Home

fineco.lt
  • No tags were found...

MICON - Fineco.lt

Micon

Measure and control instruments

MICON

is a company with over 18 year of experience

about design and manufacturing of instruments

to measure and control water treatment parameters.

MICON

has developed this experience thanks to the collaboration

side by side with our client, which are experts in specific fields

as swimming pools manufacturers, industries, dosing systems ...

Home

MICON

follows a complete internal production cycle,

starting to circuits and software design,

electronic components mounting,

software and circuit test controls,

up to the final assembling and the delivery.

In this way we can check our products during

the entire production process, keeping a very good

relationship between quality and price


Micon

Measure and Control Instruments

Home

M20

Series

Multiparametric

Instruments

M05

Series

Probes and

Accessories

Metering

Dosing

Pumps

M96+

Series

Dosing Systems

(Swimming pools)


M20

controller

Home

Instruments M20 series are based on microproce ssor technology, to measure and

control in water treat ment and chemical pro cess applications . T ypical a pplications are:

drinkable water, cooling towers, waste wate r treatment, swimming pools, industry,

agriculture, and so on.

Thanks to the wide range of bow type this series is very suitable for all applications type.

- Backlight LCD display

- Available versions:

• Rack for electric panel

• DIN rail

• Wall mounting with IP65 box

- 2 Set-point free contact relay output, On-Off or proportional time/pause mode (PWM)

- 4-20 mA proportional output with galvanic separation, selectable on Set-point2 (dosing

pumps) or on measure range (recorder)

- Adjustable delay time and Hysteresys

MICON

measure technology

Measure and control instruments for water treatment


M20

controller

Home

modelli M20-PH M20-MV M20-CL M20-CD M20-TEMP M20DIN-TP

0-10.00 µS K=5

Measure range

0-14.00 pH 0-1000 mV 0-10.00 ppm 0-100.0 µS K=5 0-100 °C

0-1000 µS K=5

0-10.000 µS K=1

Functions

Redox potential Free Chlorine Conductivity Temperature External pulse

pH measure and

(ORP) measure measure and measure and measure and multiplier/

control

and control

control

control

control

divider

Resolution ± 0.01 ph ±1 mV ±0.01 ppm ± 1% F.S. ± 0.1 °C

Display

LCD 3 ½ digit backlight

Accuracy

± 1% E.S.

Controls

Keypad 5 Keys

Temperature

compensation

Manual temperature compensation 0-100 °C

Set-point

2 free-contact relay ON/OFF load 5A 230vac

Output

Analogical 4-20mA selectable for recorder or proportional to the set-point 2 with galvanic separation

Hysteresys

Set- point hysteresys adjustable

Delay

Set-point delay time adjustable

PWM

set point 2 selectable in proportional time/pause output

Power supply

230 Vac 50Hz (optional 110/ 24 Vac)

Consumption

5W

Box

DIN 6 modules / RACK 96X96 / IP65 plastic box

Dimensions

106 x90x58 mm (DIN) / 96X96X100 mm (Rack) / 115x180x75 mm (box)

Weight

310 gr. (DIN) / 560 gr. (Rack) / 550 gr. (box)

serie D serie R Serie W

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


M96

controller

Home

M96+ ins trument s eries arra nge the innovati ve MICON display, with a wide area

dedicated to the measure and a n alphanumeric line to simplify t he instrument managing

during the setting a nd working. With the microprocessor techno logy that’s an instrument

series adaptable to the main application in water treatment and industry.

- 3 set-point with on/off free contact relays:

> Hystresis and relay delay time adjustable

> Minimum and maximum level measure alarm

> PWM (pulse with modulation) control relay, to manage the relay via proportional

time/pause working way

> “Timeout” alarm, if the dosing period it’s longer then the selected time the

Instrument shows an alarm situation

> 4-20 mA proportional output (only for set-point 1) with galvanic separation

- 4-20 mA output on the measure range with galvanic separation

- Flow sensor input

- Automatic or manual temperature compensation (pH, CL, conductivity)

- Backlight MICON display

- Password to freeze the setting

- Start-up delay time adjustable

- Relay probes maintenance

- “Down” arrow key to show the instrument setting sequence

MICON

measure technology

Measure and control instruments for water treatment


FUSE

M96

controller

Home

modelli M96+ PH M96+ MV M96+ CL M96+ CD M96+ TB

Measure range 0-14.00 pH 0-1999 mV 0-10.00 ppm

0-19.99 µS K=5

0-199.9 µS K=5

0-1999µS K=5

0 – 40 NTU

0-19.99 mS K=1

Function

Measure, control and Measure, control and Measure, control and

Measure, control and

Measure of the

regulation of the regulation of the regulation of the

regulation of the pH

turbidity

Redox (ORP)

Chlorine

conductivity

Resolution ± 0.01 ph ±1 mV ±0.01 ppm ± 1% F.S. ± 0.1 NTU

Display

MICON retroilluminato LCD più linea 12 caratteri

Accuracy

± 1% F.S.

Controls

Keypad 6 keys

Temperature

compensation

Automatic or manual with temperature range 0-100 °C

Set-point

3 ON/OFF relays, max charge 5A to 230vac

Current output

Proportional to the set-point 1 (*) and on the measure range (recorder)

Hysteresis

Adjustable for all set points

Delay time

Adjustable for all set points

P.W.M.

Selectable and adjustable for all set points

Power supply

100...230 Vac 50Hz

Consumption

5W

Box

In ABS V0 IP65 protection degree (W series) / black anodized aluminium (R series)

Dimensions

202x201x106 mm (W series) / 72x144x134 mm (R series)

Weight

1220 gr. (W series) / 850 gr. (R series)

(*)Not available on M96+ TB model

W series

R series

201.0

184.0

66 mm

72 mm

9 mm

115 mm

134 mm

136 mm

144 mm

184.0

202.0

106.0

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


M05 controller

Home

High performance instruments se ries, wall mounti ng box, micr oprocessor technology based to

measure and control in water treatment and chemical process applications. The wide graphic display

simultaneously shows the parameters. It’s a versatile and convenient instrument series, thanks to the

RS232 connection, via GSM connection.

- Back-light graphic display

- Multi-power supply: 100..240 Vac

- Hysteresys and delay time adjustable for each set-point

- 1 Alarm point for each set-point

- Over time dosing alarm

- 1 Output relay for maintenance (probes cleaning)

- 1 Alarm relay

- RS232 connection with galvanic separation for remote control (Micon software)

- GSM modem connection (optional)

- Flow sensor input

- Level probe input

- Temperature compensation and visualization

Single Measure (+temperature)

- Two set-points with free contact relays, selectable On-Off mode or proportional time/pause

(PWM)

- One 4-20mA proportional output signal with selectable range and galvanic separation.

- One frequency output signal with selectable range

Double Measure (+temperature)

- Three set-points (2 for the pH and 1 for the other measure) with free contact relays,

selectable On-Off mode or proportional time/pause (PWM)

- Two 4-20mA proportional output signal (1 for each measure) with selectable range and

galvanic separation.

- Two frequency output signal (1 for each measure) with selectable range

MICON

measure technology

Measure and control instruments for water treatment


M05

controller

Home

Models pH mV CL CD PH/RX/°C PH/CL/°C PH/CD/°C

Measure range 0-14.00 pH 0-1999 mV 0-10.00 ppm

0-14.00 pH

0-14.00 pH

0-14.00 pH

0-1999 µS

0-1999 mV 0-10.00 ppm 0-1999 µS K=1

(K=1)

0-100°C

0-100°C

0-100°C

Resolution ± 0.01 ph ±1 mV ±0.01ppm ±1 µS

±0.01 ph/±1 mV ±0.01 pH/±0.01 ppm ±0.01 ph/±1 µS

±0.1°C

±0.1°C

±0.1°C

Current output

1 proportional 4-20mA with selectable range - 400 Ω 2 proportional 4-20mA with selectable range - 400 Ω max - with

max - with galvanic separation

galvanic separation

Frequency output 1 selectable with galvanic separation 2 selectable with galvanic separation

Set-point

2 output free contact relays (5 A max) 3 output (2 for the pH and 1 for the other measure) free

contact relays (5 A max)

Level probe 1 level probe input 2 level probe input

Probe cleaning Not available Timed relay output

Display

Backlight graphic display 128x64

Accuracy

± 1% E.S.

Controls

Keypad 7 Keys

Temperature Manual or automatic temperature compensation 0-100 °C

Hysteresys

Adjustable for each set point

Delay

Adjustable for each set point

P.W.M.

Time/pause proportioning mode for each set point

Alarm

Alarm point for each set point (1 relay available)

RS 232

RS232 connection with galvanic separation for remote control (Micon software)

Modem

(optional)

Allowed to GSM modem connection

Flow sensor

Output relay freezing via flow sensor control

Datalogger

(optional)

Through computer link

Power supply

100...240 Vac

Box

In ABV V0 with IP65 protection degree

Dimensions

202 x 184 x 106 mm

Weight

1.150 gr.

201.0

184.0

184.0

202.0

106.0

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


M20D+

multiparametric controller

Home

Instruments M20D+ series u nites to a very g ood meas ure showing also an

alphanumeric line that simplify the disp lay read ing du ring th e measu re ( alarm,

temperature and set visualizations) and als o during the calibration and ins trument set.

The setting phil osophy follows the same work ing mode of a mobile phone , in this way

M20D+ is a product very easy to use for the end user.

- Backlight MICON display

- Power supply 90…230 Vac

- 2 Set-point with output relay On-Off free contact for each measure

- 4-20 mA proportional output with galvanic separation, selectable on the measure range

(recorder) or on the set-point 1 and 3; one for each measure

- Adjustable delay time for each set-point

- Proportional output time/pause mode (PWM) for each set-point

- Adjustable hysteresis for each set-point

- Min/Max alarm for each set-point

- Wall mounting box IP65 protection degree with separated terminal-board cover

- Key “arrow down” to show instrument settings

- Flow sensor input

MICON

measure technology

Measure and control instruments for water treatment


Home

M20D+

multiparametric controller

Models M20D+ PH-MV M20D+ PH-CL

Measure range

0-14.00 pH

0-14.00 pH

0-1000 mV

0-10.00 ppm

Functions Measure, control and regulation of pH and Redox (mV) Measure, control and regulation of pH and Chlorine

Resolution ± 0.01 ph ±1 mV ± 0.01 ph ±0.01 ppm

Display

Backlight MICON

Accuracy

± 1% F.S.

Controls

keypad 6 keys

Temperature

compensation

Manual or automatic temperature compensation 0-100 °C

Set-point

2 points ON/OFF load 5A to 230vac for each measure

Output

proportional 4-20mA with galvanic separation, selectable on set-point 1 and 3 or on the measure range

one for each measure

Hysteresys

Adjustable for each set-point

Delay

Adjustable for each set-point

P.W.M.

Selectable for all relays (proportional time/pause mode)

Alarm

Min/Max for each set-point

Power supply

90…230 Vac 50Hz

Consumption

5W

Box

In ABV V0, IP65 protection degree. Separated terminal-board cover

Dimensions

202 x 184 x 106 mm

Weight

1150 gr.

201.0

184.0

184.0

202.0

106.0

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


MLP

multiparametric controller

Home

Instruments MLP seri es, wall mounting box, are based on micropro cessor technology to

measure and control in water treatment and chemic al process applications. It’s a versatile and

convenient instrument series, thanks to th e si multaneous p arameter visualizat ion and the

connection via RS232.

- Alphanumeric 2x16 backlight display.

- 4-20 mA proportional output on set-point, 1 for each measure with galvanic separation

- 4-20 mA proportional output on measure range, 1 for each meas ure with galvanic separation

- Adjustable Hysteresys for each set-point

- Adjustable delay time for each set-point

- Alarm relay

- Alarm min/max type (alarm window) 1 for each set-point

- Output relay for maintenance (probes cleaning)

- RS232 connection with galvanic separation for remote control (Micon software)

- Temperature compensation and visualization

- Simultaneous parameters visualization.

- MLP-2 Series

- Version available pH-Rx, pH-Cl and pH-CD

- 3 set-point with free contact output relay, On-Off or proportional time/pause mode

- MLP-3 Series

- Version available pH-Rx-Cl

- 5 set-point with free contact output relay, On-Off or proportional time/pause mode

MICON

measure technology

Measure and control instruments for water treatment


Home

MLP

multiparametric controller

Models

MLP2

MLP2

MLP2

MLP3

PH/RX/°C

PH/CL/°C

PH/CD/°C

PH/RX/CL/°C

Measure range

0-14.00 pH

0-14.00 pH

0-14.00 pH

0-14.00 pH

0-1999 mV

0-1999 mV

0-10.00 ppm

0-19999 µS (K=1)

0-10.00 ppm

0-100°C

0-100°C

0-100°C

0-100°C

Resolution

± 0.01 ph / ±1 mV ± 0.01 pH / ±0.01ppm ± 0.01 ph / ±1 µS ± 0.01 ph / ±1 mV / ±0.01ppm

±0.1°C

±0.1°C

±0.1°C

±0.1°C

Display

alphanumeric 2x16 backlight LCD

Precisione

± 1% E.S.

Controlli

Keypad 7 Keys

Temperatura Manual or automatic temperature compensation 0-100 °C

Set-point

MLP2: 3 free contact output relay 5 A max 220VCA

MLP3: 5 free contact output relay 5 A max 220VCA

Current output

2 ( 3 x MLP3) proportional on a set-point 4-20mA 400 Ω max with galvanic separation

2 (3 x MLP3) proportional on the measure range (recorder) 4-20mA 400 Ω max with galvanic separation

Probes cleaning

Maintenance relay output

Delay

Adjustable for each set point

P.i.d.

Time/pause proportioning mode for each set point

Alarm

Alarm min/max (alarm window) for each set point

RS 232

RS232 connection with galvanic separation for remote control (Micon software)

Flow sensor

Output relay freezing via flow sensor control

Power supply

230 Vac 50/60 Hz (optional 110/ 24 Vac)

Box

ABS V0, IP65 protection degree

Dimensions

328 x 240 x 105 mm

Weight

1843 gr. (MLP2 series) / 1880 gr. (MLP3 series)

Dimensions

240.0

105.0 328.0

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

Via Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


Swimming Pool’s Systems

Home

MICON manufact uring a complete range of pa nel to measure and control chemical

water para meters into a swimm ing pool. Ou r systems are “r eady to use” and they are

complete of water filter, probe-holder, prob es and accessories. Following some example

of our standard types, of course our comp any manufactures also following the specific

client requests.

With instru ments MLP series. 2 measure

(ph-Chlorine (or R edox) + temperature) or 3

measure (pH-Chlorine-Redox + t emperature)

versions. Relay mod e On/Off or pr oportional

pause/time (PWM). N.2 4-20 mA output

signal for each measure, one proportional to

the set-point and one on the meas ure range

(recorder). RS232 connections for remote

control v ia PC ( MICON software). This

solution allows to tha t system t ype to cov er

also big installation.

Panels with instruments M20D+ series on

board are a very g ood compromise betw een

quality and price. 2 measure , pH -Chlorine or

pH-Redox (+ temp eratura). Man y outp ut

singal type available: On/Of f or pr oportional

pause/time (PWM) relays; 4-20 mA output

signal proportional to t he set -point value or

on t he me asure ra nge (r ecorder). A wi de

display d edicated t o sh ow th e mea sure and

an alphanumeric line al lows this product very

“easy t o us e”, during working a nd setting

mode.

MICON

measure technology

Measure and control instruments for water treatment


Home

Swimming Pool’s Systems

Metering pumps with instrument built-in (pH,

Redox or Chlorine) PM series are a solution

very practi cal and with a good level pri ce.

Constant or propor tional flow rate selec table

from th e user. On t he met ering dosing

pumps is available a 4 -20 mA out put signa l

on the measure range (recorder).

MICON manufa cture also panel without

dosing pump s o n bo ard. Thank s t o t he

several out put signal t ype the M05 allows

to con trol each metering pump type or

dosing accessories. R elay On/Off or with

signal (proporti onal pause/tim e), frequ ency

signal and 4 -20 mA sign al output completely

selectable. RS232, for remote control from

PC, or GSM/ SPRS connections. M05 arrange

also a timed relay t o control t he possible

periodical m aintenance, for example, d osing

allows concentrated acid by a peristaltic

pump (MICON accessory).

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


M20C

dosing system

Home

M20C dosing systems are designed to be the be st way between efficiency and “user friendly”.

The small box, the LC D display and the peristaltic pump made the M20C a product very simply

to use, during the installation and also during the maintenance.

General features

• LCD display

• Microprocessor technology

• Measure available: pH, free Chlorine, Redox (ORP), Conductivity

• Pump regulation proportional or On/Off

• delay time adjustable

• Hysteresys adjustable

• Flow sensor input to stop the pump and to

start the alarm

• Pump flow rate 2.2 l/h

M20C P1

Version available:

• pH or Redox

(same model)

• free Chlorine

• Conductivity

M20C P2

Version available:

• pH-Redox

• pH-Chlorine

• pH- Conductivity

MICON

measure technology

Measure and control instruments for water treatment


Home

M20C

dosing system

Models M20-PH M20-MV M20-CL M20-CD

Measure range 0-14.00 pH 0-1000 mV 0-10.00 ppm

0-10.00 µS K=5

0-100.0 µS K=5

0-1000 µS K=5

0-10.000 µS K=1

Functions

pH measure and control

Redox potential (ORP) Free Chlorine measure and Conductivity measure and

measure and control

control

control

Resolution ± 0.01 ph ±1 mV ±0.01 ppm ± 1% F.S.

M20C P2

M20C P1

Display n.2 LCD 3 ½ DIGIT LCD 3 ½ DIGIT

Accuracy

± 1% E.S.

Controls n.2 Keypad 5 Keys Keypad 5 Keys

Temperature

compensation

Manual temperature compensation 0-100 °C

Set-point

N.2 for each measure ON/OFF load 5A to 230vac

N.2 for ON/OFF load 5A to 230vac

Dosing pump connected on set-point 1

Dosing pump connected on set-point 1

Relay

Alarm or output on set-point 2 value

All measures

Alarm or output on set-point 2 value

Hysteresys

Set- point hysteresys adjustable

Delay

Set-point delay adjustable

P.i.d.

set point 1 selectable in proportional time/pause output

Power supply

230 Vac 50Hz (optional 110/ 24 Vac)

Consumption

5W

Pump flow rate

2.2 l/h

Dimensions 240 x 200 x 115 mm 114 x 180 x 100 mm

Weight 1270 gr 610 gr

M20C P2

Dimensions

M20C P1

ZERO

GAIN

07.28 436

pH

mV

SET CAL FUN

SET CA L

FUN

ZERO

7.08

pH

ZERO

GAIN

SET

CAL

FUN

M20C

220 mm

159 mm

250 mm 125 mm

118 mm 107 mm

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

Via Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


PM-K

metering dosing pumps

(constant flow rate)

Home

Metering dosing pumps PM – K series

Constant flow rate.

• Led power-on

• Led pulse solenoid

• Knob flow rate percentage adjustment

• Double range regulation

• Keys max frequency selection (100% or 20%)

• Start and Stop Keys

• Plastic box IP65 protection degree

MICON

measure technology

Measure and control instruments for water treatment


PM-K

metering dosing pumps

(constant flow rate)

Home

Model

Flow rate

max

(l/h)

Pressure

max

(bar)

Frequency

max

(imp/min)

ml/pulse

Max suction

high

(m)

Standard power

supply (*)

Weight

(kg)

PM 01-15 1 15 120 0,14 2.0 230 V – 50/60 Hz 2,3

PM 02-10 2 10 100 0,33 2.0 230 V – 50/60 Hz 2,3

PM 05-07 5 7 100 0,83 2.0 230 V – 50/60 Hz 2,3

PM 08-10 8 10 120 1,11 2.0 230 V – 50/60 Hz 2,9

PM 20-03 20 3 120 2,60 2.0 230 V – 50/60 Hz 2,9

(*) Other power supply contact the headquarters

Dimensions

Materials

Pump head: polypropylene

(on request: PVC, SS316, PTFE, PVDF)

Diaphgram: PTFE

Connections: polypropylene

Foot filter: polypropylene

Injection valve: polypropylene

Suction tube: PVC crystal

Delivery tube: polyethylene

Lip valves (standard): FPM

(on request: silicon, EPDM, NBR)

Ball valves (on request): Pyrex, Kalretz,

SS316

Seat: FPM

(on request: silicon, EPDM, PTFE, NBR)

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

Via Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


PM-MF

metering dosing pumps

(proportional flow rate)

Home

Metering dosing pumps PM – MF series

Proportional flow rate from an external signal.

- Without programming: it’s sufficient to active the function

- Proportional to a digital signal (water-meter pulse-sender):

• ppm mode – selected ppm quantity the pump automatically adjust the dosage

• 1:n mode (external pulse multiplication)

• n:1 mode (external pulse division)

- Proportional to an analogical signal 4-20 or 20-4 mA

- Constant flow rate mode

- Automatic regulation frequency dosing

- Automatic managing excessive external pulses

(If the pump receive pulses during the dosage, the microprocessor adjust the frequency

to closing the dosage)

- Level probe input

- Plastic box IP65 protection degree

MICON

measure technology

Measure and control instruments for water treatment


PM-MF

metering dosing pumps

(proportional flow rate)

Home

Model

Flow rate

max

(l/h)

Pressure

max

(bar)

Frequency

max

(imp/min)

ml/pulse

Max suction

high

(m)

Standard power

supply (*)

Weight

(kg)

PM 01-15 1 15 120 0,14 2.0 230 V – 50/60 Hz 2,3

PM 02-10 2 10 100 0,33 2.0 230 V – 50/60 Hz 2,3

PM 05-07 5 7 100 0,83 2.0 230 V – 50/60 Hz 2,3

PM 08-10 8 10 120 1,11 2.0 230 V – 50/60 Hz 2,9

PM 20-03 20 3 120 2,60 2.0 230 V – 50/60 Hz 2,9

(*) Other power supply contact the headquarters

Dimensions

Materials

Pump head: polypropylene

(on request: PVC, SS316, PTFE, PVDF)

Diaphgram: PTFE

Connections: polypropylene

Foot filter: polypropylene

Injection valve: polypropylene

Suction tube: PVC crystal

Delivery tube: polyethylene

Lip valves (standard): FPM

(on request: silicon, EPDM, NBR)

Ball valves (on request): Pyrex, Kalretz,

SS316

Seat: FPM

(on request: silicon, EPDM, PTFE, NBR)

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

Via Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


PM-PH, MV, CL, CD

metering dosing pumps

(with measure instrument built-in)

Metering dosing pumps PM series

With measure instrument built-in

Home

- Without programming: it’s sufficient to active the functions

- Proportional dosing to the set-point

- Constant flow rate mode

- Level probe input

- Plastic box IP65 protection degree

- pH measure and control:

• Measure range : 0 - 14,00 pH (resolution 0,01 pH)

• BNC input from pH probe

- Redox potential (ORP) measure and control:

• Measure range: 0 - 1000 mV (resolution 1 mV)

• BNC input from Redox probe

- Free Chlorine concentration measure and control:

• Measure range: 0- 10 ppm (resolution 0,01 ppm)

• Input probe SCLO1-SCLO2 on terminal

- Conductivity measure and control:

• Measure range: 0 – 10.00 mS via probe SCD K1

Other range available: 1000µS, 100 µS, 10 µS, via probe SCD K5

MICON

measure technology

Measure and control instruments for water treatment


PM-PH, MV, CL, CD

metering dosing pumps

Home

(with measure instrument built-in)

Model

Flow rate

max

(l/h)

Pressure

max

(bar)

Frequency

max

(imp/min)

ml/pulse

Max suction

high

(m)

Standard power

supply (*)

Weight

(kg)

PM 01-15 1 15 120 0,14 2.0 230 V – 50/60 Hz 2,3

PM 02-10 2 10 100 0,33 2.0 230 V – 50/60 Hz 2,3

PM 05-07 5 7 100 0,83 2.0 230 V – 50/60 Hz 2,3

PM 08-10 8 10 120 1,11 2.0 230 V – 50/60 Hz 2,9

PM 20-03 20 3 120 2,60 2.0 230 V – 50/60 Hz 2,9

(*) Other power supply contact the headquarters

Dimensions

Materials

Pump head: polypropylene

(on request: PVC, SS316, PTFE, PVDF)

Diaphgram: PTFE

Connections: polypropylene

Foot filter: polypropylene

Injection valve: polypropylene

Suction tube: PVC crystal

Delivery tube: polyethylene

Lip valves (standard): FPM

(on request: silicon, EPDM, NBR)

Ball valves (on request): Pyrex, Kalretz,

SS316

Seat: FPM

(on request: silicon, EPDM, PTFE, NBR)

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

Via Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


PMX

metering dosing pumps

Home

Metering dosing pumps PMX series

Constant Flow rate

• Led to show pump running and flow regulation knob

Proportional Flow to a 4-20 mA signal

• Led to show pump running

• Pump drive from an external signal between 4 and 20 mA

• 4 mA = 0%, 20 mA = 100% flow rate.

• Level probe input

Proportional flow to a digital signal (e.g.: water-meter pulse-sender)

• Led to show pump running

• 1:1 mode, 1 signal – 1 pump stroke

• Time mode, 1 signal – adjustable dosing time (0-60 sec)

• Key select working mode

• Knob to adjust dosing time (0-60 seconds)

• Level probe input

Fixing bracket for wall or horizontal base installation

MICON

measure technology

Measure and control instruments for water treatment


PMX

metering dosing pumps

Home

Technical features

• IP65 polypropylen plastic box

• Manual bleed valve

• Fixing bracket for wall or horizontal base installation

Model

Max

flow rate

(l/h)

Max

pressure

(bar)

Max

frequency

(imp/min)

ml/stroke

Max suction

high (m)

PMX 02-06 2 6 120 0,28 2.0

PMX 05-05 5 5 120 0,69 2.0

PMX 07-02 7 2 120 0,97 2.0

PMX 10-01 10 1 120 1,39 2.0

(*) Other power supply, please contact the headquarters

Standard

power

supply(*)

230 V – 50/60

Hz

230 V – 50/60

Hz

230 V – 50/60

Hz

230 V – 50/60

Hz

Weight

(kg)

1.9

1.9

1.9

1.9

Dimensions

Materials

Corpo pompa: polypropylene

(on request: PVC, SS316, PTFE, PVDF)

Diaphgram: PTFE

Connections: polypropylene

Foot filter: polypropylene

Injection valve: polypropylene

Suction tube: PVC crystal

Delivery tube: polyethylene

Lip valves (standard): FPM

(on request: silicon, EPDM, NBR)

Ball valves (on request): Pyrex, SS316

Seats: FPM

(on request: silicon, EPDM, PTFE, NBR)

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


Accessories

Home

pH probes

Model

Measure

range

Connection

Max

temperature

Max pressure

PHS-5 0...14 pH Cable 5m + BNC 60°C 6 bar Epoxy diam 12mm

PHS-1,5 0...14 pH Cable 1,5m + BNC 60°C 6 bar Epoxy diam 12mm

Body

PHS-7 0...14 pH S7 60°C 6 bar Epoxy diam 12mm

PHS-11 0...14 pH S7 60°C 6 bar Glass diam. 12mm

PHS-HP 0...14 pH S7 130°C 6 bar Glass diam 12mm

Other version contact the headquarters

Redox (ORP) probe

Model

Measure

range

Connection

Max

temperature

Max pressure

MVS-5 +/- 1000 mV Cable 5m + BNC 60°C 6 bar Epoxy diam 12mm

MVS-1,5 +/- 1000 mV Cable 1,5m + BNC 60°C 6 bar Epoxy diam 12mm

Body

MVS-7 +/- 1000 mV S7 60°C 6 bar Epoxy diam 12mm

MVS-11 +/- 1000 mV S7 60°C 6 bar Glass diam 12mm

MVS-HP +/- 1000 mV S7 130°C 16 bar Glass diam 12mm

Other version contact the headquarters

Cables and extensions

Model

S7- BNC

PL -10

(*) other measures contact the headquarters

Description

Cable with S7 (probe) – BNC (controller)

connections.

Availables length: 1m, 5m, 10m (*)

Extension cable with BNC-BNC connection.

Length 10m (*)

MICON

measure technology

Measure and control instruments for water treatment


Accessories

Home

Chlorine Sensors

Amperometric Cells

Model Description Measure range Max pressure Flow Connection

SCLO-1

Amperometric cell with

Platinum/copper

electrodes

0 – 10 ppm

(mg/L Cl 2 )

8 bar

Suggested

40l/h

cable 2 wires

L = 200mm

SCLO-11

Amperometric cell with

Platinum/copper

electrodes.

Placement for

temperature sensor and

arrangement for flow

sensor

0 – 10 ppm

(mg/L Cl 2 )

8 bar

Suggested

40l/h

cable 2 wires

L = 200mm

SCLO-2

Amperometric cell with

Platinum/copper

electrodes.

Placement for pH, Redox

probes and temperature

sensor. Arrangement for

flow sensor

0 – 10 ppm

(mg/L Cl 2 )

8 bar

Suggested

40l/h

cable 2 wires

L = 200mm

Selective membrane sensor

Model Description Max pressure Flow Features

SCM

Chlorine sensor with

selective membrane and

LED measure status.

PVC body, IP67.

1 bar

Suggested

30...40l/h

Cable length = 2 m

Sensor diameter = 25mm

Sensor length = 175mm

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


Accessories

Home

Turbidity sensor

Model Description Measure range Flow Connection

STB-1

PVC body with

input/output tube 8/12

0 – 40 NTU Suggested 15 l/h

To the controller

M96 – TB

Dissolved oxygen probe

Model Description Measure range Flow Connection

OXY-1

diam 12mm, PG 13,5

mm mounting

0...20 mg/l O 2 Min. 0,03 m/s

Cable 5m for

controller

M96- OXY

Temperature probes

Model Description Connection

STE 1

Measure range: 0 – 100°C

PTFE body

SS316 electrode

½” gas

Cable length = 3m

STE 2

Measure range: 0 – 50°C

PVC body

Internal sensor bult-in

½” gas

Cable length = 3m

Proximity sensor

Model

SP 1

Description

Inductive proximity sensor for

SCLO-11, SCLO-2, PS-4

MICON

measure technology

Measure and control instruments for water treatment


Accessories

Home

Conductivity probes

Model Description Connection

SCD K1

SCDT K1

Constant cell k=1

PVC body

Max temperature 50°C

SS316 electrodes

Internal NTC for temperature compensation

½” gas

Cable length = 3m

SCDL K1

Constant cell k=1

PVC body

Max temperature 50°C

SS316 electrodes

½” gas

Cable length = 3m

SCD K5

SCDT K5

Constant cell k=5

PVC body

Max temperature 50°C

SS316 electrodes

Internal NTC for temperature compensation

½” gas

Cable length = 3m

SCD K1 T

SCDT K1 T

Constant cell k=1

PTFE body

Max temperature 130°C

SS316 electrodes

Internal NTC for temperature compensation

½” gas

Cable length = 3m

SCD K5 T

SCDT K5 T

SCD grafite

SCDT grafite

Constant cell k=5

PTFE body

Max temperature 130°C

SS316 electrodes

Internal NTC for temperature compensation

Constant cell k=0,8

PTFE body

Max temperature 130°C

Graphite electrodes

Internal NTC for temperature compensation

½” gas

Cable length = 3m

½” gas

Cable length = 3m

MICON

St. Trento, 11

02015 Cittaducale (RI)

Tel.: +39.0746.601222

Fax: +39.0746.690121

Web site: www.micon.it

Email: info@micon.it


Accessories

Home

Description

GSM Modem

GSM Modem for instrument with RS232 connection.

Including connection cable Instrument/modem and power

supply device 230V. SIM card not included.

Description

Converter

RS232-485

RS485-232

RS232/485 and RS485-232 converter to connect at the

RS232 output connection of the instrument and to the serial

port of the PC.

Probe-holders

Model

PS-100

Description

Probe-holder on-line for probes diam 12mm.

Connection ½” gas

PS-200

Probe-holder for probes diam 12mm and

conductivity probe SCD series. Max

Temperature 50°C. Max pressure 5 bar.

Allowed for proximity sensor SP1 and little

tubing to take a liquid sample

PS-300

Immersion probe-holder, PVC body,

length = 70 cm, for probes diam 12mm.

PS-4

Probe-holder allowed for 2 probes diam 12mm

(pH, Redox), 1 probe diam 25 mm and

temperature sensor.

Placement for proximity sensor SP1

Buffer solution

Model

BFS

Description

Buffer solutions for controller calibration

Available to ph 4.0 - 7.0 - 9.0 - 475 mV - 84µS ,

12.88mS, 10 NTU

MICON

measure technology

Measure and control instruments for water treatment


Accessories

Home

Accessori

Modello

Descrizione

Suction device

PVC body.

Foot filter and level probe

Length = 70 cm

Level probe

For dosing pumps PM-K (if predisposed), PM-MF and

PM-PH,MV,CL,CD series

Level sensor braket

Plastic bracket to connect level probe or foot filter

Relief valve

Relief valve (250 l/h) threaded connections

with 3/8” GF tube nut.

Multifunction valve

Three functions valve: back pressure (1 bar), antisiphon,

air bleed.

Extension

3/8” (Gm-Gf) injection valve fitting extension in PVC

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


Accessories

Home

Water-meter pulse-sender

Treated connections

Treated water-meter pulse-sender for cold water (max 30 °C), dry-dial magnetic coupling. Cable length 3 m.

Model

Diameter

Inch mm

Pulse/L (*)

Length (mm)

Without connections

WMC - 1/2” 1/2” 13 1 110

WMC - 3/4” 3/4” 20 1 130

WMC - 1” 1” 25 1 160

WMC - 1.1/4” 1” 1/4 30 1 160

WMC - 1.1/2” 1” 1/2 40 1 200

WMC - 2” 2” 50 1 300

Technical data

Model

Nominal flow

(m3/h)

Max flow for few

minutes

(m3/h)

Min flow with accuracy

±5%

(l/h)

Min flow with accuracy

±2%

(l/h)

WMC - 1/2” 1,5 3 30 120

WMC - 3/4” 2,5 5 50 200

WMC - 1” 3,5 7 70 280

WMC - 1.1/4” 5 10 100 400

WMC - 1.1/2” 10 20 200 800

WMC - 2” 15 30 450 3000

Flanged connections

Flanged water-meter pulse-sender for cold water (max 30 °C), dry-dial magnetic coupling. Cable length 3 m

Model Diameter (Inch) Pulse/L (*) Length (mm)

WMH – DN50 2” 100 200

WMH – DN65 2” 1/2 100 200

WMH – DN80 3” 100 225

WMH – DN100 4” 100 250

WMH – DN150 6” 100 300

Technical data

Model

Nominal flow

(m3/h)

Max flow for few

minutes

(m3/h)

P Min flow with accuracy

±5%

(m3/h)

Min flow with accuracy

±2%

(m3/h)

WMH – DN50 15 50 0,45 1

WMH – DN65 25 80 0,75 1,2

WMH – DN80 40 200 1,2 2

WMH – DN100 60 250 1,2 2

WMH – DN150 150 450 2,5 12

MICON

measure technology

Measure and control instruments for water treatment


Accessories

Home

Tanks

Tanks SM series are designed to assembling dosing pumps and mixe rs, to realize a complete dosing skid. It a re made by

centrifugation and have a very good compatibility level with the greater part of chemical product used in dosing applications

Model Capacity Diameter (mm) High (mm)

SM – 100 120 500 680

SM – 300 325 710 890

SM – 500 550 885 1000

SM – 1000 1070 1100 1200

Safety basin

Polyethylene safety basin VM series are designed to contain our tanks SM series

Modello Capacity Diameter (mm) High (mm)

VM – 100 120 700 450

VM – 300 325 900 660

VM – 500 600 1050 1000

VM – 1000 1000 1320 980

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it


Portable Instruments

Home

COOL POOLTESTER

Cool Pooltester is a portable phot ometer very easy to use. The reagent

tablets are safe and easy to handle. There are no powders or liquids to spill.

All tablets are available in handy refill packs. The tests are quick and simple

to perform - a reagent tablet is mixed with a water sample, the test tube is

placed in the instrument and the test selected with a menu button.

Handbag included. To m easure free Chlorine, total Chlorine, pH and

Cyanuric acid. Complete of: battery, instruction manual, 2 glass test-tube, 1

spatula and 1 refill pack.

Measure range

Power supply

Dimensions

Weight

0,1...5,0 mg/l Chlorine

6,8...8,4 pH

0...200 mg/l Cyanuric Acid

1 battery PP3 – 9V

17,5 x 7,5 x 4,5 cm

132 g

XS SERIES

Wide display easy to read. Self-turnoff f unction. Automatic temperature compensation. Rubber

protective shell and water proof keypad. Handbag with included buffer soluti ons, temperature

sensor and accessories.

XS PH6, pH and Redox (mV) measure

Measure range pH 0..14,00, accuracy ±0,01 pH

Measure range Redox ±1000 mV, accuracy ±2mV

Manual or automatic temperature compensation (0..100°C)

4 batteries “AAA”

Worktime batteries >200 hours

Self-turnoff after 17 min

Working temperature 0..50 °C

Instrument dimensions:

14x7x3,5 cm (weight 200 g)

Handbag dimensions:

27x35x7,5 cm (weight 1,7 kg)

XS COND6, conductivity measure

Measure range with C=1

0..199,9-1999µS/19,99-199,9µS, accuracy ±1%

Measure range with C=0,1

0..19,99-199,9-1999µS /19,99mS, accuracy ±1%

Measure range with C=10

0..199,9-1999µS /19,99-199,9mS, accuracy ±1%

Manual or automatic temperature compensation (0..100°C)

MICON

measure technology

Strumenti di misura e controllo per trattamento acqua


Portable Instruments

Home

PC compact

5 IN 1

Total and free Chlorine, pH, Cyanuric Acid,

Total alkalinity and hardness (Calcium).

Included reagent tablet for all test type.

COD

• LED with high stability light

• Wide digital display

• Easy to use

• Complete of handbag

• Chip, compact and manageable

TURBIDITY

• Infrared light system

• 4 measure range 0-2000 TE/F or FNU/NTU

• SMD microprocessor technology

• LED with high stability light

• Measure of colored liquids

• Supplied ready to use with accessories

standard of calibrations

Practical

PC COMPACT photometers are compact unit, with an ergonomic design, a

LCD display easy t o re ad mea sure ar ea c ompletely protec t, LED light with

constant emission.

Portable

Every photometer is set for each method measure and provides for fast and

accurate results. Thanks to the comfortable handbag and the b attery power

supply, PC COMPACT is usable any where. The handbag con tain al so 50

reagent tablet for each parameter (not COD).

Tel.: +39.0746.601222

Fax: +39.0746.690121

MICON

St. Trento, 11

02015 Cittaducale (RI)

Web site: www.micon.it

Email: info@micon.it

More magazines by this user
Similar magazines