20.09.2015 Views

Catalog

Old Catalog Motor 2006.pdf - Motology

Old Catalog Motor 2006.pdf - Motology

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

IEC Squirrel-Cage Motors<br />

Explosion-proof motors<br />

Self-ventilated, in Zone 1 with type of protection "e"<br />

Aluminium series 1MA7<br />

■ Selection and ordering data (continued)<br />

Order No.<br />

Locked-rotor<br />

torque<br />

Locked-rotor<br />

current<br />

with direct starting as multiple of rated<br />

torque current torque<br />

Breakdown torque Torque<br />

class<br />

Moment<br />

of inertia Noise t E time<br />

Measuringsurface<br />

sound<br />

pressure level<br />

at 50 Hz<br />

Sound<br />

pressure<br />

level<br />

at 50 Hz<br />

for<br />

temperature<br />

class<br />

T1/T2<br />

T LR /T rated I LR /I rated T B /T rated CL J L pfA L WA t E t E<br />

kgm² dB(A) dB(A) s s<br />

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

temperature classes T1 to T3<br />

1MA7 060-2BAqq 2.3 4.4 2.3 16 0.00018 49 60 30 27<br />

1MA7 063-2BAqq 2.2 4.4 2.3 16 0.00023 49 60 19 16<br />

1MA7 070-2BAqq 2.3 5.6 2.1 16 0.00035 52 63 28 25<br />

1MA7 073-2BAqq 3 5.2 2.6 16 0.00045 52 63 18 13<br />

1MA7 080-2BAqq 2.5 6.2 2.7 16 0.00085 56 67 13 11<br />

1MA7 083-2BAqq 2.8 6.4 3 16 0.0011 56 67 12 10<br />

1MA7 090-2BAqq 2.6 6.2 2.8 16 0.0015 60 72 12 11<br />

1MA7 096-2BAqq 2.8 7.2 2.8 16 0.002 60 72 9 8<br />

1MA7 106-2BAqq 2.6 7.4 2.8 16 0.0038 62 74 9 8<br />

1MA7 113-2BBqq 2.1 6.6 2.3 13 0.0055 63 75 10 9<br />

1MA7 130-2BBqq 1.9 6.8 2.5 13 0.016 68 80 15 13<br />

1MA7 131-2BBqq 2.2 7.7 2.7 13 0.021 68 80 15 13<br />

1MA7 163-2BBqq 2.2 7.6 3.1 13 0.034 70 82 29 18<br />

1MA7 164-2BBqq 2.1 7.6 2.9 13 0.04 70 82 23 12<br />

1MA7 166-2BBqq 2.3 7.6 3 13 0.052 70 82 21 9<br />

for<br />

temperature<br />

class<br />

T3<br />

4<br />

Order No.<br />

Locked-rotor<br />

torque<br />

Locked-rotor<br />

current<br />

Breakdown<br />

torque<br />

with direct starting as multiple of rated<br />

torque current torque<br />

Torque<br />

class<br />

Moment<br />

of inertia Noise t E<br />

for<br />

time<br />

Measuringsurface<br />

sound<br />

pressure level<br />

at 50 Hz<br />

Sound<br />

pressure<br />

level<br />

at 50 Hz<br />

temperature<br />

class<br />

T1/T2<br />

T LR /T rated I LR /I rated T B /T rated CL J L pfA L WA t E t E<br />

kgm² dB(A) dB(A) s s<br />

2-pole, 3000 rpm at 50 Hz, 3600 rpm at 60 Hz, temperature class F, IP55 degree of protection,<br />

temperature classes T1 and T2, with double rating plate (T1/T2 and T3)<br />

1MA7 131-2BBqq 1.9 6.5 2.3 13 0.021 68 80 12 7<br />

1MA7 163-2BBqq 1.7 6 2.4 13 0.034 70 82 24 –<br />

1MA7 164-2BBqq 1.6 5.8 2.2 13 0.04 70 82 16 –<br />

1MA7 166-2BBqq 1.8 5.8 2.3 13 0.052 70 82 15 –<br />

t E time<br />

for<br />

temperature<br />

class<br />

T3<br />

1)<br />

2)<br />

3)<br />

4)<br />

With voltage code "9", separate versions for T1, T2 and T3. For order code<br />

A11, only one output possible in each case.<br />

Utilization according to temperature class F.<br />

The following applies for explosion-proof motors: In the case of the types<br />

of construction with shaft end down, the version "with protective cover" is<br />

required. For types of construction with shaft extension pointing upwards,<br />

a suitable cover must be implemented to prevent small parts from falling<br />

into the fan cover (see the standard IEC/EN 60079-0). The cover must not<br />

block the cooling air-flow.<br />

The "Second shaft extension" option, order code K16 is not possible.<br />

Siemens D 81.1 · 2006<br />

4/13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!