Radiation Testing

Sample Size/Traceability

Sample Size:

Total Ionizing Dose. Minimum 5 samples.

4 test, 1 reference.

Single Event. 3 samples recommended.

Traceability:

Traceability

Use single Lot-Date Lot Date-Code Code for test and flight

hardware.