12.09.2017 Views

118_4416655_Rev06

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Introduction VITO Interface and average temperature probes<br />

___________________________________________________________________________<br />

The 764 and 766 VITO temperature probes have 16 elements. These elements are thermocouples, and at the<br />

cold junction a highly accurate Pt100 resistor is located to measure the absolute temperature.<br />

The 767 and 768 VITO LT temperature probes are similar to the 764 and 766 temperature probes, but only have<br />

9 elements.<br />

An MRT (Multiple Resistance Thermometer) or Variable Length Thermometer comprises a number of resistance<br />

elements of different lengths, all starting close to the bottom end of the temperature probe.<br />

An MPT probe (Multiple Pt100 spots) consisting of 1 through 14 RTD's with 2 common ground wires.<br />

More information about the different temperature probes can be found in the introduction section of chapters 2, 3<br />

and 4.<br />

The Honeywell Enraf level gauge must be equipped with a suitable option board to receive the signal from the<br />

762 VITO Interface:<br />

• HCU option board for Honeywell Enraf 854 servo level gauges and 877 FDI;<br />

• ICU_HPI option board for Honeywell Enraf 97x SmartRadar level gauges<br />

• FII-VT board<br />

for Honeywell Enraf 990 SmartRadar FlexLine<br />

This instruction manual describes the commissioning settings in conjunction with the Honeywell Enraf 854 servo<br />

level gauges, the 877 Field Display & Interface and the 97x SmartRadar level gauges. The commissioning of the<br />

different type of probes is divided over the following chapters:<br />

• Average temperature with VITO (combi) probes: chapter 2<br />

• Average temperature with MRT: chapter 3<br />

• Average temperature with MPT or 2 – 3 spots: chapter 4<br />

• Water bottom measurement: chapter 5<br />

Refer to the Commissioning manual SmartRadar FlexLine for the average temperature commissioning and water<br />

bottom settings with the 990 SmartRadar FlexLine.<br />

Instruction manual VITO Page 7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!