20.09.2015 Views

Rohrfeder-Manometer EN 837-1 Bourdon Tube Pressure Gauge

Rohrfeder-Manometer EN 837-1 Bourdon Tube Pressure Gauge

Rohrfeder-Manometer EN 837-1 Bourdon Tube Pressure Gauge

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ARMATUR<strong>EN</strong>-WOLFF ∙ Friedrich H. Wolff GmbH & Co. KG<br />

Oehleckerring 29 ∙ 22419 Hamburg - Germany<br />

Tel. +49 40 532873-0 ∙ Fax +49 40 532873-29<br />

E-Mail: aw@armaturen-wolff.de ∙ Internet: www.armaturen-wolff.de<br />

<strong>Rohrfeder</strong>-<strong>Manometer</strong> <strong>EN</strong> <strong>837</strong>-1<br />

Gehäuse ABS / Innenteile Messing<br />

AW 900: <strong>Rohrfeder</strong>-<strong>Manometer</strong><br />

AW 901: Mano-Vakuummeter<br />

<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauge</strong><br />

body ABS, inner parts brass<br />

AW 900: bourdon tube pressure gauge<br />

AW 901: vacuumeter<br />

AW-Nr.<br />

AW no.<br />

Pos.<br />

item<br />

Bezeichnung<br />

denomination<br />

Werkstoff<br />

material<br />

nach DIN <strong>EN</strong><br />

acc. to DIN <strong>EN</strong><br />

Werkstoff-Nr.<br />

material no.<br />

900<br />

901<br />

1 Gehäuse / body ABS<br />

2 Meßglied / measuring element Kupferlegierung / copper alloy<br />

3 Anschluß / connection Messing / brass<br />

4 Sichtscheibe / front glass Kunststoff / plastic<br />

Anwendung<br />

Für gasförmige und flüssige, nicht hochviskose und<br />

nicht kristallisierende Medien, die Kupferlegierungen nicht angreifen.<br />

Achtung:<br />

Bei Medium Gas oder Dampf unbedingt Tabelle<br />

"Auswahlkriterien gemäß <strong>EN</strong> <strong>837</strong>-2" beachten!<br />

Verwendungsbereich<br />

Ruhende Belastung: 3/4 x Skalenwert<br />

Dynamische Belastung: 2/3 x Skalenwert<br />

Kurzzeitig:<br />

Skalenendwert<br />

Messstofftemperatur max. +60°C<br />

Umgebungstemperatur -20°C bis + 60°C<br />

Temperaturverhalten<br />

Anzeigefehler bei Abweichung von der Normaltemperatur 20°C<br />

am Messsystem:<br />

bei Temperaturzunahme ca. ±0,4 %/10 K<br />

bei Temperatureabnahme ca. ±0,4 %/10 K<br />

vom jeweiligen Skalenwert<br />

Schutzart IP 32 (<strong>EN</strong> 60529)<br />

Genauigkeitsklasse 1,6 (<strong>EN</strong> <strong>837</strong>-1/6)<br />

Anzeigebereiche (<strong>EN</strong> <strong>837</strong>-1/5)<br />

-1/0 bis -1/+15 bar<br />

0/0,6 bis 0/400 bar<br />

Application<br />

For gaseous and liquid media which are not highly viscous,<br />

do not cristallize and do not attack copper alloys.<br />

Attention:<br />

When measuring gas or vapour, the instruments must be used in<br />

accordance with the safety recommendations of <strong>EN</strong> <strong>837</strong>-2!<br />

Application Area<br />

static load:<br />

3/4 x full scale value<br />

dynamic load:<br />

2/3 x full scale value<br />

short term:<br />

full scale value<br />

Medium Temperature max. +60°C<br />

Ambient Temperature -20°C up to + 60°C<br />

Temperature Performance<br />

Indication error when the temperature of the measuring element<br />

deviates from 20°C:<br />

rising temperature<br />

approx. ±0,4 %/10 K<br />

falling temperature<br />

approx. ±0,4 %/10 K<br />

percentage of full scale value<br />

Protection IP 32 (<strong>EN</strong> 60529)<br />

Accuracy Class 1,6 (<strong>EN</strong> <strong>837</strong>-1/6)<br />

Ranges (<strong>EN</strong> <strong>837</strong>-1/5)<br />

-1/0 up to -1/+15 bar<br />

0/0,6 up to 0/400 bar<br />

Maße und Gewichte können je nach Hersteller abweichen / depending on manufacturers measures and weight can change<br />

1110/AW900-901/50445<br />

Technische Änderungen vorbehalten / Alterations reserved<br />

H - 01.00


ARMATUR<strong>EN</strong>-WOLFF ∙ Friedrich H. Wolff GmbH & Co. KG<br />

Oehleckerring 29 ∙ 22419 Hamburg - Germany<br />

Tel. +49 40 532873-0 ∙ Fax +49 40 532873-29<br />

E-Mail: aw@armaturen-wolff.de ∙ Internet: www.armaturen-wolff.de<br />

<strong>Rohrfeder</strong>-<strong>Manometer</strong> <strong>EN</strong> <strong>837</strong>-1<br />

<strong>Bourdon</strong> <strong>Tube</strong> <strong>Pressure</strong> <strong>Gauge</strong><br />

Nenngröße / nominal size (NG) 40/50/63<br />

NG<br />

a<br />

b<br />

s<br />

NG<br />

b 1<br />

s<br />

øe<br />

SW1<br />

h<br />

SW<br />

c2<br />

A<br />

Anschluß radial<br />

bottom pressure entry<br />

c1<br />

G<br />

øc<br />

Nenngröße / nominal size (NG) 80<br />

b<br />

NG<br />

s<br />

a<br />

h<br />

SW<br />

c2<br />

G1<br />

e 1<br />

e 2<br />

g<br />

C<br />

Anschluß axial<br />

back pressure entry<br />

b 1<br />

NG<br />

s<br />

øe<br />

SW1<br />

G1<br />

e 1<br />

e 2<br />

g<br />

A<br />

Anschluß radial<br />

bottom pressure entry<br />

c1<br />

G<br />

øc<br />

C<br />

Anschluß axial<br />

back pressure entry<br />

Nenngröße / nominal size (NG) 100<br />

NG<br />

b<br />

s<br />

NG<br />

b 1<br />

s<br />

a<br />

øe<br />

SW1<br />

G1<br />

h<br />

e 1<br />

e 2<br />

SW<br />

c2<br />

g<br />

A<br />

Anschluß radial<br />

bottom pressure entry<br />

c1<br />

G<br />

øc<br />

C<br />

Anschluß axial<br />

back pressure entry<br />

NG a b b1 øc c1 c2 øe e1 e2 g G G1 h s sw sw1<br />

40 9,5 25 25 4 2 10 - - - 41,5 G1/8B G1/8B 36 3 12 -<br />

50 10,3 26,8 27,1 5 2 13 - - - 47,5 G1/4B G1/4B 45 3,8 14 -<br />

63 9,8 29,7 30,4 5 2 13 - - - 50,4 G1/4B G1/4B 51,5 3,7 14 -<br />

80 12,8 32,8 32,8 6 3 20 5 2 13 55,8 G1/2B G1/4B 72 2,8 22 14<br />

100 15,5 34,5 32 6 3 20 5 2 13 55 G1/2B G1/4B 82 3,5 22 14<br />

Maße und Gewichte können je nach Hersteller abweichen / depending on manufacturers measures and weight can change<br />

H - 01.01<br />

Technische Änderungen vorbehalten / Alterations reserved<br />

1110/AW900-901/50445