Precautions to be taken with a connected motor<br />

If work must be carried out on a connected motor or on the driven machine, the mains voltage<br />

must always be disconnected from the variable speed drive first. Wait at least 5 minutes<br />

before starting work.<br />

Short-circuits<br />

The Inverter has high voltage parts inside which, if short-circuited, might cause damage to<br />

itself or other property. Place covers on the openings or take other precautions to make sure<br />

that no metal objects such as cutting bits or lead wire scraps go inside when installing and<br />

wiring.<br />

Earth leakage current<br />

This variable speed drive has an earth leakage current which does exceed 3.5 mA AC.<br />

Therefore the minimum size of the protective earth conductor must comply with the local<br />

safety regulations for high leakage current equipment which means that according the<br />

standard IEC61800-5-1 the protective earth connection must be assured by one of following<br />

conditions:<br />

1. Use a protective conductor with a cable cross-section of at least 10 mm 2 for copper (Cu)<br />

or 16 mm 2 for aluminium (Al).<br />

2. Use an additional PE wire, with the same cable cross-section as the used original PE and<br />

mains supply wiring.<br />

Residual current device (RCD) compatibility<br />

This product cause a DC current in the protective conductor. Where a residual current<br />

device (RCD) is used for protection in case of direct or indirect contact, only a Type B RCD is<br />

allowed on the supply side of this product. Use RCD of 300 mA minimum.<br />

Voltage tests (Megger)<br />

Do not carry out voltage tests (Megger) on the motor, before all the motor cables have been<br />

disconnected from the variable speed drive.<br />

Precautions during Autoreset<br />

When the automatic reset is active, the motor may restart automatically provided that the<br />

cause of the trip has been removed. If necessary take the appropriate precautions.<br />

Heat warning<br />

Be aware of specific parts on the VSD having high temperature. Do not touch the Inverter fins,<br />

braking resistors and the motor, which may become too hot during the power supply and for some<br />

time after the power shut-off. Doing so may result in a burn.<br />

Do not Operate the inverter with wet hands<br />

Do not operate the Digital Operator or switches with wet hands. Doing so may result in a<br />

serious injury due to an electric shock.<br />