Mantotherm EPS Thermal Insulation Panel<br />
Expanded Polystyrene Panel With High Pressure Resistance<br />
PRODUCT DESCRIPTION<br />
Expanded polystyrene panel with high pressure resistance, used for the thermal insulation of<br />
walls, columns and girders.<br />
AREAS OF USE<br />
Mantotherm EPS Thermal Insulation Panel is used as heat insulation material for the<br />
walls, terraces, floors and basements of buildings.<br />
PRODUCT ADVANTAGES<br />
• Highly resistant to pressure.<br />
• Preserves the buildings from the outer atmospheric impacts, prevents corrosion and<br />
elongates the service life of buildings.<br />
• Capable of successfully bearing the short- and long-term mechanical charges, which may<br />
occur in a building under normal conditions.<br />
• Resistant to impacts.<br />
• Has an infinite economic life. The insulating nature of the product does not change in time.<br />
• Poses low thermal conductivity.<br />
• Does not lose its thickness and endures through the time.<br />
• Very lightweight, easy to carry.<br />
• Easy to application.<br />
• Environmentally friendly.<br />
PERFORMANCE<br />
Length tolerance<br />
± 2 mm<br />
Width tolerance<br />
± 2 mm<br />
TS EN 822<br />
Thickness tolerance ± 1 mm TS EN 823<br />
Deviation from squareness ± 2 mm/m TS EN 824<br />
Planarity tolerance ± 5 mm TS EN 825<br />
Visual density 16 kg/m 3 TS EN 1602<br />
Dimensional stability ± % 0.2 TS EN 1603<br />
Compression strength in 10 % deformation 70 kPa TS EN 826<br />
λ (Thermal Conductivity Coefficient) 0.038 W/mK TS EN 12667<br />
Bending strength 115 kPa TS EN 12089<br />
Long term water absorption by partial<br />
immersion<br />
≤ 0.5 kg/m 2 TS EN 12087<br />
Long term water absorption by total<br />
immersion<br />
≤ % 3 TS EN 12087<br />
Tensile strength perpendicular to surface > 100 kPa TS EN 1607<br />
Fire class E TS EN 13501-1<br />
The foregoing values represent the results of the laboratory tests. The values provided as per<br />
the table may vary depending on the surface and ambient conditions.<br />
REFERENCE STANDARDS<br />
Certifications/Standards<br />
TS EN 13163<br />
TS EN 13499<br />
ETAG 004<br />
QUALITY CERTIFICATES<br />
TSE<br />
CE<br />
Conformant to ETAG 004.<br />
APPLICATION PROCEDURE<br />
Application Surfaces<br />
Indoors Walls;<br />
- Finishing coat applied surfaces<br />
Outdoors Walls;<br />
- Roughcast applied surfaces<br />
Surface Preparation<br />
• The application surface should be dry, clean, sound and dust-free, and should have been<br />
cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as<br />
mortar and cement residues should be scraped from the application surface.<br />
• The old plaster coat, blistering and cracks on the facades should be scraped, be repaired<br />
with MegaTamir İ or MegaTamir K, whereby a sound surface should be obtained.<br />
• In the case of bevels in excess of 2 cm on the surface; they should be repaired with<br />
MegaTamir İ or MegaTamir K before insulation application.<br />
• The surface to be insulated should not be moist, and the flooring trowel coating and<br />
internal and external wall plasters should have dried.<br />
• There should not be any moisture in progress upward on the surface, the waterproofing<br />
should be completed as necessary and should have risen 30 cm above the ground soil.<br />
• The insulation application should be initiated minimum 4 weeks after the application of<br />
roughcast.<br />
• The rain gutters, cabling elements and the like on the façade should be placed over the<br />
system and be deployed in some 6 to 7 cm distance to the system.<br />
Application Methods<br />
• Mantotherm EPS Thermal Insulation Panel, the reserve side of should have been<br />
applied Mantotherm Adhesive Mortar, should be firmly placed on the sub-basement<br />
profile.<br />
• In order for Mantotherm EPS Thermal Insulation Panel to thoroughly contact the wall<br />
145<br />
and to ensure the smoothness of the surface, the panel should be slipped slightly and<br />
adhered to the wall, be gauged and linaged.<br />
• Mantotherm EPS Thermal Insulation Panel should be furnished in tusk tenon fashion.<br />
The tusk tenon should be continued also in the corner joint spots of the building.<br />
• Any unintentional gaps between any two Mantotherm EPS Thermal Insulation Panel<br />
should strictly be filled with pieces to be cut from the same material. Due care must be taken<br />
to ensure that the adhesive does not overflow at the edges, where panels join, any overflowing<br />
adhesive should be cleaned and the panel edges should be ensured to be clean.<br />
• The corners of the such gaps on the surface as window gaps and door gaps should be<br />
aligned with the panel joints, the Thermal Insulation Panels should be placed as a whole on<br />
the corners, screw threads should be cut and be sized for the gaps. Hence will be eliminated<br />
the risk of cracks on the corners.<br />
• Mechanical fixation on the surface of the Thermal Insulation Panels in addition to chemical<br />
adhesion is of utmost importance for long-lasting performance. Minimum 24 hours after the<br />
adhesion of the Thermal Insulation Panels, the dowelling should be performed with thermal<br />
insulation panel dowels Mantotherm Thermal Insulation Panel Dowels. Appropriate and<br />
suitable dowels should be selected with due consideration of the insulating material employed<br />
and the surface characteristics.<br />
Application Recommendations<br />
• The product should not be applied to such surfaces, which are exposed to risk of freezing<br />
within the next 24 hours, which are frozen or the frost of which is thawing.<br />
• Due care should be given to prevent the exposure of the material to direct sunlight in hot<br />
weather conditions.<br />
• The product should not be applied on extremely windy weather conditions or on hot<br />
surfaces, which are exposed to direct sunlight; and in the cases, where application is<br />
imperative under such conditions, the environment and the surface should be prepared for<br />
application in advance.<br />
• The product should not be applied in rainy weather conditions, and the application surface<br />
should be preserved from rain for a period of 24 hours.<br />
• Refer to our technical support hotline for recommendation on different surface applications.<br />
(PHONE: 444 4 595)<br />
Surface and Ambient Temperature<br />
The surface and ambient temperature should be between +5°C and +30°C whilst at<br />
application.<br />
APPLICATION INSTRUCTIONS<br />
Application Equipment<br />
• Steel notched trowel (for EPS adhered by dredging)<br />
• Steel trowel<br />
Equipment Cleaning<br />
The equipment used should be cleaned with water following the application before the<br />
mortar dries.<br />
TECHNICAL PROPERTIES<br />
Chemical Structure: Expanded polystyrene panel<br />
Color: White<br />
CONSUMPTION<br />
Recommended consumption amount for application on 1 m 2 surface is 1.0 m 2 . The said value<br />
may vary, depending on the surface and ambient conditions.<br />
PACKAGING<br />
(Panel Dimensions: 50 cm x100 cm)<br />
Number of Panels per 1 Package<br />
Mantotherm EPS 2 cm 25<br />
Mantotherm EPS 3 cm 16<br />
Mantotherm EPS 4 cm 12<br />
Mantotherm EPS 5 cm 10<br />
Mantotherm EPS 6 cm 8<br />
Mantotherm EPS 7 cm 7<br />
Mantotherm EPS 8 cm 6<br />
Mantotherm EPS 10 cm 5<br />
STORAGE CONDITIONS<br />
The product should be stored within non-tampered original packaging in dry (maximum relative<br />
humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment.<br />
It should not be exposed to direct sunlight.<br />
The product should be stored in a cool and well – ventilated environment away from such<br />
flammables as solvents, thinners.<br />
SAFETY PRECAUTIONS<br />
Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application.