Views
8 months ago

V27 Software Guide Pulpmatic Ultima Eco Uno Incomatic V1.7

Machine start options

Machine start options V17 to current version Advance machine start options listed below start on V17. Older versions have restricted options. Hands Free Start Options 02 = Foot cup to open the lid, I.R hand sensor to close the lid and start the cycle. If hand sensor is not activated the lid will close after the adjustable time delay (value adjustable in Auto close delay parameter) default set to 60 seconds. Auto lid close buzzer sound enabled 34 = Foot cup to open the lid, I.R hand sensor to close the lid and start the cycle. If hand sensor is not activated the lid will close after the adjustable time delay (value changeable in Auto close delay parameter) default set to 60 seconds. Auto lid close buzzer sound disabled 00 = Foot cup to open the lid, I.R hand sensor to close the lid and start the cycle. If hand sensor is not activated the lid will not automatically close. Foot Cup Start Options 03 = Selecting this option will enable starting a machine cycle from the foot cup sensor. Foot cup to open the lid, second footcup activation to start the cycle. If the foot cup is not activated the lid will close after the adjustable time delay (value adjustable in Auto close delay parameter) default set to 60 seconds. Auto lid close buzzer sound enabled. IR sensor can still be used to activate the machine if required. 35 = Selecting this option will enable starting a machine cycle from the foot cup sensor. Foot cup to open the lid, second footcup activation to start the cycle. If the foot cup is not activated the lid will close after the adjustable time delay (value adjustable in Auto close delay parameter) default set to 60 seconds. Auto lid close buzzer sound disabled. IR sensor can still be used to activate the machine if required. 01 = Selecting this option will enable starting a machine cycle from the foot cup sensor. Foot cup to open the lid, second footcup activation to start the cycle. If the Footcup is not activated the lid will not automatically close. IR sensor can still be used to activate the machine if required. Fully Automatic Start Options 10 = Fully automatic start sequence from a single activation of the foot cup sensor. The lid will open after the pre-set time (Lid pre-open delay parameter) and the lid will close after the adjustable time delay (value changeable in Auto close delay parameter) which is set to the default of 60 seconds. Auto lid close buzzer sound enabled Copyright © 2017 DDC Dolphin Ltd. Page 14 of 47 February 18 SGPv27 – V1.7

42 = Fully automatic start sequence from a single activation of the foot cup sensor. The lid will open after the pre-set time (Lid pre-open delay parameter) and the lid will close after the adjustable time delay (value changeable in Auto close delay parameter) which is set to the default of 60 seconds. Auto lid close buzzer sound disabled Please note the BOLD highlighted parameters may need to be adjusted to optimise the selected start option Machine start options V11 to V15 + (V15.2 Eco Only!) 00 = Selecting this option will allow the machine to operate from the I.R hand start only 01 = Selecting this option will enable starting a machine cycle from the foot cup sensor. By placing your foot into the foot cup sensor at the base of the machine will automatically put the machine into a cycle 02 = Selecting this option will allow the machine to operate from the I.R hand start and the lid will close after 60 seconds. Buzzer sound enabled 03 = Selecting this option will enable starting a machine cycle from the foot cup sensor. By placing your foot into the foot cup sensor at the base of the machine will automatically put the machine into a cycle. The lid close after 60 seconds. Buzzer sound enabled Auto water pump interval timer This setting permits the machine to operate the water pump for a defined period of time This setting will determine how long after the last cycle the auto pump run will occur. The timer starts at the end of the last cycle, if the machine is operated before interval time, the interval timer will reset. If the machine is not put into cycle the interval timer will activate the water pump for a defined period of time (duration set by Pump run duration). At the end of the pump run a small amount of chemical is dosed into the water (Auto pump chemical dose) to maintain the disinfected surface treatment. Setting the water pump to a short interval i.e. 1hr will consume more chemical and should be reserved for locations with problematic drains. DO NOT USE EVEN NUMBERS for this setting as this will run a full machine cycle. DDC Dolphin Ltd strongly recommends this feature is not activated. Copyright © 2017 DDC Dolphin Ltd. Page 15 of 47 February 18 SGPv27 – V1.7

ULTIMA™ - Medical Graphics Corporation
A Leader's Guide to Agile Business - Rally Software
Medical Office Software Guide
Estimation of Source Parameters for Hazard Releases
SNC-DH110T - Sony Professional Solutions Asia Pacific
WinAlign® Software
License Administration Guide - Sonnet Software
Agile Development, DevOps and achieving ... - Rally Software
Geovision NVR Software Feature Guide - Use-IP
Product datasheet: Sony SNC-DH240T - Network Webcams
Ultima SmartBelt User Guide
EtherLogic Ultima Controller - Industrial Control Links
Distributed by The Ultima CCM provides real solutions for: Bias Flow ...