Views
5 months ago

V27 Software Guide Pulpmatic Ultima Eco Uno Incomatic V1.7

Value 0 1 3 5 7 9 11 13

Value 0 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 Interval timer OFF 24 Hours 1 minute (diagnostic) 1 Hour 2 Hours 3 Hours 4 Hours 5 Hours 6 Hours 7 Hours 8 Hours 9 Hours 10 Hours 11 Hours 12 Hours 13 Hours 14 Hours 15 Hours 16 Hours 17 Hours 18 Hours 19 Hours 20 Hours 21 Hours 22 Hours 23 Hours Auto water duration in seconds This parameter determines how long the water pump will operate if parameter Pump run interval is set to any of the ODD number listed above. If Pump run interval is set to zero parameter Pump run duration will have no effect. This parameter value is the time in seconds the auto pump feature will run for. The Uno water pump has a typical flow rate of 9.7ltrs per minute; each 10 seconds of pump run will provide 1.6ltrs of water. The Ultima water pump has a typical flow rate of 14.2ltrs per minute; each 10 seconds of pump run will provide 1.6ltrs of water. The Incomatic water pump has a typical flow rate of 18.75ltrs per minute; each 10 seconds of pump run will provide 3.125ltrs of water. The Pulpmatic Plus water pump has a typical flow rate of 14.2ltrs per minute; each 10 seconds of pump run will provide 1.6ltrs of water. Copyright © 2017 DDC Dolphin Ltd. Page 16 of 47 February 18 SGPv27 – V1.7

Lid open delay in seconds This parameter will enable a delay of the lid opening when the foot cup is activated. This delay is intended to ensure the operator has time to listen to the recorded message when the optional speaker system is fitted. Caution should be used when using this function, staff intuitively expect the lid to open immediately; staff may become distracted believing they have not operated the foot cup correctly. If required a delay can be enabled by increasing the parameter from 0 to 20 seconds, a delay longer than 5 seconds is not recommended. Lid open duration in seconds When the foot cup is activated the lid will open, once it reaches the fully open position it will stay open for the time set in this parameter. If activated the IR hand sensor will eliminate the lid open timer, the lid will close and the cycle will commence. At the end of the lid open timer the machine emits a warning bleep as the auto close sequence starts (warning bleep can be disabled in Machine start options). The machine will then either go into self-start cycle (Machine start options – auto start) or do nothing if the start option is set to IR sensor only (Machine start options). When using the auto-start functions; trials have indicated a close delay of 10 – 15 seconds appears to work well. The user should be given sufficient time to load and check the contents for non maceratable items. This time delay must also permit time for the daily cleaning of the lid seal area. Operation of the foot cup will re-open the lid. (This feature is deactivated once the machine starts a cycle). Auto water pump chemical dose in seconds Parameter Pump run interval is used to determine how often the auto water pump run should occur, if Pump run interval = 0 the auto pump run is de-activated and Auto pump chemical dose is not required. If Pump run interval is activated It is essential the last few seconds of water should contain EcoCleanse+ sanitiser. This will maintain the disinfection of the internal surfaces of the machine, running only water only may permit natural bacterial present in the water to grow. Auto pump chemical dose determines the duration of the chemical dosing at the end of the auto pump sequence (this is not the dosing time for the main cutting cycle). The Uno chemical pump delivers more fluid per second than the Ultima hence the difference in recommended settings. Copyright © 2017 DDC Dolphin Ltd. Page 17 of 47 February 18 SGPv27 – V1.7

A Leader's Guide to Agile Business - Rally Software
Medical Office Software Guide
WinAlign® Software
software validation - Pharsight Corporation
License Administration Guide - Sonnet Software
Agile Development, DevOps and achieving ... - Rally Software
TerraExplorer Quick Start Guide - Skyline Software Systems
Geovision NVR Software Feature Guide - Use-IP
Product datasheet: Sony SNC-DH240T - Network Webcams
SNC-CH220 - Sony Professional Solutions Asia Pacific
Camera IP HD de tip bullet Sony SNC-CH160 - GTO Security ...
EtherLogic Ultima Controller - Industrial Control Links
Polycom UC Software Administrators' Guide
Polycom UC Software Administrators' Guide - 4.1.0
JideFX Common Layer Developer Guide - JIDE Software