PACKAGING MegaSıva İ

PACKAGING MegaSıva İ is delivered in net 25 kg kraft bags, which are stowed in 54 pcs. on a 80 cm x 100 cm palette (1350 kg). SHELF LIFE The shelf life of the product is 12 months when stored within non tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment. STORAGE CONDITIONS The product should be stored within non tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment. It should not be exposed to direct sunlight. The container of the product should be closed firmly when not used. SAFETY PRECAUTIONS Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application. 105

MegaSıva K Cement Based, Manually Applied Roughcast PRODUCT DESCRIPTION Cement based, manually applied roughcast with filling material in appropriate granulometry. AREAS OF USE MegaSıva K is applied manually on the walls and ceilings of indoors and outdoors spaces, on prime coated gas concrete, brick, prime coated concrete and briquette walls. PRODUCT ADVANTAGES • Ensuring high bonding to the surface, the product does not cause spalling and poses high bonding strength. • Being a high performance product, it does not cause contractions. • Applied easily and rapidly. PERFORMANCE Dry bulk density 1.65 ± 0.1 gr/cm 3 TS EN 1015 - 10 Compressive strength CS III TS EN 1015 - 11 Bonding strength > 0.2 N/mm 2 TS EN 1015 - 12 Capillary water absorption coefficient W 0 TS EN 1015 - 18 Water vapor permeability µ < 15 TS EN 1015 - 19 Air content % 6 ± 0.5 TS EN 1015 - 7 Workability time > 3 hours (at 20 ± 5°C temperature and minimum 95 TS EN 1015 - 9 % relative humidity) Reaction to fire A1 TS EN 13501 - 1 The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C temperature and 50% ± 5 relative humidity conditions. The values provided as per the table may vary depending on the surface and ambient conditions. REFERENCE STANDARDS Certifications/Standards TS EN 998 - 1 (GP) Ministry of Public Works and Settlement Item No. Ministry of Public Works and Settlement Item No.: 04.482 QUALITY CERTIFICATES Conformant to TS EN 998 - 1. CE APPLICATION PROCEDURE Application Surfaces Indoors and Outdoors Walls; - Gas concrete (MegaFilm primer applied) - Concrete (MegaFilm or MegaFilm BB primer applied) - Briquette - Brick Ceilings; - Concrete (MegaFilm or MegaFilm BB primer applied) Surface Preparation • The application surface should be dry, clean, sound and dust-free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface. • The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 24 hours in advance. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred. • The application surfaces should be moisturized with water, where necessary. • Upon the completion of the surface cleaning, MegaFilm primer should be applied in a single coat with a brush and be left to dry for 1 to 2 hours in order to enhance the bonding strength and stabilize the surface absorption. • Gas concrete surfaces should, prior to the application of the product, be applied MegaFilm primer and the water absorption of the surfaces should so be reduced. • Exposed concrete surfaces should be applied MegaFilm BB exposed concrete primer in single coat and be left to dry for minimum 3 hours prior to the application of the adhesive mortar in order to enhance the adhesion strength. Application Methods • The application thickness should range between 1.0 cm and 2.5 cm. In the cases where the application thickness is to exceed 2.5 cm, an additional coat of maximum 2 cm thickness should be applied upon the sufficient hardening of the primary coat. • The product should be applied with a steel trowel, whereupon the surface should be smoothened with a gauge stick. • Once plaster dewaters and is sufficiently hardened following the application, the surface should be processed with a trowel and final finishing touches should be made with a moist sponge. Application Recommendations • The surface should be moisturized intermittently for a period 7 days following the application in order to enhance the endurance of the plaster. • Plaster profiles should be employed on the corners in order to ensure a better quality result and high level of efficiency. • The product should not be applied to gypsum surfaces. • MegaLatex may be employed in order to enhance the performance of the product. • The product should, once mixed, be used before the expiration of its pot life. Any product, the pot life of which has expired, should not be used during the application. • Any such foreign substance as lime, cement or plaster should not be added to the mortar prepared. • Any extra water should not be added to the mixture. • The product should not be applied on unsound surfaces. The soundness and the load bearing capacity of old surfaces should be checked prior to adhesion. • The surface should be preserved from air currents and water contact during and after the application. • The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing. • Due care should be taken to ensure that the material is not exposed to direct sunlight in hot weather conditions, and the product should be mixed with cold water. • The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance. • The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours. • Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595) Surface and Ambient Temperature The surface and ambient temperature should be between +5°C and +30°C whilst at application. Application Limits Useful time for prepared mortar - Pot life Plaster surface smoothing time Through dry time The foregoing values represent the results of the laboratory tests conducted at 23 ± 2°C temperature and 50% ± 5 relative humidity conditions. The values provided as per the table may vary depending on the surface and ambient conditions. APPLICATION INSTRUCTIONS Mixing Ratio The product should be mixed with water, weighing equal to 20 - 22 % of the product. (5.0 - 5.5 liters of water for a 25 kg package) Mixing Equipment • Low speed electrical mixer (400 cycles/min.) • Special tip stirring equipment Mixing Period The product should be stirred with a low speed mixer until any dry dust and globs are eliminated. The mortar should, then, be stirred once again for 1 to 2 minutes after being had settled for 3 to 4 minutes following preparation. Application Equipment • Steel trowel • Smoothing trowel • Sponge Equipment Cleaning The equipment used should be cleaned with water following the application before the mortar dries. TECHNICAL PROPERTIES Chemical Structure: Cement based roughcast mortar Dry Density: 1.65 ± 0.1 gr/cm 3 Mortar Density: 1.85 ± 0.1 gr/cm 3 Grain Size: ≤ 1800 µm Coat Thickness: Maximum 1.0 cm - 2.5 cm (single coat) Color: Gray Maximum 1 hour Maximum 30 minutes Minimum 2 days CONSUMPTION Recommended consumption amounts for application in roughly 1 cm thickness on 1 m 2 surface; 106

Paver Reneu Bro 8.5x11 - Vexcon Chemicals
Ground Gas Barriers Brochure Download - Triton Chemicals
Machines, Equipments and Systems for Tunnel Construction
Health and Safety Data Sheets for Cements and Cement Products
Click here for PDF Guide - Womersleys
BASF CC Brochure - BASF Construction Chemicals Pacific
Epoxy Coatings Brochure - Euclid Chemical Co
AGC Chemicals Product Range - AGCCE
GENERAL PURPOSE cEmENt - Lafarge in South Africa
Grand Housing Development Program Volume III - Gtz
manual for supervisors and project staff - International Recovery ...
Soak the buildup, let EZEE Clean work awhile, then ... - IMER USA.
Durable Connections - BASF Construction Chemicals Pacific
Chemicals & Janitorial - HRS Janitorial Service & Supplies
Using Chemical Products in HVAC Systems: - NADCA
HeatWave 110, 120, 135, 155 Heat Only - prior to ... - AquaCal
Your reliable partner in the tool welding construction - UTP ...
conform column formers for circular columns construction formwork ...
Challenges in Catalysis for Pharmaceuticals and Fine Chemicals 3
The complete range for quality leather - Performance Chemicals ...
Bridge and Road Repair Products - Best Materials