Views
3 months ago

CTS - Climatic Test Cabinet Type C -40/350

Data leaflet of a CTS - Climatic Test Cabinet Type C -40/350 sold by www.cts-klimaskabe.dk

Dimensions:

Dimensions: Test space capacity 350 l Test space 650 x 720 x 750 mm (W x D x H) Overall dimensions see enclosed layout Weight approx. 600 kg net Data for installation and operation: Nominal voltage Nominal power Nominal current Connection Fuse (on site) 400 V +6/-10 %, 3/N/PE, 50 Hz 7 kW 12 A CEE 16 A 16 A time-lag Protection class IP 22 Power requirement cooling, max. 4,0 kW cooling, stabilized condition 2,0 kW heating, max. 3,9 kW heating, stabilized condition 1,0 kW climate, stabilized condition 3,3 kW humidification water Cooling water: Compressed air: Drain for condensate: consumption max. 1,5 l/h at max. humidification performance demineralized water conductivity max. 10 µS/cm pH-value 6 – 7 water has to be free of algae and pollution not necessary, or see options not necessary, or see options pressureless R ½”, Note: A drain is required by site, also if the option “automatic water replenishment” is ordered Pressure equalisation: on top of the cabinet If there can be any emission from test specimen that will cause certain concentration and therefore unacceptable smell to the installation room, the exhausted air of the pressure compensator can be led out by a customer’s exhaust air system with an open connection. The pressure equalizer must never be closed. C40_350_v2017_eng_.doc 18.01.2018 page 4 of 9 pages Version: 2017

Design: Test space stainless steel V2A, grade 1.4301 Shelf stainless steel V2A, grade 1.4301, 620 mm x 600 mm (W x D) max. load of each shelf 35 kg, max. load in total (max. number of shelves) 100 kg Floor load max. 150 kg/m 2 Air flow Heating/Cooling Climatic system Reservoir for humidification water Casing air inlet via air flow floor with a high air flow rate, air outlet at the rear wall of test space - heating by electrical resistant heaters, made of stainless steel, - mechanical cooling by direct evaporation in heat exchanger - water bath with permanent circulation and automatic water feed from supply tank. - dehumidification via condensation. Convenient filling from the front side galvanized steel, resistant powder coating Colour casing RAL 9006, white-aluminium decorative plates RAL 9007, grey-aluminium Door Refrigerating unit door can be opened completely hinged on left-hand side, one hand operation lockable air cooled, low noise refrigeration unit, continuous performance adjustment via electronic monitoring and control system, environmental friendly refrigerants R 452 A based on the current directives and regulations. Heat dissipation to the stabilized conditions approx. 3,0 kW installation room cooling max. approx. 7,0 kW Sound pressure level in accordance to DIN EN ISO 3744 < 55 dB(A), measured in a distance of 1 metre from front Ambient conditions for operating: temperature: +15°C to +30°C rel. humidity: 20 % to 75 % rel. h. The room must be dry and ventilated. The floor has to be plane. Local laws and standards have to be considered by the customer. C40_350_v2017_eng_.doc 18.01.2018 page 5 of 9 pages Version: 2017

CTS range of Environmental test chambers 2018