Water bottom measurement<br />

___________________________________________________________________________<br />

5 Water bottom measurement<br />

5.1 Introduction water bottom measurement<br />

The water bottom probe is based on a capacitive measurement principle. The probe is one plate of the capacitor<br />

and earthed, electrically conducting parts as water and the tank shell, is the other plate. A change in water level is<br />

detected by the water bottom probe as a change in capacitance.<br />

5.1.1 Water probe versions<br />

There are three different water probe versions which can be interfaced:<br />

• The 765 VITO water probe;<br />

• The 766 VITO combi probe;<br />

• The 768 VITO combi probe<br />

The 765 VITO water probe, the 766 VITO combi probe and the 768 VITO combi probe are connected to the 762<br />

VITO Interface, which is connected to the HCU board or ICU-HPI board in the level gauge or indicator.<br />

Figure 5.1 VITO water probes<br />

Instruction manual VITO Page 35