WNIP NOV DEC 19.6 DIGITAL
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
20<br />
<strong>19.6</strong><br />
Wide range of test units for safety valves<br />
wide range of test units are<br />
A available for safety valves.<br />
From analogue, digital to semiautomatic<br />
(computerized) test<br />
systems for testing and (re)<br />
adjusting the set pressure,<br />
seat tightness and general<br />
performance with gas or liquid<br />
test systems, range 0 – 1000 bar /<br />
14,500 PSI.<br />
The test units can be equipped<br />
with a variety of parts and systems,<br />
for example pressure – vacuum test<br />
systems for breather valves and<br />
other tank safety valves up to 24”.<br />
Model: VC-SRV<br />
° Testing with both Gas and<br />
Liquid.<br />
° Rigid Design with high quality<br />
finish.<br />
° Standard completed with<br />
the unique Ventil Computer<br />
registration Systems.<br />
° According to all common<br />
international standards and<br />
directives.<br />
° Stainless steel control panel and<br />
liquid reservoir.<br />
Model: VC-SP-T4<br />
° Compact design for the use<br />
in containers or other small<br />
workshops.<br />
° Rigid design with high quality<br />
finish<br />
Model: CT800-T4<br />
° Fully Equipped test unit for<br />
testing and (re)adjusting all<br />
common types of tank relief<br />
valves.<br />
° The CT800 is completed with<br />
dual range test system for testing<br />
both in pressure and vacuum<br />
conditions.<br />
° Specifically designed to verify<br />
the settings and leak rates<br />
according to clean air emissions<br />
control acts and test standard<br />
API2000.<br />
° Available as stand-alone unit or<br />
as an optional module with other<br />
safety valve test units.<br />
PreVenTest, In-Situ testing of<br />
PSV’s<br />
Ingeniously designed systems<br />
for testing all types of spring<br />
operated PSV’s In-Situ, in process<br />
and under normal operating<br />
conditions.<br />
The portable system enables you<br />
to provide the correct working<br />
and performance or identify<br />
PSV’s in need of repair without<br />
plant shut-down.<br />
The PreVenTest system is<br />
available in 2 types;<br />
° PreVenTest LTC, lightweight,<br />
hand controlled and battery<br />
driven.<br />
° PreVentTest Advance, fully<br />
automatic.<br />
° No plant shut-down<br />
° No dismantling of the valve<br />
° No loss of productivity<br />
° No loss of profitability<br />
admin@atts.co.za<br />
Range of process calibration tools<br />
Offering a range of process<br />
calibration tools for<br />
process environments such as<br />
pharmaceutical, refining or other<br />
industrial areas at a bench, out in<br />
the plant, or in the field.<br />
Electrical and multifunction<br />
calibration<br />
Fluke’s broad range of field<br />
and bench calibrators source,<br />
simulate, and measure pressure,<br />
temperature, and electrical<br />
signals to help verify and adjust<br />
test equipment or almost any<br />
process instrument.<br />
mA loop calibration<br />
Loop calibrators are essential<br />
tools for working with 4-20<br />
mA current loops. Fluke loop<br />
calibrators provide mA sourcing,<br />
simulation and measurement,<br />
readouts in both mA and % of<br />
span, 24 V loop supply, simple<br />
operation and reliable accuracy.<br />
Pressure calibration<br />
Instrumentation is found<br />
in virtually every process plant.<br />
Periodic calibration of these<br />
instruments is required to keep<br />
plants operating efficiently and<br />
safely.<br />
Fluke provides a wide<br />
selection of field and bench<br />
calibration tools to quickly<br />
and reliably calibrate pressure<br />
instrumentation.<br />
Temperature calibration<br />
Temperature calibration<br />
refers to the calibration of any<br />
device used in a system that<br />
measures temperature—from<br />
sensors to transmitters to<br />
displays.<br />
Fluke offers bench and field<br />
solutions to ensure process<br />
temperature accuracy of not<br />
only the system’s electronic<br />
temperature signals, but also the<br />
very temperature sensors that<br />
initiate those signals.<br />
• Fluke 7526B precision<br />
process calibrator – the best<br />
balance of economy and<br />
accuracy for calibration of<br />
temperature and pressure<br />
process measurement<br />
instrumentation.<br />
• Fluke 754 HART<br />
multifunction documenting<br />
process calibrator - This field<br />
and bench calibrator sources,<br />
simulates, and measures<br />
pressure, temperature,<br />
and electrical signals with<br />
exceptional precision.<br />
• Fluke 718-300G pressure<br />
calibrator with pump provides<br />
a total pressure calibration<br />
solution for transmitters,<br />
gauges and switches with<br />
pressure source and milliamp<br />
measurement to calibrate and<br />
maintain almost any pressure<br />
device.<br />
• Fluke P3100 hydraulic<br />
deadweight tester - High quality,<br />
high performance, easy to use<br />
oil pressure calibration.<br />
• Fluke 726 multifunction<br />
process calibrator is designed<br />
specifically for the process<br />
industry with broad workload<br />
coverage, calibration<br />
power and unsurpassed<br />
accuracy<br />
• Fluke 9144 field<br />
temperature metrology well -<br />
Lightweight and portable field<br />
dry-well small enough to easily<br />
carry in one hand. (50 °C to 660<br />
°C and accurate to ± 0.1 °C)<br />
sales@comtest.co.za