SINEAX A 210 / A 220 Multifunctional Power Monitor Display levels: e.g. 4-wire unbalanced load 1 2 3 4 5 U1 U2 U3 I1 I2 I3 P1 P2 P3 Q1 Q2 Q3 S1 S2 S3 P a b c d e f U1 max. U2 max U3 max I1 max. I2 max I3 max U1 min. U2 min. U3 min. I1 avg I2 avg I3 avg U12 U23 U31 P1 max P2 max. P P max. P3 max Q1 max. Q2 max. Q Q max. Q3 max S1 max. S2 max S S max. S3 max. U12 max. U23 max. U31 max. U12 min. U23 min. U31 min. I1 avgmax. I2 avgmax. IN IN max. I3 avgmax. 6 PF1 PF2 PF3 PF PF minind PF mincap 7 F 8 EPinc HT 1 EP inc LT 2 EP out HT 1 EP out LT 2 9 EQ ind HT 1 EQ ind LT 2 EQ cap HT 1 EQ cap LT 2 10 P Q PF P S F 11 Pint0 Pint1 Pint2 Pint3 Pint4 12 Qint0 Qint1 Qint2 Qint3 Qint4 13 Sint0 Sint1 Sint2 Sint3 Sint4 1 HT = High tariff 2 LT = Low tariff Safety Protection class: Measuring category: Pollution degree: 2 Measurement voltage: 300 V Test voltage: II (voltage inputs with protection impedances) III Between current inputs, power supply, digital outputs, terminals of the plugged-in module: 3700 V / 50 Hz / 1 min. On voltage inputs: 4.25 kV 1.2/50 μs Module connections: The pin rail at the back is connected to the voltage inputs via a protec-tion impedance. Only the permitted modules can be plugged-in! Enclosure protection: Front IP 66, terminals IP 20 Accuracy data Reference conditions acc. to IEC 688 resp. EN 60 688 Sine 50 - 60 Hz, 15 - 30°C, application group II Measurement accuracy (related to nominal value) Current, voltage ± 0.5% Power ± 1.0% Power factor ± 1.0% Energy ± 1.0% Frequency ± 0.02 Hz (abs.) Mechanic Dimensions A 210: 96 x 96 x 46 mm; Panel cutout 92 +0.8 x 92 +0.8 mm A 220: 144 x 144 x 46 mm; Panel cutout 138 +1 x 138 +1 mm Terminals: Inputs Screw terminals Wire gauge single wire: 0.5 - 2.5 mm 2 Wire gauge fi ne wire: 0.5 - 1.5 mm 2 Power supply, outputs Clamps Wire gauge single and fi ne wire: 0.5 - 1.5 mm 2 Housing material: Weight: Mounting: Environmental conditions Operating temperature: – 10 to + 55 °C Storage temperature: – 25 to + 70 °C Humidity relative: ≤ 75% Altitude: 2000 m max. Indoor use statement ABS flammability class V-0 acc. to UL 94, self-extinguishing, nondripping, free of halogen 250 g at A 210 resp. 300 g at A 220 For control panel mounting Inputs, outputs and power supply are electrically isolated. The current inputs are electrically isolated from each other. 6 Data Sheet A 210/A 220 Le – 03.13 Camille Bauer

SINEAX A 210 / A 220 Multifunctional Power Monitor Electrical connections System / application Terminals 2 5 8 1 3 7 9 2 5 8 1 3 7 9 Measuring input, acc. to measuring mode I1 U1 I2 U2 I3 U3 N 3-wire 3 phase asymmetric load L1 L2 L3 2 5 8 1 3 7 9 L1 L2 L3 k l K L k l 2 5 8 1 3 7 9 K L u u u 1 2 3 4 5 6 7 I1 U1 I1 I2 U2 I2 I3 UL: 3~300V 5A 50/60Hz CAT III IEC: 3~500/290V 5A 50/60Hz CAT III SINEAX A210 Mat: 149783/1234567/001 210-121200 Man: 10/02 NLBxxxx SO 1 2 LOCK 22 21 20 8 U3 9 I3 11 N Camille Bauer AG Switzerland 100-230V AC 85-125V DC 50-400Hz 3VA 14 15 u U L1 L2 L3 v V 2 u U v V k l K L k l 11 1 3 K L L1 L2 L3 x X U x X U x X U 2 11 1 3 k l K L k l K L k l System / application Single-phase AC system 1 2 + Pulse / Limit value outputs Connecting modes L1 N Jumper 2 11 1 3 2 11 1 3 Power supply Terminals L1 N 2 11 1 3 K k l L 4-wire 3 phase symmetric load I: L1 L1 L2 L3 N L1 L2 L3 N u U 2 11 1 3 v V K k l L L1 L2 L3 Connect the voltage according to the following table for current measurement in L2 or L3: Current transf. Terminals 2 11 L2 1 3 L2 N L3 1 3 L3 N N K L u v 2 5 8 11 1 3 4 6 7 9 L1 N U 2 5 8 1 3 V K k l L 2 5 8 1 3 L1 L2 L3 N 3-wire, 3-phase symmetric load I: L1 L1 L2 L3 u U L1 L2 L3 2 5 8 1 3 v V u U v V K k l L L1 L2 L3 K k l L 4-wire 3 phase asymmetric load L1 L2 L3 N 2 5 8 11 1 3 4 6 7 9 u x u x u x K k 2 5 8 11 1 3 4 6 7 9 l L K k l L K k l L Connect the voltage according to the following table for current measurement in L2 or L3: L1 L2 L3 N X U X U X U K k l L K k l L K k l L Current Terminals 2 5 8 transf. L2 1 3 L2 L3 L1 L3 1 3 L3 L1 L2 3 single-pole insulated voltage transformers in high-voltage system Camille Bauer Data Sheet A 210/A 220 Le – 03.13 7

SMS Matters?
MAGNUM SM
AZOutage_Report_01MAY12-sm
Empoweringuniversities sm
SCA_Issue1_Spr2014_Web SM
SM-2M
SMS Corporativo
Cover SMS New-1.cdr - SMS Lucknow
SMS - The Matrix - April 2014
SM-PDX1A-NATIONALADVOCATE-ISSUE2
TME-NovDec2016-Online-SM
SM Platform Differentiators