Consolidated integration to deliver on-line high level backup values= Decreased complexity and cost• Advanced image management •Storage integrated with Server Mgmt Infrastructures• Consistent capabilities with different storage•Consistent capabilities across different storageServer SystemAdministratorsAdminVirtual ServersStorage SystemAdministratorsSAN39Servers…AdminServers…CPUMemoryStorageVIOSCPUMemoryStorageSynerStorIntegratedServer &StorageManagementVIOSIntegrated Storage CapabilitiesStorage AggregationPhysical Storage administrationStorage MobilitySnapshots & clonesThin Provisioning<strong>IBM</strong>, EMC, Hitachi, Other SANStorage pooling SAN <strong>Virtualization</strong>Migration File <strong>Virtualization</strong>Copy services CachingThin provisioning Geo mirroringNASSOFS, NetApp, EMC, Other NASHeterogeneous© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland Questions40© 2011 <strong>IBM</strong> Corporation20


<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, Switzerland41© 2011 <strong>IBM</strong> Corporation<strong>IBM</strong> Power SystemsNovember 16, 2011 — Geneva, SwitzerlandTrademarks and Disclaimers8 <strong>IBM</strong> Corporation 1994-2008. All rights reserved.References in this document to <strong>IBM</strong> products or services do not imply that <strong>IBM</strong> intends to make them available in every country.Trademarks of International Business Machines Corporation in the United States, other countries, or both can be found on the World Wide Web athttp://www.ibm.com/legal/copytrade.shtml.Adobe, Acrobat, PostScript and all Adobe-based trademarks are either registered trademarks or trademarks of Adobe Systems Incorporated in the United States, othercountries, or both.Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are trademarks or registeredtrademarks of Intel Corporation or its subsidiaries in the United States and other countries.Linux is a registered trademark of Linus Torvalds in the United States, other countries, or both.Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States, other countries, or both.IT Infrastructure Library is a registered trademark of the Central Computer and Telecommunications Agency which is now part of the Office of Government Commerce.ITIL is a registered trademark, and a registered community trademark of the Office of Government Commerce, and is registered in the U.S. Patent and Trademark Office.UNIX is a registered trademark of The Open Group in the United States and other countries.Cell Broadband Engine and Cell/B.E. are trademarks of Sony Computer Entertainment, Inc., in the United States, other countries, or both and are used under licensetherefrom.Java and all Java-based trademarks are trademarks of Sun Microsystems, Inc. in the United States, other countries, or both.Other company, product, or service names may be trademarks or service marks of others.Information is provided "AS IS" without warranty of any kind.The customer examples described are presented as illustrations of how those customers have used <strong>IBM</strong> products and the results they may have achieved. Actualenvironmental costs and performance characteristics may vary by customer.Information concerning non-<strong>IBM</strong> products was obtained from a supplier of these products, published announcement material, or other publicly available sources and doesnot constitute an endorsement of such products by <strong>IBM</strong>. Sources for non-<strong>IBM</strong> list prices and performance numbers are taken from publicly available information,including vendor announcements and vendor worldwide homepages. <strong>IBM</strong> has not tested these products and cannot confirm the accuracy of performance, capability, orany other claims related to non-<strong>IBM</strong> products. Questions on the capability of non-<strong>IBM</strong> products should be addressed to the supplier of those products.All statements regarding <strong>IBM</strong> future direction and intent are subject to change or withdrawal without notice, and represent goals and objectives only.Some information addresses anticipated future capabilities. Such information is not intended as a definitive statement of a commitment to specific levels of performance,function or delivery schedules with respect to any future products. Such commitments are only made in <strong>IBM</strong> product announcements. The information is presented hereto communicate <strong>IBM</strong>'s current investment and development activities as a good faith effort to help with our customers' future planning.Performance is based on measurements and projections using standard <strong>IBM</strong> benchmarks in a controlled environment. The actual throughput or performance that anyuser will experience will vary depending upon considerations such as the amount of multiprogramming in the user's job stream, the I/O configuration, the storageconfiguration, and the workload processed. Therefore, no assurance can be given that an individual user will achieve throughput or performance improvementsequivalent to the ratios stated here.Prices are suggested U.S. list prices and are subject to change without notice. Contact your <strong>IBM</strong> representative or Business Partner for the most current pricing in yourgeography.42© 2011 <strong>IBM</strong> Corporation21

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!