Views
4 months ago

construction chemicals

Mantotherm EPS Thermal

Mantotherm EPS Thermal Insulation Panel Expanded Polystyrene Panel With High Pressure Resistance PRODUCT DESCRIPTION Expanded polystyrene panel with high pressure resistance, used for the thermal insulation of walls, columns and girders. AREAS OF USE Mantotherm EPS Thermal Insulation Panel is used as heat insulation material for the walls, terraces, floors and basements of buildings. PRODUCT ADVANTAGES • Highly resistant to pressure. • Preserves the buildings from the outer atmospheric impacts, prevents corrosion and elongates the service life of buildings. • Capable of successfully bearing the short- and long-term mechanical charges, which may occur in a building under normal conditions. • Resistant to impacts. • Has an infinite economic life. The insulating nature of the product does not change in time. • Poses low thermal conductivity. • Does not lose its thickness and endures through the time. • Very lightweight, easy to carry. • Easy to application. • Environmentally friendly. PERFORMANCE Length tolerance ± 2 mm Width tolerance ± 2 mm TS EN 822 Thickness tolerance ± 1 mm TS EN 823 Deviation from squareness ± 2 mm/m TS EN 824 Planarity tolerance ± 5 mm TS EN 825 Visual density 16 kg/m 3 TS EN 1602 Dimensional stability ± % 0.2 TS EN 1603 Compression strength in 10 % deformation 70 kPa TS EN 826 λ (Thermal Conductivity Coefficient) 0.038 W/mK TS EN 12667 Bending strength 115 kPa TS EN 12089 Long term water absorption by partial immersion ≤ 0.5 kg/m 2 TS EN 12087 Long term water absorption by total immersion ≤ % 3 TS EN 12087 Tensile strength perpendicular to surface > 100 kPa TS EN 1607 Fire class E TS EN 13501-1 The foregoing values represent the results of the laboratory tests. The values provided as per the table may vary depending on the surface and ambient conditions. REFERENCE STANDARDS Certifications/Standards TS EN 13163 TS EN 13499 ETAG 004 QUALITY CERTIFICATES TSE CE Conformant to ETAG 004. APPLICATION PROCEDURE Application Surfaces Indoors Walls; - Finishing coat applied surfaces Outdoors Walls; - Roughcast applied surfaces Surface Preparation • The application surface should be dry, clean, sound and dust-free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface. • The old plaster coat, blistering and cracks on the facades should be scraped, be repaired with MegaTamir İ or MegaTamir K, whereby a sound surface should be obtained. • In the case of bevels in excess of 2 cm on the surface; they should be repaired with MegaTamir İ or MegaTamir K before insulation application. • The surface to be insulated should not be moist, and the flooring trowel coating and internal and external wall plasters should have dried. • There should not be any moisture in progress upward on the surface, the waterproofing should be completed as necessary and should have risen 30 cm above the ground soil. • The insulation application should be initiated minimum 4 weeks after the application of roughcast. • The rain gutters, cabling elements and the like on the façade should be placed over the system and be deployed in some 6 to 7 cm distance to the system. Application Methods • Mantotherm EPS Thermal Insulation Panel, the reserve side of should have been applied Mantotherm Adhesive Mortar, should be firmly placed on the sub-basement profile. • In order for Mantotherm EPS Thermal Insulation Panel to thoroughly contact the wall 145 and to ensure the smoothness of the surface, the panel should be slipped slightly and adhered to the wall, be gauged and linaged. • Mantotherm EPS Thermal Insulation Panel should be furnished in tusk tenon fashion. The tusk tenon should be continued also in the corner joint spots of the building. • Any unintentional gaps between any two Mantotherm EPS Thermal Insulation Panel should strictly be filled with pieces to be cut from the same material. Due care must be taken to ensure that the adhesive does not overflow at the edges, where panels join, any overflowing adhesive should be cleaned and the panel edges should be ensured to be clean. • The corners of the such gaps on the surface as window gaps and door gaps should be aligned with the panel joints, the Thermal Insulation Panels should be placed as a whole on the corners, screw threads should be cut and be sized for the gaps. Hence will be eliminated the risk of cracks on the corners. • Mechanical fixation on the surface of the Thermal Insulation Panels in addition to chemical adhesion is of utmost importance for long-lasting performance. Minimum 24 hours after the adhesion of the Thermal Insulation Panels, the dowelling should be performed with thermal insulation panel dowels Mantotherm Thermal Insulation Panel Dowels. Appropriate and suitable dowels should be selected with due consideration of the insulating material employed and the surface characteristics. Application Recommendations • The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing. • Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions. • The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance. • The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours. • Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595) Surface and Ambient Temperature The surface and ambient temperature should be between +5°C and +30°C whilst at application. APPLICATION INSTRUCTIONS Application Equipment • Steel notched trowel (for EPS adhered by dredging) • Steel trowel Equipment Cleaning The equipment used should be cleaned with water following the application before the mortar dries. TECHNICAL PROPERTIES Chemical Structure: Expanded polystyrene panel Color: White CONSUMPTION Recommended consumption amount for application on 1 m 2 surface is 1.0 m 2 . The said value may vary, depending on the surface and ambient conditions. PACKAGING (Panel Dimensions: 50 cm x100 cm) Number of Panels per 1 Package Mantotherm EPS 2 cm 25 Mantotherm EPS 3 cm 16 Mantotherm EPS 4 cm 12 Mantotherm EPS 5 cm 10 Mantotherm EPS 6 cm 8 Mantotherm EPS 7 cm 7 Mantotherm EPS 8 cm 6 Mantotherm EPS 10 cm 5 STORAGE CONDITIONS The product should be stored within non-tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment. It should not be exposed to direct sunlight. The product should be stored in a cool and well – ventilated environment away from such flammables as solvents, thinners. SAFETY PRECAUTIONS Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application.

Mantotherm Platinum Thermal Insulation Panel Expanded Polystyrene Board With High Pressure Resistance PRODUCT DESCRIPTION Carbon refractory reinforced expanded polystyrene board with high pressure resistance, used for the heat insulation of walls, columns and girders. AREAS OF USE Mantotherm Platinum Thermal Insulation Panel is used as thermal insulation material for the walls, terraces, floors and basements of buildings. PRODUCT ADVANTAGES • Highly resistant to pressure. • Preserves the buildings from the outer atmospheric impacts, prevents corrosion and elongates the service life of buildings. • Capable of successfully bearing the short- and long-term mechanical charges, which may occur in a building under normal conditions. • Resistant to impacts. • Has an infinite economic life. The insulating nature of the product does not change in time. • Poses low thermal conductivity. • Does not lose its thickness and endures through the time. • Very lightweight, easy to carry. • Easy to application. • Environmentally friendly. PERFORMANCE Length tolerance ± 2 mm Width tolerance ± 2 mm TS EN 822 Thickness tolerance ± 1 mm TS EN 823 Deviation from squareness ± 2 mm/m TS EN 824 Planarity tolerance ± 5 mm TS EN 825 Visual density 16 kg/m 3 TS EN 1602 Dimensional stability ± % 0.2 TS EN 1603 Compression strength in 10 % deformation 70 kPa TS EN 826 λ (Thermal Conductivity Coefficient) 0.032 W/mK TS EN 12667 Bending strength 115 kPa TS EN 12089 Long term water absorption by partial immersion ≤ 0.5 kg/m 2 TS EN 12087 Long term water absorption by total immersion ≤ % 3 TS EN 12087 Tensile strength perpendicular to surface > 100 kPa TS EN 1607 Fire class E TS EN 13501-1 The foregoing values represent the results of the laboratory tests.The values provided as per the table may vary depending on the surface and ambient conditions. REFERENCE STANDARDS Certifications/Standards TS EN 13163 TS EN 13499 ETAG 004 QUALITY CERTIFICATES TSE CE ETA APPLICATION PROCEDURE Application Surfaces Outdoors Walls; - Roughcast applied surfaces Indoors Walls; - Finishing coat applied surfaces Surface Preparation • The application surface should be dry, clean, sound and dust-free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface. • The old plaster coat, blistering and cracks on the facades should be scraped, be repaired with MegaTamir İ or MegaTamir K, whereby a sound surface should be obtained. • In the case of bevels in excess of 2 cm on the surface; they should be repaired with MegaTamir İ or MegaTamir K before insulation application. • The surface to be insulated should not be moist, and the flooring trowel coating and internal and external wall plasters should have dried. • There should not be any moisture in progress upward on the surface, the waterproofing should be completed as necessary and should have risen 30 cm above the ground soil. • The insulation application should be initiated minimum 4 weeks after the application of roughcast. • The rain gutters, cabling elements and the like on the façade should be placed over the system and be deployed in some 6 to 7 cm distance to the system. • Mantotherm Platinum Thermal Insulation Panel should be furnished in tusk tenon fashion. The tusk tenon should be continued also in the corner joint spots of the building. • Any unintentional gaps between any two Mantotherm Platinum Thermal Insulation Panel should strictly be filled with pieces to be cut from the same material. Due care must be taken to ensure that the adhesive does not overflow at the edges, where boards join, any overflowing adhesive should be cleaned and the board edges should be ensured to be clean. • The corners of the such gaps on the surface as window gaps and door gaps should be aligned with the board joints, the thermal insulating boards should be placed as a whole on the corners, screw threads should be cut and be sized for the gaps. Hence will be eliminated the risk of cracks on the corners. • Mechanical fixation on the surface of the thermal insulating boards in addition to chemical adhesion is of utmost importance for long-lasting performance. Minimum 24 hours after the adhesion of the thermal insulating boards, the dowelling should be performed with Mantotherm Thermal Insulation Panel Dowels. Appropriate and suitable dowels should be selected with due consideration of the insulating material employed and the surface characteristics. Application Recommendations • The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing. • Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions. • The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance. • The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours. • Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595) Surface and Ambient Temperature The surface and ambient temperature should be between +5°C and +30°C whilst at application. APPLICATION INSTRUCTIONS Application Equipment - Steel notched trowel (for Platin adhered by dredging) - Steel trowel Equipment Cleaning The equipment used should be cleaned with water following the application before the mortar dries. TECHNICAL PROPERTIES Chemical Structure: Expanded polystyrene board Color: Gray CONSUMPTION Recommended consumption amount for application on 1 m 2 surface is 1.0 m 2 . The said value may vary, depending on the surface and ambient conditions. PACKAGING (Panel Dimensions: 50 cm x100 cm) Number of Panels per 1 Package Mantotherm Platinum 2 cm 25 Mantotherm Platinum 3 cm 16 Mantotherm Platinum 4 cm 12 Mantotherm Platinum 5 cm 10 Mantotherm Platinum 6 cm 8 Mantotherm Platinum 7 cm 7 Mantotherm Platinum 8 cm 6 Mantotherm Platinum 10 cm 5 STORAGE CONDITIONS The product should be stored within non-tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment. It should not be exposed to direct sunlight. The product should be stored in a cool and well – ventilated environment away from such flammables as solvents, thinners. SAFETY PRECAUTIONS Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application. Application Methods • Mantotherm Platinum Thermal Insulation Panel, the reserve side of should have been applied Mantotherm Adhesive Mortar, should be firmly placed on the sub-basement profile. • In order for Mantotherm Platinum Thermal Insulation Panel to thoroughly contact the wall and to ensure the smoothness of the surface, the board should be slipped slightly and adhered to the wall, be gauged and linaged. 146

maxicoll 2013 catalog
Nanotechnology and Construction
Mapelastic
Module 4 - Construction of a gravity fed system
Mapecem Premix Mapecem Premix - Northland Construction Supplies
Case Study - Triton Chemicals
TILING TECHNOLOGIES - Bostik
Construction Chemicals Market
PIPELINE REHABILITATION – PROTEGOL ... - TIB Chemicals AG
Flooring Systems Brochure Download (938Kb) - Triton Chemicals
Applying An External Chemical Stimulus
TEX•COTE® XL-70® BRIDGE•COTE® Brochure - Textured ...
Chemical Anchor Technical Handbook
Nanotechnology and Construction
Pure Color HP Pure Color HP - Invicon Chemical Solutions Gmbh
i n n o v a t i v e • C o a t i n g s
Disaster Resistant Construction Practices - Shelter Centre
Tygris aerosols - Chello Chemicals
Mapecem Premix Mapecem Premix - Northland Construction Supplies
Case Study - Triton Chemicals
Pervious Concrete - Euclid Chemical Co
Case Study - Triton Chemicals
Vandex Protects Drinking Water
23. masses, paints, chemicals, papers
Mapelastic Smart Mapelastic Smart - Specialtyproducts.net
En Büyük Seramik Fuarı Cersaie'de - Seramik Federasyonu
Goldsmiths Phase 2 - Triton Chemicals
Choose The Right Cement Brochure - Lafarge in South Africa
Castle Cement - MGS
Holds Art Exhibit - National Ready Mixed Concrete Association