A family-run firm from Austria with a workforce of 220 employees, KATZBECK has manufactured bespoke windows and doors made of wood and wood/aluminium for over 65 years. KATZBECK products stand for first-rate design, innovation, outstanding quality and green production processes. KATZBECK is your competent and capable partner in all stages of door and window production, from consulting and planning, to manufacture and installation. Open your senses and find inspiration for your home. Select from a broad range of models, colours and forms; create precisely the atmosphere in your ‘four walls’ that best suits your style. Visit our headquarters and production facility in Rudersdorf or one of our eight window studios in Austria.

11. Care and Maintenance

11. Care and Maintenance Work for Fittings (effective for ALL types of fittings) 1. Aside from regular cleaning, window and door fittings also require professional, systematic inspections and maintenance in order to guarantee serviceability and safety. Therefore we recommend having respective maintenance work conducted, KATZBECK will be happy to consult! Only use neutral cleaning and treatment agents that will not harm the corrosion protection of the fittings and also do not contain abrasives. 2. Fittings must never be painted over. 3. Grease all moving and respective locking parts regularly. Especially heavily stressed gliding areas (such as fall bevel, automatic tracer pins on front door locks as well as gliding parts of hidden fittings, etc.). Do not apply any lubes, rust dissolvers or silicone sprays, only use grease or technical Vaseline or adhesive lubricants with PTFE as spray, e.g. OKS 3751 or similar (Haberkorn Company, Art. No. 79937). Operate the fitting several times after application in order to distribute the lubricant. 4. Test any parts of fittings relevant to safety regularly to make sure they are tightly attached and check for wear and tear. Tighten mounting screws and exchange faulty components if necessary. Mandatory intervals of inspection and check ups: We expressly note that the BASIC PREREQUISITE for obtaining warranty is the compliance with and documentation of the intervals of inspection, check ups and maintenance stated below. We reserve the right to request submission of documentation of the intervals of inspection, check ups and maintenance performed in the event of claims. In the least, included therein should be the date, type of work conducted, name of person and/or company, and material applied. 12 KATZBECK-MANUAL

Verifiable primary check 6-18 months after installation; subsequently every 3-5 years for private users and every 6-18 months for commercial use (depending on intensity of strain) Check the motion of the window and/or of the French door and the ease of movement of the handle when in closed position (precisely vertical and downwards) – if necessary allow certified professionals to re-adjust and re-align the windows and/or French doors. Check for obvious signs of damage as well as wear and tear (abrasion) of all fittings and locking components – if necessary allow certified professionals to exchange components. end user specialized company Check functioning of all moving fittings and locking components and grease these. Verifiable primary check 6-18 months after installation; subsequently every 3-5 years for private users and every 6-18 months for commercial use (depending on intensity of strain) Check mounting screws and tighten and/or replace if necessary. end user specialized company Check lifting stop and re-adjust if necessary. Check the adjustment and/or contact pressure of the (efficient ventilating) cross arms and/or of the edge bearing hinges. Check the contact pressure of the locking pins and/or of the i.s. pins and re-tighten if necessary. Maintenance work marked by an X in the above chart may only be performed by licensed professionals, NEVER by the customer! Unhinging and remounting windows and door leafs, as well as any and all adjustments, may only be completed by a specialized tradesman. Maintenance of components relevant to safety (e.g. corner and cross bearings, turning hinges of front doors, …) may also only be performed by authorized specialized tradesmen! In order to prevent so-called “dormant wear” of fittings, windows and doors have to be operated at least once a month. 12. Operation and Incorrect Operation of Visible and Hidden TT-Fittings Operation Tilted position of the sash (for continuous ventilation of the room) Opening to a gap or night-vent position of the sash (for longer airing at low outdoor temperatures) Rotational position of the sash (for short-term ventilation and rapid ventilation of the room or cleaning the outside windows) Closed position of the sash (if the room is unattended or no ventilation is desired) KATZBECK-MANUAL 13