6. Starting the Diesel Hammer<br />

Installation of the tripping device<br />

1. Attach the lower and one upper guide gibs<br />

to the tripping device. In U- type leads the<br />

tripping device is guided directly at starter<br />

guides mounted to the Diesel Pile Hammer<br />

(see page 1-2).<br />

2. Place the wire rope in the rope sheave or for<br />

smaller hammer types connect the wire rope<br />

directly to the sheave pin. To do so, you must<br />

remove the sheave pin and install it again<br />

when the wire rope is positioned. Secure the<br />

sheave pin with the safety screw or cotter pin.<br />

3. Lift the tripping device upward and make sure<br />

it is smoothly sliding.<br />

Lowering the tripping device<br />

1. Pull the lever (A2) down to the stop using the<br />

rope and keep it taut. This retracts the driving<br />

pin (A3) in a vertical position. The tripping<br />

device can move past the lifting dogs (6) of<br />

the Diesel Pile Hammer.<br />

2. Lower the tripping device to the lower stop<br />

(9). The trip cam lever (A5) is pushed upward<br />

at the trip cam lever engaging point (9). Pawl<br />

(A4) is thus pushed out and into the lifting<br />

groove of the piston weight (26).<br />

4. Attach the rope (in the toolbox) to the lever<br />

(A2).<br />

Operating mode<br />

You must keep a distance of at least 13 feet<br />

(4 meters) from the Diesel Pile Hammer.<br />

111 Berry Road<br />

Houston, TX 77002<br />

Tel. (713) 691-3000<br />

Fax (713) 691-0089<br />

E-mail: info@bauerpileco.com<br />