05.09.2015 Views

Marley Eclipse half-round PVC downpipe

102367_Elcipse generic fly 07.indd - Marley New Zealand

102367_Elcipse generic fly 07.indd - Marley New Zealand

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Marley</strong> <strong>Eclipse</strong> <strong>half</strong>-<strong>round</strong> <strong>PVC</strong> <strong>downpipe</strong><br />

- where design meets form & function.<br />

Rainwater Solutions


Where Design Meets Form & Function<br />

The <strong>Eclipse</strong> Downpipe is designed to enhance the aesthetics of a building’s design without compromising on functionality. The <strong>Eclipse</strong> system<br />

includes external and internal bends as well as <strong>round</strong> <strong>Eclipse</strong> outlets and stormwater adaptors. These fittings are all compact and unobtrusive<br />

fi<br />

adding to the slimline look.<br />

The shape of <strong>Eclipse</strong> also makes<br />

it easy to paint, offering the<br />

option of using the <strong>downpipe</strong><br />

as a feature in a building’s<br />

design or alternatively making the<br />

<strong>downpipe</strong> even more inconspicuous.<br />

The shape and clipping system<br />

allows <strong>Eclipse</strong> to work with<br />

different claddings from<br />

traditional brick or weatherboard<br />

to contemporary zincalume ® .<br />

The slim <strong>PVC</strong> <strong>half</strong>-<strong>round</strong> <strong>downpipe</strong> sits flush against the wall and features<br />

a concealed clipping system.<br />

Performance<br />

The <strong>Eclipse</strong> Downpipe is designed to perform on a Maximum Roof Area per<br />

Downpipe of 72m 2 . To calculate your <strong>Eclipse</strong> Downpipes requirement, the<br />

following factors need to be considered.<br />

- the roof pitch<br />

- the house plan area<br />

Installation<br />

Installation instructions are available on <strong>Marley</strong> website: www.marley.co.nz.<br />

NB: <strong>Eclipse</strong> is not suitable for installation in a concealed cavity situation<br />

(eg: inside a wall) or in a wet syphon system.<br />

Roof Pitch House Plan Area per Downpipe (m 2 )<br />

10º 66<br />

20º 61<br />

30º 56<br />

40º 51<br />

50º 45<br />

60º 39<br />

*Based on an Average Rainfall Intensity of 150mm per hour. The plan area calculation is based<br />

on the slope factor described d in table 3.2, in the Standard d AS/NZS 3500.3:2003.<br />

PRODUCT COMPONENT CODE PRODUCT COMPONENT CODE PROFILE<br />

<strong>Eclipse</strong> Downpipe<br />

HR80<br />

Outside 95 Bend<br />

HR.80.95OB<br />

Top Transitional<br />

Adapter<br />

Downpipe Joiner<br />

HR.80.TA<br />

HR.80.J<br />

Inside 95 Bend<br />

Bottom Transitional<br />

Adapter<br />

HR.80.95IB<br />

HR.80.BA<br />

123mm<br />

54mm<br />

85 Flat Bend HR.80.85FB<br />

Fixing Clip<br />

HR.80.C<br />

DISCLAIMER<br />

This technical brochure has been compiled by <strong>Marley</strong> New Zealand Limited (“The Company”) to promote better understanding of the technical<br />

aspects of the Company’s products to assist users in obtaining from them the best possible performance.<br />

The technical brochure is supplied subject to acknowledgement of the following conditions:<br />

The technical brochure is protected by Copyright and may not be copied or reproduced in any form or by any means in whole or in part<br />

without prior consent in writing by the Company. Product specifications, usage data and advisory information may change from time to<br />

time with advances in research and field experience. The Company reserves the right to make such changes at any time without notice.<br />

Correct usage of the Company’s products involve engineering judgements which cannot be properly made without full knowledge of all the<br />

conditions pertaining to each specific installation. The Company expressly disclaims all and any liability to any person whether supplied with<br />

this publication or not in respect of anything and of the consequences of anything done or omitted to be done by any such person in reliance<br />

whether whole or partial upon the whole or any part of the contents of this publication. No offer to trade, nor any conditions of trading, are<br />

expressed or implied by the issue or content of this manual. Nothing herein shall override the Company’s Condition of Sale, which may be<br />

obtained from the Registered Office fi or any Sales Offifi<br />

ce of the Company. This technical brochure is and shall remain the property of the<br />

Company, and shall be surrendered on demand to the Company.<br />

AUCKLAND<br />

Mahia Road, Manurewa, Private Bag 802 Manurewa<br />

Sales Department: Telephone 09 279 2777<br />

Direct Fax 09 279 2778 Freefax 0800 652 621<br />

Head Office: fi Telephone 09 279 2799 Fax 09 279 2798<br />

Contact Centre: 0800 222 922<br />

CHRISTCHURCH<br />

Shands Road, Hornby, PO Box 16233 Christchurch<br />

Contact Centre: 0800 222 922<br />

102367<br />

For further information: 0800 MARLEY (0800 627 539) www.marley.co.nz<br />

Rainwater Solutions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!