Laboratory Equipment

crimesciencesinc.

CYANOACRYLATE FUMING CHAMBERS AND FILTERS

The Cyanoacrylate Fuming Chamber is used to develop latent prints from

non-porous surfaces in a controlled and safe environment. The ductless

design allows immediate use. Simply plug-in and go.

Cyanoacrylate is placed inside the chamber while evidence is easily posioned

using the adjustable hanging rods. Star ng the cycle triggers the

automated system to control the hotplate, humidity, door lock, internal

circula on fan, and purge cycle.

Its recirculatory design makes the unit ‘ready to use' with no duc ng required

for its opera on or setup. The Cyanoacrylate vapours are filtered

by a special carbon filter. This ensures that no dangerous substances are

exhausted in to the atmosphere surrounding the laboratory. Its ductless

construc on also allows the unit to be easily moved and transported.

The easy to use control displays all parameters of the processing cycle.

Adjustments to the presets can be quickly performed. Display features

include: Hot plate, Humidity, Temperature, Circula on fan, Cycle me,

Lights, Door posi on with lock alarm, Filter condi on, Purge cycle with emergency stop.

FC-CA-60-01

External Dimensions(w x d x h) : 60cm x 60cm x 76cm

Internal Dimensions (w x d x h) : 58cm x 58cm x 70cm

Airflow (m3/hr): 175

Prefilter (efficiencies superior to 99.6%): 1

Main Filter 5kg: 1

Electrical Supply: Single Phase 230v, 50Hz

Noise (dBA) :


FC-CA-150-01

External Dimensions( w x d x h) : 152cm x 75cm x 155cm

Internal Dimensions (w x d x h): 141cm x 67cm x 147cm

Airflow (m3/hr): 250

Prefilter (efficiencies superior to 99.6%): 1

Main Filter 5kg: 1

Electrical Supply: Single Phase 230v, 50Hz

Noise (dBA) :


Downflow Worksta ons (DWS) & Filters

The DWS is a compact bench mounted Downflow Worksta on. It is

ideal for operators handling harmful substances that require unrestricted

access to their work area. Simply plug-in for immediate

use. - Harmful fumes pass through the units filters, re-circula ng

clean air back into the laboratory. - There is no need for expensive

duc ng to be installed due to the units re-circulatory airflow. - Its

ductless construc on allows for the unit to be easily moved. - Carbon

and HEPA filters are available to suit most laboratory applicaons.

- The stainless steel tray is removable for easy cleaning. - The

safety alarm will alert the operator if face velocity falls below 0.3

M/Sec.

FC-DWS-60-01

Dimensions (w x d x h): 62cm x 58cm x 80 cm Main Filter Weight: 8

Airflow (m 3/hr): 248 Working Height: 40 cm Prefilter (efficiencies

superior to 99.6%): 1 Face Velocity (m3/sec): >0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):

0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):

0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):


DUCTLESS FUME HOODS

FC 10 - FC 30 Benchtop Fume Cupboards & Filters

A range of 5 benchtop Fume Cupboards suitable

for a broad range of professional laboratory applica

ons and requirements. Their ductless construcon

means they are ready to plugin and use.

- Harmful fumes pass through the units filters, recircula

ng clean air back into the laboratory.

- There is no need for expensive duc ng to be installed due to the units re-circulatory airflow.

- Designed by leading fume filtra on specialist, John Haugh.

- The safety alarm will alert the operator if face velocity falls below 0.3 M/Sec.

- Its ductless construc on allows for the unit to be easily moved.

- All Fume Cupboards are delivered in 2 easy to assemble sec ons.

- Internal ligh ng illuminates the work surface. - Carbon and HEPA filters are available to suit most laboratory applica ons.

- Cable pass through ports allow electrical cords to enter the work zone.

- Clear acrylic panels allow for tri-direc onal viewing.

- The acrylic construc on also allows for easy cleaning.

-Electronic monitoring systems are available as an op on.

FC-FC-10 Dimensions (w x d x h): 75cm x 60cm x 121cm Working Base Area: 70 cm x 65cm Main Filter 12kg (qty): 1 Safety Filter 5kg

(qty):1 Airflow (m 3/hr): 246 Prefilter (efficiencies superior to 99.6%): 1 Noise (dBA):0.5 Electrical Supply:

Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single

Phase, 230V, 50Hz Noise (dBA):


FC5 Benchtop Fume Cupboards & Filters

The Economy FC5 is a compact bench mounted Fume Cupboard ideal for laboratories where space is

limited or where only small volumes of harmful substances are handled. Simply plug-in for immediate

use.

- Harmful fumes pass through the units filters, re-circula ng clean air back into the laboratory.

- There is no need for expensive duc ng to be installed due to the units recirculatory airflow.

- The safety alarm will alert the operator if face velocity falls below 0.3 M/Sec.

- Its ductless construc on allows for the unit to be easily moved.

- Carbon and HEPA filters are available to suit most laboratory applica ons.

- Internal ligh ng illuminates the work surface.

- Clear Acrylic panels allow for ‘all-round' viewing.

- The Acrylic construc on also allows for easy cleaning.

FC-FC5-60-01

Dimensions (w x d x h): 60cm x 67cm x 90cm

Working Base Area: 58 cm x 52 cm

Main Filter 12kg (qty): 1

Airflow (m 3/hr): 200

Prefilter (efficiencies superior to 99.6%): 1

Face Velocity (m3/sec): >0.5

Electrical Supply: Single Phase, 230V, 50Hz

Noise (dBA): 55

Ligh ng (wa s): 15

Switches: Mains On/OFF

Monitoring: Low Airflow Indicator

Fan: Low Noise Centrifugal

Cabinet Construc on: Epoxy coated mild steel frame and head

unit

Panel Construc on: Clear acrylic

FC-FC5-90-01

Dimensions (w x d x h): 91.5cm x 67cm x 90cm

Working Base Area: 89.5 cm x 52 cm

Main Filter 12kg (qty): 1

Airflow (m 3/hr): 200

Prefilter (efficiencies superior to 99.6%): 1

Face Velocity (m3/sec): >0.5

Electrical Supply: Single Phase, 230V, 50Hz

Noise (dBA): 55

Ligh ng (wa s): 15

Switches: Mains On/OFF

Monitoring: Low Airflow Indicator

Fan: Low Noise Centrifugal

Cabinet Construc on: Epoxy coated mild steel frame and head

unit

Panel Construc on: Clear acrylic

FC-FC5-120-01

Dimensions (w x d x h): 120cm x 67cm x 90cm

Working Base Area: 119 cm x 52 cm

Main Filter 12kg (qty): 1

Airflow (m 3/hr): 400

Prefilter (efficiencies superior to 99.6%): 2

Face Velocity (m3/sec): >0.5

Electrical Supply: Single Phase, 230V, 50Hz

Noise (dBA):


Mobile Ductless Fume Cupboard

The Graduate is a mobile Fume Cupboard with all-round viewing windows. This makes it ideal for

demonstra on purposes and laboratories requiring a unit that is easily manoeuvred. Simply plug-in

for immediate use. Harmful fumes pass through the units filters, re-circula ng clean air back into the

laboratory. There is no need for expensive duc ng to be installed due to the units recirculatory airflow.

The safety alarm will alert the operator if face velocity falls below 0.5 M/Sec. Its ductless construc

on allows for the unit to be easily moved. Carbon and HEPA filters are available to suit most

laboratory applica ons. Pass through ports and quick release hose connectors for Gas, Water and

Waste. Designed by leading fume filtra on specialist, John Haugh. Internal ligh ng illuminates the

work surface. Clear acrylic panels allows for ‘all-round’ viewing. The acrylic construc on also allows

for easy cleaning.

FC-GRD-001-01 Dimensions (w x d x h): 100cm x 74cm x 197cm Main Filter 12kg (qty): 1 Airflow (m 3/hr): 250 Prefilter (efficiencies

superior to 99.6%): 1 Noise (dBA):0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):


EVIDENCE DRYING CABINETS

The Forensic Evidence Cabinet is used for drying

and storing evidence recovered from a crime scene.

The cabinet will ensure containment of

fumes, odours and par culates, whilst also minimizing

the risk of cross contamina on.

Controls are located at front of the cabinet and

include:

Humidity sensor to inform the operator when the

evidence is dry and ready to remove.

Security tags and Key Locks on main access door.

Low Airflow Alarm for blocked filters.

Op onal heater in top sec on to maintain ambient

temperature in cold loca ons.

Its recirculatory design makes the unit ‘ready to use' with no duc ng required for its opera on or setup. Air entering into the top

of the cabinet is first passed through an inlet pre-filter and then through a HEPA par culate filter to ensure it is clean and sterile.

The sterile air then passes downwards through the cabinet in an laminar follow pa ern ensuring evidence is dried under sterile air

condi ons. Vapours, odours and par culates given from drying evidence are filtered by both special carbon and HEPA filters located

in the base unit. This ensures that no dangerous substances are exhausted in to the atmosphere surrounding the laboratory. Its

ductless construc on also allows the unit to be easily moved and transported.

Corrosion proof interior design increases opera onal life, with the use of reinforced plas cs that are resistant to corrosion from

various liquids and fumes.

Each cabinet includes a complete plumbing package that makes cleaning the cabinet easy. The spray hose is kept outside the

working compartment at all mes to prevent the chance of cross contamina on. A drain outlet with flexible hose is provided to

allow waste water to be removed from the cabinet. The space inside the cabinet can be used to provide full length hanging space

and with removable shelves for storage of smaller items.

Op onal accessories include: Ligh ng, Starter Kit, Pre filters


FINGERPRINT DEVELOPMENT

Downflow Worksta ons & Filters

The DWS is a compact bench mounted

Downflow Worksta on. It is ideal for operators

handling harmful substances that

require unrestricted access to their work

area. Simply plug-in for immediate use.

- Harmful fumes pass through the units

filters, recircula ng clean air back into the

laboratory.

- There is no need for expensive duc ng to

be installed due to the units re-circulatory

airflow.

- Its ductless construc on allows for the unit to be easily moved.

- Carbon and HEPA filters are available to suit most laboratory applica ons.

- The stainless steel tray is removable for easy cleaning.

- The safety alarm will alert the operator if face velocity falls below 0.3 M/Sec.

FC-DWS-60-01 Dimensions (w x d x h): 62cm x 58cm x 80 cm Main Filter Weight: 8 Airflow (m 3/hr): 248 Working Height: 40 cm

Prefilter (efficiencies superior to 99.6%): 1 Face Velocity (m3/sec): >0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):


Downdra Tables

Freestanding Downdra Tables are designed

to give operator protec on while allowing

complete, easy and open access to the working

area. Harmful fumes and vapours are

drawn downward through the stainless steel

worksurface to the units filters. Clean air is

then re-circulated back into the laboratory.

- The safety alarm will alert the operator if

worksurface face velocity falls below 0.3 M/

Sec.

- There is no need for expensive duc ng to be

installed due to the units recirculatory airflow.

- Designed by leading fume filtra on specialist, John Haugh.

- Carbon and HEPA filters are available to suit most laboratory applica ons.

- The polypropylene and stainless steel construc on also allows for easy cleaning.

- Product manufactured in ISO 9001 quality controlled facili es

FC-FDT-100-01 Dimensions (w x d x h): 100cm x 70cm x 90cm Working Base Area: 80cm x 45cm Main Filter 12kg (qty): 1 Op onal

Safety Filter 4kg (qty): 1 Airflow (m 3/hr): 250 Sink & Tap: N/A Prefilter (efficiencies superior to 99.6%): 1 Face Velocity (m3/sec):

>0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):


Dye Staining Benches & Filters

Dye Staining Benches are designed to give operator protec on from

the Ethanol dye used during the forensic process of developing latent

finger prints from non-porous surfaces. The Polypropylene sink, dye

storage tank, water facili es and open work surface provide the op -

mum environment for the efficient processing of such prints.

- There is no need for expensive duc ng to be installed due to the

units re-circulatory airflow.

- The polypropylene and stainless steel construc on also allows for

easy cleaning.

- The worksurfaces will not rust or corrode when in contact with water

and chemicals.

- Carbon and HEPA filters are available to suit most laboratory applica ons.

- The harmful fumes and vapours are drawn downward through the worksurface to the units filters. Clean air is then re-circulated

back into the laboratory.

-The safety alarm will alert the operator if work surface face velocity falls below 0.3 M/Sec.

FC-DSB-120-01 Dimensions (w x d x h): 120cm x 70cm x 135cm Working Base Area: 85cm x 59 cm Main Filter 12kg (qty): 2 Op onal

Safety Filter 4kg (qty): 2 Airflow (m 3/hr): 500 Prefilter (efficiencies superior to 99.6%): 2 Sink, Cold Tap & Hand Shower: Yes Face

Velocity (m3/sec): >0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise (dBA):


Inset Downdra Tables

Inset Downdra Tables are designed to give operator

protec on while allowing complete, easy and open

access to the working area. Harmful fumes and vapours

are drawn downward through the stainless steel worksurface

to the units filters. Clean air is then recirculated

back into the laboratory. The inset design fits

flush in to an exis ng bench top. Ideal to save space or

use when a freestanding bench is not suitable. There is

no need for expensive duc ng to be installed due to

the units recirculatory airflow. The safety alarm will alert the operator if worksurface face velocity falls below 0.3 M/Sec. Carbon

and HEPA filters are available to suit most laboratory applica ons. The polypropylene and stainless steel construc on also allows

for easy cleaning. The worksurfaces will not rust or corrode when in contact with water and chemicals.

FC-IDT-60-01 Dimensions (w x d x h): 60cm x 45cm x 40cm Working Base Area:55cm x 40cm Main Filter 12kg (qty): 1 Airflow (m 3/

hr): 200 Prefilter (efficiencies superior to 99.6%): 1 Face Velocity (m3/sec): >0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise

(dBA): 55 Switches: Mains On/OFF Monitoring: Low Airflow Indicator Fan: Low Noise Centrifugal Construc on: White polypropylene

with perforated stainless steel work surface

FC-IDT-90-01 Dimensions (w x d x h): 91.5cm x 45cm x 40cm Working Base Area:86.5cm x 40cm Main Filter 12kg (qty): 1 Airflow (m

3/hr): 200 Prefilter (efficiencies superior to 99.6%): 1 Face Velocity (m3/sec): >0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise

(dBA): 0.5 Electrical Supply: Single Phase, 230V, 50Hz Noise

(dBA):

More magazines by this user