20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

IEC Squirrel-Cage Motors<br />

Non-standard motors frame size 315 and above<br />

Special versions<br />

Special versions<br />

Additional Motor type frame size<br />

identification<br />

code<br />

-Z with<br />

order<br />

code and<br />

plain text if<br />

required<br />

315 355 400 450<br />

Forced-air cooled motors with externally-mounted fan for converter-fed operation 1PQ8<br />

1PQ8<br />

Converter-fed operation<br />

Packaging, safety notes, documentation and test certificates (continued)<br />

Normal inspection (routine inspection) F01 ✓ ✓ ✓ ✓<br />

with acceptance<br />

Visual acceptance and report handover F03 ✓ ✓ ✓ ✓<br />

with acceptance<br />

Temperature-rise test, without<br />

F04 ✓ ✓ ✓ ✓<br />

acceptance<br />

Temperature-rise test, with acceptance F05 ✓ ✓ ✓ ✓<br />

Noise measurement during idling, F28 ✓ ✓ ✓ ✓<br />

no noise analysis, no acceptance<br />

Noise measurement during idling, F29 ✓ ✓ ✓ ✓<br />

no noise analysis, with acceptance<br />

Noise measurement in no-load<br />

F62 ✓ ✓ ✓ ✓<br />

operation, with noise analysis,<br />

without acceptance<br />

Noise measurement during idling, F63 ✓ ✓ ✓ ✓<br />

with noise analysis, with acceptance<br />

Recording of current and torque curves F34 – – – –<br />

with torque metering shaft during starting,<br />

without acceptance<br />

Recording of current and torque curves F35 – – – –<br />

with torque metering shaft during starting,<br />

with acceptance<br />

Measurement of locked-rotor torque F52 – – – –<br />

and current, without acceptance<br />

Measurement of locked-rotor torque F53 – – – –<br />

and current, with acceptance<br />

Type test with heat run for<br />

F82 ✓ ✓ ✓ ✓<br />

horizontal motors, without acceptance<br />

Type test with heat run for<br />

F83 ✓ ✓ ✓ ✓<br />

horizontal motors, with acceptance<br />

Type test with heat run for<br />

F92 ✓ ✓ ✓ ✓<br />

vertical motors, without acceptance<br />

Type test with heat run for<br />

vertical motors, with acceptance<br />

F93 ✓ ✓ ✓ ✓<br />

p Standard version<br />

† With no extra charge<br />

• This order code only determines the price of the version -<br />

Additional plain text is required.<br />

O. R. Possible on request<br />

✓ With extra charge<br />

– Not possible<br />

3<br />

1)<br />

For appropriate tripping unit, see <strong>Catalog</strong>ue LV 1.<br />

2)<br />

The standard thermistors are omitted. If PTC thermistors are required as<br />

well as KTYs or PT100s, this must be specified in the order in plain text.<br />

3)<br />

Only possible in combination with the larger connection boxes 1XB1 621<br />

or 1XB1 631 (order codes M58 or L00).<br />

4)<br />

With 1PQ8 357-2 and 1PQ8 357-4, connection box 1XB1 631 is supplied<br />

in the standard version.<br />

5)<br />

Standard version for 1PQ8 357-2 and 1PQ8 357-4.<br />

6)<br />

Not possible for converter operation.<br />

7)<br />

Only possible for main motor – Not possible for separately driven fan.<br />

8)<br />

Site altitude up to 1000 m above sea level.<br />

9)<br />

Explosion-protected encoders are available on request.<br />

10) Only permitted for use in accordance with temperature class B. PTC thermistors<br />

for temperature class B are included. For compliance with temperature<br />

class B, derating is necessary in the case of converter-fed operation<br />

in Zones 2 and 22. Derating data are available on request.<br />

11) These motors do not have a rated voltage range stamped on the rating<br />

plate.<br />

12) In the order, the "Speed range and torque characteristic" must be specified<br />

in plain text. A system test is necessary for M = constant.<br />

13) Not possible for 2-pole motors and motors of vertical type of construction.<br />

14) When ordering, specifiy in plain text: Voltage, frequency and circuit.<br />

15) A combination with the order codes M72, M73, M35, M39, K30, C27, M88<br />

and M50 is not possible. Connection box 1XP1 634 can be rotated through<br />

4 x 90°. Cable entry is from NDE or the delivery position. Dimension drawings<br />

available on request.<br />

16) Only possible for main motor – Not possible for separately driven fan<br />

motor.<br />

Siemens D81.1 · 2006<br />

3/51

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!