Crompton Meter Relays• Monitors and Controls Any Variable Which Can be ConvertedInto an AC or DC Signal• Rugged Shock and Vibration Resistant Design• Indicator, Relays and Power Unit in One Housing• Control Function Continues if the Indicator Becomes Damaged• Stable Electronic Switching Circuit Does Not Use Lamps,Photocells, Inductors or Capacitors• Taut Band, Fluid Damped Indicator• Isolate Input Signal• LED Relay State IndicatorsSeries 239 and 077 meter relays combine a highly accurate indicatorwith High and Low set point relays. The relays can operate alarm andcontrol devices when the monitored signal value moves outside thechosen set point limits shown by adjustable re index pointers.A single compact case houses the unit which requires only the inputsignal and power supply thus saving space and installation time.<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>External Power SupplyAn External AC or DC supply is required for operation of all MeterRelays and must be specified at the time of ordering.AC – Standard Unit will accept 120V or 240V, 60 Hz(Selectable internally at factory)DC – 12V, 24V, 48V and125V DCNote: External Supplies derived from rectified AC must beexternally filtered to minimize Ripple Content.Scales:Standard Scales may be selected from the 1, 1.5, 2, 3, 4, 5, 6, 8,10 and multiples of 10 or 100 in standard face type. Any captionusing standard face type may be specified. Center zero scales arestandard where the end value is listed in the above series.Relay State Indicators:Red LED relay state indicators are fitted in dial as standard at noextra charge.SPECIFICATIONSInput Signal RatingsFrequency Monitoring: 45/65 Hz or 55/65 HzDC Voltage:10 mV to 800V, 10 ohm/vDC Current:1 uA to 15A, 20 mV dropAC Voltage:10V to 600V 10K ohm/vAC Current:1A to 15A, 5A CT OperationThermocouples: Standard Outputs Min. 10 mV SpanRTD Operation: 10 Ohm Copper, 100 Ohm PlatinumOverloads:1.2 x continuous, up to 200V or 100 mA10 x for 10 secondsDamping Time: 1 SecondOperating Time: 250 m/sec to 10 sec adjustableRelay Operation: SPDT contact on each setpointContact Rating: 5A, 250V, 1000W non-inductiveOrdering Information:Due to the Versatility of this product it is difficult to list thecomplete part numbers for all the various functions. Pleaseprovide the basic catalog number listed above, along with input,scale, frequency, external power supply, and any options (seetable below) you may require. We will then generate a completepart number.73<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


Crompton Meter Relays<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>239 SERIES ORDERING INFORMATION239-302A 2 Output Relays, 2 Set Points, High/Low Control239-301A 1 Output Relay, 1 Set Point, High Control Only239-307A 1 Output Relay, 1 Set Point, Low Control Only239-300A 1 Output Relay, 2 Set Points, High/Low Control239-30TA 2 Output Relays, 2 Set Points, High/Low Control, Thermocouple ApplicationsFitted with Cold Junction Compensation Circuitry239-30RA 2 Output Relays, 2 Set Points as 239-30TA but for RTD Applications239-304A 2 Output Relays, 2 Set Points, High Relay Downscale Energized,Low Relay Upscale Energized239-305A 2 Output Relays, 2 Set Points, both Relays Downscale EnergizedNote: Specify Calibration Information (See below Ordering Information)077 SERIES ORDERING INFORMATION077-302A 2 Output Relays, 2 Set Points, High/Low Control077-301A 1 Output Relay, 1 Set Point, High Control Only077-307A 1 Output Relay, 1 Set Point, Low Control Only077-300A 1 Output Relay, 2 Set Points, High/Low Level Control077-30TA 2 Output Relays, 2 Set Points, High/Low Control, Thermocouple Applications(Specify Type), Fitted with Cold Junction Compensation Circuitry077-30RA 2 Output Relays, 2 Set Points, as 077-30TA, but for R.T.D. Applications(Specify 10 ohm Copper or 100 ohm Platinum)077-303A 2 Output Relays, 2 Set Points, both Relays Upscale Energized077-304A 2 Output Relays, 2 Set Points, High Relay, Downscale Energized,Low Relay Upscale Energized077-305A 2 Output Relays, 2 Set Points, both Relays Downscale EnergizedNote: Specify Calibration Information (See below Ordering Information)OPTIONAL EXTRASDescriptionCode4-20 mADC Suppressed Zero Input HG5 AAC input - A 5A/10A internal CT is fitted permitting connection tothe secondary of any of an external instrument transformerLSLatching on both relays (specify reset operation)ConsultMirror DialConsultThumb Screw Set Point Adjuster(s)FKExpanded ScaleOff-Set Zero ScaleTime Proportional Control-Models 239-30T and 239-30RATPExtended Operating Temperature Range (-25 to +60°C)ET12V, 24V, 48V External Power MU, BD, BE125 VDC External Poewer BIRetrofit Mounting Plate Allows Model 239 to be mounted in place ofModel 237 using same holesRPDouble Pole, Double throw relays have 0.3 to 20 Second Adjustable Time Delay as StandardOther options and special features available upon request239 ▲077 ▲<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com74


Weschler Process Loop Splitter• Three Separate 4 mA to 20 mA Outputs• Low-Cost Alarm Meter Option• DIN Rail Mounting• Screw Terminal Connections• Low Input ResistanceThe TIM-018 allows one 4 to 20 mA signal tobe split into three completely independent,though identical, loops that have no influenceon each other at all. Each output has its ownzero and span adjustment potentiometers.<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>• Flexible and Simple Scaling• Excitation Output• 110V or 240V AC Supply• High Drive CapacityThe units are shipped as standard with allthree loops mirroring the input exactly.The unit’s auxiliary excitation supply can beused to drive a 2-wire transmitter.TIM-018▲SPECIFICATIONSInputInput Signal:4 mA–20 mA, 0–20 mAInput Resistance:50ΩExcitation Supply for I/P Sensor: 20 VDCSpeed of Response:200 millisecondsIsolation from Supply and Earth: 1 kVOutputNumber of Outputs: 3Adjustability:Zero ±1 mA, span ±9 mALoop Drive Capacity:600Ω per loopPower SupplyDefault Shipping Voltage:110 VAC ±15% (3 watts max)Supply Voltage on Request: 240 VAC ±15%EnvironmentalOperating Temperature:0–50°CHumidity:90% RH max, noncondensingTo Order—Insert Number Code for Each Letter to Select Catalog NumberOrder Example: TIM-018-A-21-FS(0-1500)A – B – C – DABCDORDERING INFORMATIONBasic UnitTIM-018 Loop Splitter TransmitterSupplyA 110 VACB 240 VACInput Range21 4–20 mADC20 0–20 mADCScalingS Standard (input range and scale are the same)FS Factory Scaling (custom—specify scaling)Pyragon Universal Process I/O Module• Direct Replacement for Transmation 3000 Series Modules• Universal Input Includes TC, RTD, mADC, mVDC• 4 Digit Alpha-Numeric LED Display• Input Isolated from Output and Power• 4 Year WarrantyP3100P3100-WOCP3100TORDERING INFORMATIONAlarm/Transmitter in Metal CaseAlarm/Transmitter w/o caseTransmitter OnlyThe P3100 accepts a wide variety of inputs.The 4 digit display provides a local readout.Use the P3100 in a new installation or toreplace existing 3000 series units.P3100▲Models Replaced: 3510A, 3520A, 3530A, 3540A, 3610A, 3620A, 3630A,3640A, 3650A, 3660A, 3510DRA, 3520DRA, 3530DRA, 3540DRA,3610DRA, 3620DRA, 3630DRA, 3640DRA, 3650DRA, 3660DRA,3510T, 3530T, 3610T, 3630T, 3650T, 3900F, 3909FInput TypesThermocouple:J, K, T, E, R, S, B, L, U, N, RTD(2 or 3 wires): 100Ω Pt (α.00385, .00392, .003916);200, 500 & 1000Ω Pt (α.00385): 120Ω Ni and 10Ω CuCurrent:±20 & ±50mA DC rangesVoltage:±1 & ±10V DC rangesMillivolts:±70mVPotentiometer (3 wire) & Resistance (2 wire): 50, 200 & 2000 rangesFrequency:Counts/minute, Hz & kHz rangesSPECIFICATIONSSignal Output: 4-20mA DC (600Ω Load) or 1-5V DC, 10-50mA DC optionalLED Display: 4-Digit Alphanumeric, Decimal Point Configurable for0, 1st, 2nd or 3rd placeFront Panel Buttons:Relay Trip & Recovery parameters,Relay states override, Latch reset and output manual modeAnalog Accuracy:0.1% of Span or 10mV referred to inputLoop Power: 24VDC supply to power input mA signals up to 21mADPDT Relay:Configurable delay & latchingWorking Voltage:300VAC Input to Output to Input PowerIsolation:1000VDC Input to Output to Input PowerConfiguration Interface:RS232, 1200 BAUD, ASCII half duplexOperating Temperature:0-50°CPower (jumper selectable): 100–240VAC, 50/60Hz and 24VDC ±10%<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com86


<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>Crompton AC Current and Voltage Transducers• CE Compliant (CE Marked)• Flexible Design with up to Three Transducersin One Housing• UL Approved• Enclosure to IEC529 (IP50)• Flame Retardant• 35 mm DIN Rail Mount or Key Hole SlotsAC Current, Voltage, Frequency and DC• Average Sensing and True RMS• Self Powered and Auxiliary• Current Measuring to 0.5% Accuracy• Isolated Input and Output253▲AC CURRENTInput Auxiliary Power Output Catalog NumberAC Current—Average Sensing, Single-Phase 5A AC/60 Hz Self 0–1 mADC 253-TAAU-LSFA-C65A AC/60 Hz 120 VAC 4–20 mADC 253-TALU-LSHG-C6-DGAC Current—Average Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz 120 VAC 0–1 mADC 256-TASU-LSFA-C6-DG5A AC/60 Hz 120 VAC 4–20 mADC 256-TALU-LSHG-C6-DGAC Current—True RMS Sensing, Single-Phase 5A AC/60 Hz 120 VAC 0–1 mADC 253-TARU-LSFA-C6-DGAC Current—True RMS Sensing, 3-Phase, 3 DC Outputs 5A AC/60 Hz 120 VAC 0–1 mADC 256-TARU-LSFA-C6-DGAC Current—Bi-Directional 5A AC/60 Hz Self ±1 mADC 256-TABU-LSM1-C6-PQ-T3AC VOLTAGEInput Auxiliary Power Output Catalog NumberAC Voltage—Average Sensing, Single-Phase120 VAC/60 Hz Self 0–1 mADC 253-TVAU-PQFA-C6120 VAC/60 Hz 120 VAC 4–20 mADC 253-TVLU-PQHG-C6-DGAC Voltage—True Sensing, Single-Phase120 VAC/60 Hz 120 VAC 0–1 mADC 253-TVRU-PQFA-C6-DGAC Voltage—True RMS Sensing, 3-Phase, 3 DC Outputs120 VAC/60 Hz 120 VAC 0–1 mADC 256-TVRU-PQFA-C6-DGInput System Output Catalog NumberAC Voltage—Average Sensing, 3-Phase, 3 DC Outputs120 VAC/60 Hz 3-Phase, 3-Wire 4–20 mADC 256-TVLU-PQHG-C6-DG120 VAC/60 Hz 3-Phase, 4-Wire 0–1 mADC 256-TVSU-PQFA-C6-DGInput Auxiliary Power Output Catalog NumberAC Voltage—Suppressed Zero AC, Expanded Scale108–132 VAC Self 0–1 mADC 253-TVZU-A9FA-C6FREQUENCYInput Frequency Output Catalog Number120 VAC 45–55 Hz 0–1 mADC 253-THZU-PQFA-AG120 VAC 55–65 Hz 0–1 mADC 253-THZU-PQFA-AN120 VAC 45–65 Hz 0–1 mADC 253-THZU-PQFA-AJ120 VAC 360–440 Hz 0–1 mADC 253-THZU-PQFA-BI96<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


Crompton TransducersAC Power Transducers• Wide Range of Transducers to Measure All Forms of Power• Available in Single-Phase, 3-Phase 3- or 4-Wire• Self Powered Units Permit Voltage Variations Up to 20% ofNominal Input• Measures both Import and Export Power<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>97DC/DC & TEMPERATUREInput Auxiliary Power Output Catalog NumberDC Current 120 VAC 0–1 mADC 256-TTAU-**FA-DGDC Millivolts 120 VAC 0–1 mADC 256-TTMU-**FA-DGDC Voltage 120 VAC 0–1 mADC 256-TTVU-**FA-DGK Thermocouple 120 VAC 0–1 mADC 256-TTNU-KTFA-DGT Thermocouple 120 VAC 0–1 mADC 256-TTCU-TTFA-DGJ Thermocouple 120 VAC 0–1 mADC 256-TTFU-JTFA-DG10 Ohm Cu, RTD 120 VAC 0–1 mADC 253-TRRU-R1FA-DG100 Ohm Plt. RTD 120 VAC 0–1 mADC 253-TRRU-R2FA-DGAC WATTSSystem Input Type Output Catalog NumberAC Watts (Active Power)1 Ph, 2 Wire 120V/5A 1 Element 0-1 mADC 256-TWKU-QQFA-C6-**1 Ph, 3 Wire 240V/10A 1 Element 0-1 mADC 256-TWKU-Q8FA-C6-**3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TWMU-QQFA-C6-**3 Ph, 4 Wire 120V/5A 2 1 /2 Element 0-1 mADC 256-TWNU-QQFA-C6-**** Specify RangeAC VARS (Reactive Power)1 Ph, 2 Wire 120V/5A 1 Element 0-1 mADC 256-TXKU-QQFA-C6-**1 Ph, 3 Wire 240V/10A 1 Element 0-1 mADC 256-TXKU-Q8FA-C6-**3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TXMU-QQFA-C6-**3 Ph, 4 Wire 120V/5A 2 1 /2 Element 0-1 mADC 256-TXNU-QQFA-C6-**** Specify RangeAC VA (Apparent Power)1 Ph, 3 Wire 120V/10A 1 Element 0-1 mADC 256-TYKU-QQFA-C6-**3 Ph, 3 Wire 120V/5A 2 Element 0-1 mADC 256-TYMU-QQFA-C6-**3 Ph, 4 Wire 120V/5A 2 1 /2 Element 0-1 mADC 256-TYNU-QQFA-C6-**** Specify RangePower Factor (Suits Analog Meters)1 Ph, 2 Wire 120V/5A 0.5-1-0.5 1-0-1 mADC 256-TFSU-QQFB-C6-E21 Ph, 2 Wire 120V/5A 0-1-0 1-0-1 mADC 256-TFCU-QQFB-C6-E31 Ph, 2 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-TFAU-QQFB-C6-E43 Ph, 3 or 4 Wire 120V/5A 0.5-1-0.5 1-0-1 mADC 256-TFTU-QQFB-C6-E23 Ph, 3 or 4 Wire 120V/5A 0-1-0 1-0-1 mADC 256-TFEU-QQFB-C6-E33 Ph, 3 or 4 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-TFBU-QQFB-C6-E4Power Factor (Suits Digital Meters)1 Ph, 2 Wire 120V/5A 0.5-1-0.5 0.5-0-0.5 mADC 256-TDSU-QQM3-C6-E21 Ph, 2 Wire 120V/5A 0-1-0 1-0-1 mADC 256-TDCU-QQM1-C6-E31 Ph, 2 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-TDAU-QQM2-C6-E43 Ph, 3 or 4 Wire 120V/5A 0.5-1-0.5 0.5-0-0.5 mADC 256-TDTU-QQM3-C6-E23 Ph, 3 or 4 Wire 120V/5A 0-1-0 1-0-1 mADC 256-TDEU-QQM1-C6-E33 Ph, 3 or 4 Wire 120V/5A 1-0-1-0-1 1-0-1 mADC 256-TDBU-QQM2-C6-E4Phase Angle1 Ph, 2 Wire 120V/5A 78/0/36 1-0-1 mADC 256-TPSU-QQFB-C6-Z21 Ph, 2 Wire 120V/5A 60/0/60 1-0-1 mADC 256-TPSU-QQFB-C6-Z13 Ph, 3 or 4 Wire 120V/5A 78/0/36 1-0-1 mADC 256-TPTU-QQFB-C6-Z23 Ph, 3 or 4 Wire 120V/5A 60/0/60 1-0-1 mADC 256-TPTU-QQFB-C6-Z1<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


Veris Split Core KW Transducers<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>• Meter electronics and current transformersin a single package• Split-core system eliminates the need toremove conductors• Automatic compensation for CT orientation• Continuous TRMS ReadingsSPECIFICATIONSInput Primary Voltage208-480VAC rms, 50/60HzNumber of Phases Monitored One or ThreeInternal Isolation2000VAC rmsInsulation Class600VAC rmsTemperature Range0 to 60°C, 50°C for 2400AHumidity Range0 to 95% non-condensingAccuracy ±1%Output4-20mASupply Power (current loop) 9-30VDC; 30mA max.CT OpeningSmall 1.5" x 1.25" (38x32mm)Medium 2.9" x 2.45" (73x62mm)Large 5.5" x 2.45" (140 x 62mm)Models with Modbus and Pulse Outputs also available.ORDERING INFORMATIONSingle CT Models for Use w/ Balanced 3Ø Loads or 1Ø 2 Wire InstallationsMax.Model Voltage Amps CT SizeVE/H8041-0100-2 208/240 100 smallVE/H8041-0300-2 208/240 300 smallVE/H8041-0400-3 208/240 400 mediumVE/H8041-0800-3 208/240 800 mediumVE/H8041-0800-4 208/240 800 largeVE/H8041-1600-4 208/240 1600 largeVE/H8041-2400-4 208/240 2400 largeVE/H8042-0100-2 480 100 smallVE/H8042-0300-2 480 300 smallVE/H8042-0400-3 480 400 mediumVE/H8042-0800-3 480 800 mediumVE/H8042-0800-4 480 800 largeVE/H8042-1600-4 480 1600 largeVE/H8042-2400-4 480 2400 largeThree CT Models for Use with Any 3Ø Load or 1Ø 3 Wire InstallationsMax.Model Voltage Amps CT SizeVE/H8043-0100-2 208 100 smallVE/H8043-0300-2 208 300 smallVE/H8043-0400-3 208 400 mediumVE/H8043-0800-3 208 800 mediumVE/H8043-0800-4 208 800 largeVE/H8043-4600-4 208 1600 largeVE/H8043-2400-4 208 2400 largeVE/H8044-0100-2 480 100 smallVE/H8044-0300-2 480 300 smallVE/H8044-0400-3 480 400 mediumVE/H8044-0800-3 480 800 mediumVE/H8044-0800-4 480 800 largeVE/H8044-1600-4 480 1600 largeVE/H8044-2400-4 480 2400 largeVeris Current Switch & Relay• Independent switch & relay operation• Command & status in one device• Adjustable setpoint• Relay & switch status LEDs simplify setupNEWSPECIFICATIONSCurrent Range: 1-135ASensor Power: InducedInsulation Class: 600VAC rmsFrequency Range: 50/60Hz.Temperature Range: -15° to 60°CHumidity Range: 0-95% non-condensingSetpoint Adjustable: 1-135AHysteresis:10% TypicalDimensions: 2.95" x 2.68" x 1.04"Sensor Opening: 0.75" (19mm) Dia.H735 ▲ORDERING INFORMATIONModel Relay Contacts* Coil Solid State OutputVE/H735 Form A (SPST) 5(3)A@250VAC, 30VDC, 1/6HP 24VAC/DC 10mA 0.1A@30VAC/DC N.O.VE/H738 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 24VAC/DC 10mA 1.0A@30VAC/DC N.O.VE/H739 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 24VAC/DC 10mA 0.2A@120VAC/DC N.O.VE/H748 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP 24VAC/DC 10mA 1.0A@30VAC/DC N.O.VE/H749 Form C (SPDT) 8(3.5)A@250VAC, 30VDC, 1/4HP 24VAC/DC 10mA 0.2A@120VAC/DC N.O.VE/H758 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 9-12VDC 10mA 1.0A@30VAC/DC N.O.VE/H759 Form A (SPST) 10(5)A@250VAC, 30VDC, 1/3HP 9-12VDC 10mA 0.2A@120VAC/DC N.O.* Resistive load (inductive load).Also available in split core style (H930 series)98<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com


<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>Newport Load CellsMiniature Compression Load CellORDERING INFORMATIONCapacity (lb.) Model Number0-25 LCGD-250-50 LCGD-500-100 LCGD-1000-250 LCGD-2500-500 LCGD-5000-1000 LCGD-1K0-2000 LCGD-2K0-5000 LCGD-5K0-10,000 LCGD-10K0-50,000 LCGD-50KSPECIFICATIONSExcitation: 10 VAC/ DCOutput:2 mV/ V nominalAccuracy Class: 0.25%Material:Stainless SteelLinearity: ±0.25% FSOHysteresis: ±0.20% FSORepeatability: ±0.10% FSOSafe Overload: 150% FSOLCGD-500▲▲ LCGD-50Cantilever Beams• Tension/Compression• Load Button, Rod End and Base Plate Mounting Accessories▲Model LC501SPECIFICATIONSOutput:3 mV/ V ±0.0075 mV/ VExcitation:10 VDC (15 VDC max)Accuracy:0.03% FSOCalibrated Air: 0%, 50%, 100%, 50%, 0%Linearity:0.03% FSOHysteresis: 0.02% FSORepeatability: 0.02% FSOZero Balance: ±1% FSOSafe Overload: 150% FSOMaterial:Stainless SteelORDERING INFORMATIONAccessories for LC501 SeriesCapacity Model Load Button Rod End Base Plate(lb.) Number Model Model Model±100 LC501-100 LBC-012 REC-012M BP-10±200 LC501-200 LBC-012 REC-012M BP-10±500 LC501-500 LBC-012 REC-012M BP-10±1000 LC501-1K LBC-012 REC-012M BP-15±2000 LC501-2K LBC-012 REC-012M BP-15±5000 LC501-5K LBC-012 REC-012M BP-15±10,000 LC501-10K LBC-034 REC-034M BP-20Low Profile Load CellsORDERING INFORMATIONTension/CompressionCompressionCapacity Cable Style Connector Style(lb.) Model No. Model No.0-50 LC401-50 LC411-500-100 LC401-100 LC411-1000-250 LC401-250 LC411-2500-500 LC401-500 LC411-5000-1000 LC401-1K LC411-1K0-3000 LC401-3K LC411-3K0-5000 LC401-5K LC411-5K0-10,000 LC401-10K LC411-10K0-20,000 LC401-20K LC411-20K0-50,000 LC401-50K LC411-50KCapacity Model No.±50 LCHD-50±100 LCHD-100±500 LCHD-500±1K LCHD-500±3K LCHD-3K±5K LCHD-5K±10K LCHD-10K±20K LCHD-20K±30K LCHD-30K±50K LCHD-50K▲Model LC411SPECIFICATIONSOutput (FSO): 3 mV/ V ±0.25%CompressionTension/CompressionExcitation:10 VDC (15 VDC max)Linearity: ≥3000 lb: 0.10% FSO 0.10% FSO


<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong>Hioki Chart Recorders2 or 4 Channel Memory RecorderHigh-speed electronic recorders with powerful trigger functions.Use for low-speed/long-term continuous recording or capturinghigh-speed transients.8807▲ORDERING INFORMATIONHI/8807-01 2 Channel Memory RecorderHI/8808-01 4 Channel Memory RecorderHI/8922Detachable Printer (requires AC adapter)HI/9197Analog Input Leads (1 channel, 1.5m, alligator clips)HI/9018-10 Clamp-on Probe 10-500A, 40Hz-3kHzHI/9418-10 100-240V AC Adapter (50/60 Hz) for 8807/8HI/9447Rechargeable Battery (3 hour use)HI/9391Carrying CaseHI/9612RS-2332 Cable (1.5m)4 or 8 Channel Memory Recorder• 4/8 analog+ 16 logic inputs• 6.4-inch colorTFT liquid crystal display• 4M word memory• Built-in printeruses 110mmpaper• RS-232,LAN & GPIB interfaces8835▲SPECIFICATIONSInput: 2 analog, isolated + 8 logic (8807-01)4 analog, isolated + 8 logic (8808-01)Range:10 mV to 100 V/division, 13 ranges (10 division f.s.)Max. Voltage: 450V differential, 450V common modeAccuracy, BW: ±0.5%, DC to 50 kHz ± 3 dBInput:1MΩ, isolated BNC conncetorTrigger Source: Analog in, logic in, A-B, external, timer, manual,logical AND/ORAnalog Trigger: Level, window, voltage drop, RMS level, waveformFunctionsMemory recorder, recorder, RMS & memory recorder(DC & 50/60 Hz only)Memory Time Axis: 200 µs to 5 minutes/division, 19 settings(1 division =80 samples)Memory Capacity: 256 k words/ch (using CH1) 128 k words/ch(using CH1 & CH2)Data storage: Type II PC card slot (for SRAM cards to 32 MB,flash ATA cards to 528 MB)Interfaces:RS-232C, PC card fax modemDisplay:5.7-inch STN color LCDPrinter Option: 112 mm (4.4 in) x 18 m (59.06 ft), thermal paper rollOther functions: DMM function (numeric display), Scaling,Parameter calculations, Cursor readout, etc.Power:AA batteries, AC adapter, rechargeable batteryDimensions: 8.0" x 6.7" x 2.1" (203x170x52mm)Supplied with AA batteries, shoulder belt & Waveform viewer softwareHigh Speed Memory Recorder• Up to 20M samples/second• Expandable to 64 channels• Large internal memory• 10.4-inch high resolutioncolor TFT display8860▲NEW117SPECIFICATIONSMeasurement Range: 10 mV to 50 V/div., 12 ranges (10 div. f.s.)with 8936 Analog InputFrequency:DC to 400 kHz ± 3 dB (with 8936 Analog Input)Memory Time Axis: 100 µs to 5 minutes/division, 20 settings(1 division =100 samples); external sampling(500 kS/s, minimum sampling period 2 µs)MeasurementMemory recorder, Recorder,Functions:RMS recorder (50/60 Hz or DC only)Memory Capacity 4 M words x 1 channel to 500 k words x 8 channelsData Storage:FD drive, Type III PC card slot (SRAM/flash ATA/harddisk card)Other Functions: FFT, waveform parameter calculations,memory segmentation, cursor readouts, etcPower:100-120 V AC (50/60 Hz), 10-28 V DCusing the 9439 DC Power AdapterDimensions:11.2" x 8.7" x 5.2" (285x220x132mm)Supplied with Power cord, Recording paper(1 roll), Dust cover, Roll paperattachment(2), PC card protector, Wave viewer software.Order input modules (voltage, temperature, FFT, strain, F/V, charge),input leads, probes, data storage & interface separately.SPECIFICATIONSMeasurement Range: 5 mV to 20 V/division, 12 ranges (20 divisions f.s.)Input Options:2ch, 12-bit, 20MS/s; 2ch, 16-bit, 2MS/s;1ch Voltage/RMS, 12-bit, 1MS/s; 16ch Voltage/TCTrigger Types:Level, window, period, glitch, slope, logic pattern,voltage drop, externalMemory Time Axis: 5ms to 5min/div, 25 settings or external samplingMemory Resolution: 100 points/div; zoom X2, X10Memory Capacity: 32M word, expandable to 1G wordData Storage:FD drive, MO drive, HDD drive, Type II PC card slot(flash ATA)External Interfaces: USB1.1, Ethernet 10/100T, GPIB, HTTP, FTP,SVGA monitorOther Functions: FFT, waveform comparison, waveform calculations,clock, memory backup, sync outPower:100-240 VAC, 140VA (300VA with A4printer option)Dimensions:13.0" x 10.75" x 7.25" (330x273x185mm)Specify up to four input modules, memory, data storage, interface & printeroptions. Test Leads and Carrying Case available separately.<strong>WESCHLER</strong> <strong>INSTRUMENTS</strong> • www.weschler.com • 800-903-9870 • fax: 800-903-9590 • info@weschler.com