Schiavello Interpower SoftwiringAdvantagesPowerAustralian MadeInterpowercomponents are madein Australia.Schiavello's Interpower electricalsoftwiring system delivers power andlighting to office workstations andbase-building installations, and offerssubstantial advantages over traditionalhardwiring.Interpower softwiring advantagesinclude:Faster installation installation canbe made in a fraction of the time ofhardwiring.Safer all components are factory testedand easy to install.Reusable there is no waste when usingInterpower softwiring as all Interpowercomponents are reusable. The systemis easily connected, disconnected orrelocated without the need to isolatepower and with minimal inconvenienceas opposed to an electrical hardwiredinstallation. All connections within theInterpower system are protected by apositive lock mechanism to preventaccidental power disconnection.Economical the initial cost of supplyand installation is normally moreeconomical than the equivalenthardwired system.product code: PM2VLDouble GPO Module Vertical EarthA 10 amp double GPO vertical earth module with built-indouble pole automatic switching designed to cascade tocarry 20 amp power. (Optional 32 amp power available).Available in right or left entry. Right entry shown.product code: PM2HDouble GPO Module Horizontal EarthA 10 amp double GPO horizontal earth module with built-indouble pole automatic switching designed to cascade tocarry 20 amp power. (Optional 32 amp power available).product code: PM2H1VLTriple GPO Module – 2 Horizontal, 1 Vertical EarthA 10 amp triple GPO, 2 horizontal, 1 vertical earth modulewith built-in double pole automatic switch designed tocascade to carry 20 amp power. (Optional 32 amp power available).Available in right or left entry. Right entry shown.1product code: PM4VLQuadruple GPO Module Vertical EarthA 10 amp quadruple GPO vertical earth module with built-indouble pole automatic switch designed to cascade to carry20 amp power. (Optional 32 amp power available).


Interpower 20 Amp Softwiring SystemSpecificationsDataThe Softwiring System shallbe Interpower asmanufactured by Schiavelloor similar. The System shallbe provided with aswitchboard fitted withmultiple starter sockets –20 amp circuit breakers andmains switch. Each starterrepresenting a power orlighting circuit shall befitted ready to accept thesoftwired lead.The system shall provide20 amp pin and contact andall internal wiring shall havea minimum cross sectionalarea of 2.5 mm sq (complyingwith AS/NZS 61535).Each connection in thesystem shall be protected bya positive mechanical lock clipto retain constant contact andshall not disengage withoutthe use of a tool to releasethe clip.The system shall providea double 10 amp GeneralPurpose Outlet (GPO) inmodules of 2, 3, or 4, withbuilt-in automatic doublepole switching. Each GPOmodule shall plug into eachother without the need ofhaving a lead with plug andsocket between the two GPOmodules. Each GPO shall beavailable with a horizontalor vertical socket outlet.Each GPO shall be availablewith a 10 amp circuit breaker(optional).A Residual Current Device (RCD) modulecan be fitted to every circuit after the startersocket and before the first power outlet, tobe placed in a visible position.A surge protection module shall be availableas required.All starters, plugs and sockets, GPOs, RCDs,surge protectors and junction boxes shall beencased in a flame retardant polycarbonateor similar housing, permanently welded.The system shall cascade with a 20 ampextension lead available in various lengths,fitted with a plug and socket.All components shall be factory tested andshall carry a test approval label printed withthe date of the test.Installation: Each network of power modulesmust be connected to a dedicated 20 ampcircuit. Each sub-circuit is to be protectedby an appropriately rated circuit breaker.Connection to the sub-circuit shall be madevia an Interpower 20 amp starter socket.The system shall be tested and certified toAS/NZS 3131 and manufactured to AS 9001.The system must also be installed by aqualified and licensed electrician inaccordance with relevant Australian and NewZealand Standards.product code: NGDM/2Data Module – 2The data module is used to house the RJ45 voice and data outletswithin the workstation system. There are numerous voice and dataoutlets within the communication network that require differentcut-out sizes for housing. The data modules are moulded with thevarious common housing dimensions, and irregular sizes can becut out as requested.NB: Able to take 1, 2 or 3 cutouts (depending on size). Coloursavailable in Grey, White, Red, or Black.product code: NGDM/4Data Module – 4Information as above “Data Module – 2”.NB: Able to take 1, 2, 3 or 4 cutouts (depending on size).Colours available in Grey, White, Red, or Black.product code: NGDM/6Data Module – 6Information as above “Data Module – 2”.NB: Able to take 1, 2, 3, 4, 5 or 6 cutouts (depending on size).Colours available in Grey, White, Red, or Black.3


Standard Service Railproduct code: SR/3P/4Dproduct code: SR/4P/RCD/4Dproduct code: SR/4P/4Dproduct code: SR/2x2P-2C/4Dproduct code: SR/3P/RCD/4Dproduct code: SR/2x2P-2C/2XRCD/4DData Cutouts available in Quad, Triple, Dual and Single 25 mm Square(4D, 3D, 2D & 1D).Power Cable Entry on Extreme Left, Data Cable Entry on Extreme Right,Data Cables can enter through back of module for Long/Deep RearEntry Data Jacks upon request.4


Lighting + Softwiring ApplicationsThe Interpower softwiring system is easily adapted to suit a vast majority of lightinginstallations. Simply lay the light fittings in place and connect via pre-installed leadsand junction boxes. The installation time is vastly reduced, minimising installation timeon site and therefore saving costs in on-site labour. Changes after initial installationcan be made in a significantly reduced time frame, and with all Interpower componentsbeing reusable, waste is eliminated, and mess and down-time is substantially reduced.Refer to page 6 for installation details.product code: LT- 236PL-I002Softwired Ceiling LightThe Interpower softwiring lighting system can easily accommodate anytype of light fitting. The light fitting requires two leads of appropriatelength fitted with a plug and socket.product code: LTEXI-IOO1Exit LightMaintained illuminated exit sign with softwired interconnection lead.Active supply inTo light fittingActive supply outOne Way Switch BoxSwitch Wireproduct code: JB-IWOne-Way Switch JunctionActive in - Active out. Switch outlet and light bank outlet.product code: PMW1Softwired Light SwitchAvailable in 1, 2, 3 and 4 gangs and other configurations upon request.Dimmer switch also available.Active supply inSwitch Wire twoTo light fittingsTwo Way Switch BoxSwitch Wire oneproduct code: JB-2WTwo-Way Switch JunctionActive in - Light Bank out.Two-way switch outlets.5Schiavello Interpower SwitchboardThe switchboard comes fully wired and ready to connect to mains power.The switchboard is available in the following sizes:Height Width No Circuit500 x 450 18600 x 450 24750 x 450 30Larger sizes are built to suit various applications.


High Density Cascaded LightingAustralian MadeInterpowercomponents are madein Australia.Commercial lighting installations canbe very efficiently wired with Interpower.The light fixtures can be pre-wired withrelatively short plug and socket leads.Extension leads are used tointerconnect the fixtures over longerdistances. This method of installationis very rapid and flexible.For more information call your localSchiavello distributor.ONE WAY SWITCH JUNCTIONEXIT LIGHTJUNCTION BOXPOWER FROMSWITCH BOARDPLUG & SOCKETSWITCHSOFTWIRING CEILING LIGHTEXIT LIGHTTO NEXT LIGHTING BANK6


Melbourne Head OfficeSchiavello (Vic) Pty Ltd1 Sharps RoadTullamarine MelbourneVIC Australia 3043T: 61) 3 9330 8888F: 61) 3 9330 8899Melbourne ShowroomSchiavello (Vic) Pty Ltd31-49 Queensbridge StreetSouthbank MelbourneVIC Australia 3006T: 61) 3 9674 1500F: 61) 3 9674 1650AdelaideSchiavello (SA) Pty LtdGround Floor, 101 Currie StreetAdelaide SA Australia 5000T: 08) 8112 2300F: 08) 8231 1419BrisbaneSchiavello (Qld) Pty Ltd265 Coronation DriveMilton BrisbaneQLD Australia 4064T: 07) 3368 3388F: 07) 3368 2125CanberraSchiavello (ACT) Pty Ltd2-6 Collie StreetFyshwick CanberraACT Australia 2609T: 02) 6124 0500F: 02) 6280 4370DarwinSchiavello (NT)A division of Schiavello (Vic) Pty LtdOffice 1, Unit 5, 356 Bagot RoadMillner Darwin NT Australia 0810T: 08) 8948 1922F: 08) 8948 1622PerthSchiavello (WA) Pty Ltd1315 Hay Street West PerthWA Australia 6005T: 08) 9322 6555F: 08) 9322 1337SydneySchiavello (NSW) Pty Ltd69 Campbell StreetSurry Hills SydneyNSW Australia 2010T: 02) 9211 3311F: 02) 9212 3788JapanSchiavello Japan LimitedToranomon Marine Building 1F,3-18-19, Toranomon Minato-KuTokyo 105-0001, JapanT: 81) 3-5402 7541F: 81) 3-5402 7542Middle EastSchiavello Project SolutionsThe Fairmont: Office Suite 514Sheikh Zayed Road, DubaiUnited Arab EmiratesT: 971 4 3291666F: 971 4 3290906SingaporeSchiavello Singapore Pte LtdNo.1 Magazine Road#01-05 Central MallSingapore 059567T: 65) 6 533 8011F: 65) 6 533 2811www.schiavello.comSCH/W05-C