Views
5 months ago

Dekton Free Installation Guide

OVERHANGS The following

OVERHANGS The following measurements are recommended for overhang thicknesses: V OVERHANGS FOR WORKTOPS WITHOUT CUT-OUTS 12mm 20mm Full side overhang (1) (2) V ≤ 25 cm V ≤ 50 cm Partial overhang (3) V L ≤ 50 cm; V L ≤ 100 cm; V C ≤ 20 cm V C ≤ 40 cm 1 2 3 V A V ≥V A ≥V L V L V C ≥V C *A ≥ 60 cm; V = Overhang; V L = Long Overhang; V C = Short Overhang Occasional maximum static load = 100 kg OVERHANGS FOR WORKTOPS WITH CUT-OUTS 12mm 20mm Full side overhang (4) (5) V ≤ 25 cm V ≤ 50 cm Partial overhang (6) V L ≤ 50 cm; V L ≤ 100 cm; V C ≤ 20 cm V C ≤ 40 cm 4 5 6 V A V C 1 C 2 C 1 C 2 C 1 C 2 C 3 C 4 ≥V C V C ≥V L V L ≥V V ≥V *A ≥ 60 cm; V = Overhang; V L = Long Overhang; V C = Short Overhang Occasional maximum static load = 100 kg Conditions: (4) (5) C 1 , C 2 ≥ 10 cm; C 1 + C 2 ≥ 35 cm (6) C 1 , C 2 , C 3 , C 4 ≥ 10 cm; C 1 + C 2 ≥ 35 cm; C 3 + C 4 ≥ 35 cm The above table only applies to worktops with one cut-out. For more information, please contact Cosentino ® 10 WORKTOP INSTALLATION MANUAL

WORKTOP EDGES We recommend bevelling the outer edges of worktops to improve their resistance to impact and to avoid possible cuts from sharp edges. The greater the bevel, the greater its resistance to impact. The minimum bevel is of 1 mm when it is hidden or not exposed (for example, against a wall), and 3 mm when exposed. However, it is common to cut bevels greater than those mentioned above despite being technically complex. Dekton ® recommends using the following edges for worktops: 3mm JOINS. SEAMS AND BACKSPLASHES Due to the irregularities of the wall and possible structural movements of the building, we recommended leaving a perimeter expansion joint of 3mm on the worktop. These visible spaces should be filled with silicone. The seam between the backsplash and worktop should be sealed with a thread of silicone. MITRED EDGE STRAIGHT EDGE 3mm 3mm 1mm 3mm 3mm 1mm 3mm POLISHED EDGE 3mm 1/43mm Edge NON-POLISHED EDGE 1mm Wall 1mm 1mm 3mm 1mm 3mm 3mm These edge type reduce the 1mm likelihood of chipping and breakage during use. 1mm 3 mm separation Silicone filling 11

installation guide duct cover - K-Flex USA
installation guide duct cover - K-Flex USA
Sensor Installation Manual - Kinetic
Armarac Installation Guide
Installation Guide - Smarthome
Installation Manual - Noctua.at
Installation Manual - Noctua.at
Proglaze ETA Installation Instructions - Tremco Sealants
xPoint installation and setup guide
NSVI Installation Guide - IXL Masonry
Installation Guide ECS5510-48S 48-Port 10G Ethernet ... - Edge-Core
P-DR Installation Guide - 20/20 Imaging
Marley Rainwater Design & Installation Guide - BHL.co.uk
ActiveSmart™ User Guide & Installation ... - Fisher & Paykel
M-Series Installation Guide - Flir Systems
CPU Module Installation Guide - Dynojet Research
Installation guide: LILIN LR6122EX3.6 - Network Webcams
Installation guide
installation guide & owners manual - American Beauty Equipment
Installation Guide - DATAQ Instruments
Network Installation Guide - Xactware
Vivotek IP8151P Fixed Network Camera Installation Guide - Use-IP