Views
8 months ago

construction chemicals

Megaİzo CT2/CT3 - CT3

Megaİzo CT2/CT3 - CT3 Plus Fiberglass Reinforced, APP (Atactic Polypropylene) Modified Waterproofing Membrane With Plastometric Bitumen PRODUCT DESCRIPTION Waterproofing membrane with plastomeric bitumen, have physical resistance with fiberglass, and both sides of which are coated with polyethylene film. AREAS OF USE Suitable for use in balconies, terraces, flat and inclined roofs, window boxes, water canals, artificial ponds and swimming pools. PRODUCT ADVANTAGES • Crease during the application, and pose a smooth appearance. • Megaİzo CT2 / CT3 is ideal for use in hot, temperate and moderate climate zones; Megaİzo CT3 Plus is ideal for use in hot and cold (continental) climate zones. • Megaİzo CT2 / CT3 easily applicable under high temperature conditions. • Fit for application to any surface. • Easily applied to such surfaces as chimney flashings and parapets. • Ensure waterproofing throughout the life cycle of the building. • Prior to the application, the consumption amount can be clearly and precisely determined. • Pose high level of resistance to ground waters, which contain hazardous chemicals such as sulfate. • Free from any hazardous materials. The products do not pose any threats to human health and the environment. • Elastic. PERFORMANCE PROPERTIES APPLICABLE STANDARD UNIT Megaİzo CT2 / CT3 Megaİzo CT3 Plus Top surface coating - - Polyethylene film Polyethylene film Bottom surface coating - - Polyethylene film Polyethylene film Reinforcement - - Fiberglass Fiberglass Temperature resistance TS EN 1110 °C 110 120 Tensile strength TS EN 12311 - (length/ width) 1 N/5 cm 300/200 400/300 Elongation at break TS EN 12311 - (length/ width) 1 % 2/2 2/2 Cold bending TS EN 1109 °C - 5 (minimum) - 10 (minimum) The foregoing values represent the results of the laboratory tests.The values provided as per the table may vary depending on the surface and ambient conditions. REFERENCE STANDARDS Certifications/Standards TS 11758 - 1 Ministry of Public Works and Settlement Item No. Ministry of Public Works and Settlement Item No.: 04.626/5A - 5 B (Megaİzo CT2 / CT3) 04.626/1 B (Megaİzo CT3 Plus) QUALITY CERTIFICATES TSE (Megaİzo CT2 / CT3) Conformant to TS 11758 - 1. (Megaİzo CT3 Plus) CE APPLICATION PROCEDURE Surface Preparation • The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface. • The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 24 hours in advance. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred. • The molding oil residues on the concrete surface, if any, should be cleaned with high pressure water. The surface should, upon drying, be prepared for application with MegaFilm İzo. Application Methods • Edge and corner joints should be beveled with MegaTamir İ and MegaTamir K repair mortars in order for the maintenance of waterproofing. • The bottom surface of the cover should be molten with blowpipe flame, and should be adhered to make sure that the margin parts at joints overlap. • Margin parts should be allowed at the joint points by 10 cm on the width and by 15 cm on the length. • The membrane tiers should be formed perpendicularly in the same direction as the slope at all layers, and tusk tenon should be applied between any two tiers to ensure that the joint points do not overlap to the furthest extent possible. Application Recommendations • Due care must be taken to make sure that the membrane selected is suitable for the prevailing climate conditions and the physical characteristics of the building. • Due care must be taken to make sure that all parts are adhered upon the completion of the application. • In cold weather conditions, the membrane should be kept in a warm environment prior to the application, and applied at such temperatures higher than +5°C. • The insulation should be sandwiched between steel flanges at crossing spots, where the insulation is likely to be punctured. • Due care must be taken to ensure that the insulation material is not damaged by mechanical impacts in the cases of coating over the insulation. • The application surface should never be left uncovered. • The product should not be applied on unsound surfaces. The soundness and the load-bearing capacity of old surfaces should be checked prior to adhesion. • The surface should be preserved from air currents and water contact during and after the application. • The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing. • Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions. • The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance. • The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours. • Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595) APPLICATION INSTRUCTIONS Application Equipment Blowpiper Trowel TECHNICAL PROPERTIES Chemical Structure: Fiberglass reinforced, APP (atactic polypropylene) modified waterproofing membrane with plastomeric bitumen Thickness: 2 mm, 3 mm Roll Weight: 35 kg Roll Dimensions (Width/Length): 15 m 2 (2 mm), 10 m 2 (3 mm) CONSUMPTION The recommended consumption amount varies, depending on the size of the application surface. PACKAGING Megaİzo CT2 is delivered in the form 1 meter wide and 15 meters long at total of 30 rolls on 100x120 cm sizes palette. Megaİzo CT3, Megaİzo CT3 Plus are delivered in the form 1 meter wide and 10 meters long at total of 30 rolls on 100x120 cm sizes palette. STORAGE CONDITIONS The product should be stored within non-tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment in the form of rolls, stowed upright. It should not be exposed to direct sunlight. The product should be protected from UV lights and sudden changes in temperature. The product should not be stored in overlapping rolls. SAFETY PRECAUTIONS Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application. 73

Megaİzo PK3/PK4 - PK3/PK4 Plus - PK3/PK4 Super Plus APP (Atactic Polypropylene) Modified, Plastomeric Bitumen, With Polyester Seal Carrier; (Megaİzo PK3/PK4, Megaİzo PK3/PK4 Plus) and SBS (Styrene-Butadiene-Styrene) Modified, Elastomeric Bitumen (Megaİzo PK3/PK4 Super Plus) Water Insulation Membrane PRODUCT DESCRIPTION Plastomeric/elastomeric bitumen water insulation membrane, coated with polyethylene film at both sides, the physical resistance of which has been increased by polyester seal. AREAS OF USE Suitable for use in foundations, bridges, viaducts, large size structures of art, tunnels, artificial ponds, water canals, waste storage areas, treatment plants and swimming pools. PRODUCT ADVANTAGES • Highly resistant to ruptures and tears. • Resistant to adverse impacts, which may arise in the soil. • Highly resistant to heavy building loads. • Megaİzo PK3 / PK4 is ideal for use in hot, temperate and moderate climate zones; Megaİzo PK3 / PK4 Plus is ideal for use in hot and cold (continental) climate zones; Megaİzo PK3 / PK4 Super Plus is ideal for use in cold climate zone • Megaİzo PK3 / PK4 is easily applicable under high temperature conditions; Megaİzo PK3 / PK4 Super Plus is easily applicable under low temperature conditions • Easily applied to such surfaces as chimney flashings and parapets. • Ensure waterproofing throughout the life cycle of the building. • Prior to the application, the consumption amount can be clearly and precisely determined. • Pose high level of resistance to ground waters, which contain hazardous chemicals such as sulfate. • Free from any hazardous materials. The products do not pose any threats to human health and the environment. • Elastic. PERFORMANCE PROPERTIES APPLICABLE STANDARD The foregoing values represent the results of the laboratory tests. The values provided as per the table may vary depending on the surface and ambient conditions. REFERENCE STANDARDS Certifications/Standards TS 11758 - 1 UNIT Ministry of Public Works and Settlement Item No. Ministry of Public Works and Settlement Item No: 04.626/6A - 6F (Megaİzo PK3 / PK4) 04.626/2A - 2G (Megaİzo PK3 / PK4 Plus) 04.626/4A - 4G (Megaİzo PK3 / PK4 Super Plus) Megaİzo PK3 / PK4 QUALITY CERTIFICATES TSE (Megaİzo PK3 / PK4, Megaİzo PK3 / PK4 Plus) Conformant to TS 11758 - 1. (Megaİzo PK3 / PK4 Super Plus) CE Megaİzo PK3 / PK4 Plus Polyethylene film Polyethylene film Megaİzo PK3 / PK4 Super Plus Polyethylene film Polyethylene film Top surface coating - - Polyethylene film Bottom surface Polyethylene - - coating film Reinforcement - - Polyester Polyester Polyester Temperature resistance TS EN 1110 °C 110 120 110 Tensile strength (length/ width) TS EN 12311 - 1 N/5 cm 600/400 800/600 800/600 Elongation at break (length/ width) TS EN 12311 - 1 % 30/30 35/35 35/35 Cold bending TS EN 1109 °C - 5 (minimum) - 10 (minimum) - 20 (minimum) APPLICATION PROCEDURE Surface Preparation • The application surface should be dry, clean, sound and dust free, and should have been cleansed of oil, dirt or any materials that may prevent adhesion, and any such materials as mortar and cement residues should be scraped from the application surface. • The surface defects, which are deeper than 1 cm, should be repaired with MegaTamir İ or MegaTamir K 24 hours in advance. In the cases, where structural repair mortar should be used; MegaTamir İ Yapısal or MegaTamir K Yapısal should be preferred. • The molding oil residues on the concrete surface, if any, should be cleaned with high pressure water. The surface should, upon drying, be prepared for application with MegaFilm İzo. Application Methods • Edge and corner joints should be beveled with MegaTamir İ and MegaTamir K repair mortars in order for the maintenance of waterproofing. • The bottom surface of the cover should be molten with blowpipe flame, and should be adhered to make sure that the margin parts at joints overlap. • Margin parts should be allowed at the joint points by 10 cm on the width and by 15 cm on the length. • The membrane tiers should be formed perpendicularly in the same direction as the slope at all layers, and tusk tenon should be applied between any two tiers to ensure that the joint points do not overlap to the furthest extent possible. Application Recommendations • Due care must be taken to make sure that the membrane selected is suitable for the prevailing climate conditions and the physical characteristics of the building. • Due care must be taken to make sure that all parts are adhered upon the completion of the application. • In cold weather conditions, the membrane should be kept in a warm environment prior to the application, and applied at such temperatures higher than +5°C. • The products should be applied in single coat or double coats for foundation waterproofing applications, depending on the ground water content of the soil, the prevailing geographical conditions of the region and the ground structure. • In the case of basement tanking application against pressure water, the products are, generally, recommended to be applied in double coats. • For roof insulation applications, if the slope is more than 5%, then one-coat of Megaİzo PK4, Megaİzo PK4 Plus or Megaİzo PK4 Super Plus could be applied according to the climate conditions and physical properties of the structures. • The insulation should be sandwiched between steel flanges at crossing spots, where the insulation is likely to be punctured. • Due care must be taken to ensure that the insulation material is not damaged by mechanical impacts in the cases of coating over the insulation. • The application surfaces should, with due consideration of the related details, be covered and protected with thermal insulation panels, drainage panels, geo-textile seal etc., and the application surface should never be left uncovered. • The product should not be applied on unsound surfaces. The soundness and the load-bearing capacity of old surfaces should be checked prior to adhesion. • The surface should be preserved from air currents and water contact during and after the application. • The product should not be applied to such surfaces, which are exposed to risk of freezing within the next 24 hours, which are frozen or the frost of which is thawing. • Due care should be given to prevent the exposure of the material to direct sunlight in hot weather conditions. • The product should not be applied on extremely windy weather conditions or on hot surfaces, which are exposed to direct sunlight; and in the cases, where application is imperative under such conditions, the environment and the surface should be prepared for application in advance. • The product should not be applied in rainy weather conditions, and the application surface should be preserved from rain for a period of 24 hours. • Refer to our technical support hotline for recommendation on different surface applications. (PHONE: 444 4 595) APPLICATION INSTRUCTIONS Application Equipment Blowpiper Trowel TECHNICAL PROPERTIES Chemical Structure: APP (atactic polypropylene) modified, plastomeric bitumen, with Polyester seal carrier; (Megaİzo PK3 / PK4, Megaİzo PK3 / PK4 Plus) and SBS (styrene -butadiene-styrene) modified, elastomeric bitumen (Megaİzo PK3 / PK4 Super Plus) water insulation membrane Thickness: 3 mm, 4 mm Roll Weight: 35 kg (3 mm), 45 kg (4 mm) Roll Dimensions (Width/Length): 10 m 2 CONSUMPTION The recommended consumption amount varies, depending on the size of the application surface. PACKAGING Megaİzo PK3, Megaİzo PK3 Plus, Megaİzo PK3 Super Plus are delivered in the form 1 meter wide and 10 meters long at total of 30 rolls on 100x120 cm sizes palette. Megaİzo PK4, Megaİzo PK4 Plus, Megaİzo PK4 Super Plus are delivered in the form 1 meter wide and 10 meters long at total of 20 rolls on 100x120 cm sizes palette. STORAGE CONDITIONS The product should be stored within non-tampered original packaging in dry (maximum relative humidity 60 %) and cool (ambient temperature between +5°C and +25°C) environment in the form of rolls, stowed upright. It should not be exposed to direct sunlight. The product should be protected from UV lights and sudden changes in temperature. The product should not be stored in overlapping position. SAFETY PRECAUTIONS Please refer to the Safety Data Sheet (SDS) as appropriate for easy and safe application. 74

Paver Reneu Bro 8.5x11 - Vexcon Chemicals
Planicrete AC Planicrete AC - Northland Construction Supplies
Chemicals For Sustainable Construction - Roof & Facade
BASF CC Brochure - BASF Construction Chemicals Pacific
Durable Connections - BASF Construction Chemicals Pacific
Construction Chemicals Market Revenue and Value Chain 2014-2020
Download water pollution from construction leaflet - States of Jersey
Flooring Systems Brochure Download (938Kb) - Triton Chemicals
India Construction Chemicals Market
Superior Products Coating Products Line Brochure
Planicrete AC Planicrete AC - Northland Construction Supplies
Nanotechnology and Construction
Ground Gas Barriers Brochure Download - Triton Chemicals
Basic Construction Materials - Icee.usm.edu
Modern Methods of Construction - Masonryfirst.com
Sustainable Construction Materials and ... - UW-Milwaukee
Pure Color HP Pure Color HP - Invicon Chemical Solutions Gmbh
Module 4 - Construction of a gravity fed system