Graco Elektr. Pumpen

Controllers Solid-State

Controllers Solid-State Timer Features and Benefits The Solid-State Timer from Graco operates on standard 115/230 VAC 50/60 Hz input power, and provides a total on and off cycle with “on” periods to meet your specific lubrication system’s requirements. Total cycle times can be set from 1/2 minute to 32 hours. “On” time during the total cycle time can be set from 12 seconds to 13 minutes. The “on” time occurs at the beginning of each period. • Solid-state technology combined with multiple-level protection ensures dependable performance • Exceptional flexibility of settings allows this timer to be used with many types of simple or sophisticated lubrication systems • Manual run button can be used to check system integrity as well as to simplify system filling and air purging • Face-mounted LED displays timer status at a glance • Tamper-resistant design puts cycle setting controls inside the covered case • Easy mounting and installation • Built-in memory keeps the timer “alive” for 1-1/2 hours during power failures and machine shutdown 562872 Controllers Technical Specifications Electrical .......................................................................................................115/230 VAC; 50/60 hz; 3 ampere (max.) Temperature Range: Operating .............................................................................................................................0º to131º F (-18º to 55º C) Storage ............................................................................................................................ -67º to185º F (-55º to 85º C) Enclosure ........................................................................................................................................High Impact Plastic Component Technology ......................................................................................................................Solid-State CMOS Cycle Interval, Adjustable: Range 1 .............................................................................................................................................0.5 - 30 minutes Range 2 .................................................................................................................................................0.5 - 32 hours “On” Time ..........................................................................................................................................0.2 - 13 minutes Vibration ...................................................................................................................................................... 5g’s 50 Hz Standard: LED Indicator, Manual Run Button Ordering Information Solid State Timer 562872 115/230 VAC 558031 Solid state (SS) timer board only without enclosure DC Timer 557925 DC timer 98 www.graco.com

Controllers WMP III Maxi-Monitor ® Features and Benefits The WMP Ill Maxi-Monitor is a micro processor based controller, dedicated to the operation and monitoring of a centralized lubrication system. WMP Ill is designed to schedule lube intervals and monitor the operation of Trabon pumps and divider valves in intermittent operating systems. • Lube programs can be changed to meet changing conditions or work schedules • High flexibility means you can handle a variety of applications with the same basic WMP Controller • By working with one basic unit, operating and maintenance personnel quickly become familiar with the WMP and use it more effectively • Programming is done thru the keypad mounted on the face of the enclosure 556023 Technical Specifications Power Supply.....................................................................115 + 15 % VAC, 50/60 Hz; 230 + 15% VAC, 50/90 Hz; 24 + 15% VDC; 12 + 10% VDC. Voltage must be specified when ordering Inputs ...................................................................................................................... Same voltage of WMP III in use Current Consumptions ................................0.1 amp for AC (less external loads); 0.4 amp for DC (less external loads); 0.5 amp 3AG fuse supplied; 115, 230 VAC and 12, 24 VDC External Pump Load .................................................115, 230 VAC or 12, 24 VDC; 2 amp max(4 amp typical inrush), AC; 2 amp AGC fuse supplied; Determined by input power supply Fault Relay ...................................2 isolated, non-fused, double-pole, double-throw form, C contacts, 5 amp resistive Count Rate .............................................................................................. 15 CTS/SEC max @ 50% duty cycle; min. Transient Withstanding Capacity ....................................................... 2000 Volts for 1 millisecond (typical); Joule Max Temperature Range (LCD limited) Ambient ................................................................................................................10º F to 113º F (-21º C to 45º C) Storage ................................................................................................................. -8º F to 140º F (-25º C to 60º C) Time Base ................................................................................................................... Crystal Controller Time Base Weight........................................................................................................................................... 9.3 lbs (4.2 kg) Programming Selections Program Range .......................................................... 2-9999 sec; 1-9999 min.; 1-9999 hrs; 2-9999 stroke counts Monitor Range ........................................................... 1-9999 sec; 1-9999 min.; 1-9998 hrs; 1-9998 stroke counts System Cycle Range ........................................................................................................................1-9999 counts Ordering Information WMPII Maxi-Monitor 556023 115 VAC 556024 230 VAC 556025 24 VDC 563914 Shock mount kit Controllers www.graco.com 99