Views
1 month ago

O & M Manual

To shut Down the Boiler

To shut Down the Boiler 1. For short periods Set the external controls to OFF. Wait 4 minutes and then isolate the mains supply to the boiler. 2. For longer periods Set the external controls to OFF. Switch the electricity supply to OFF. For longer periods the entire system should be drained, including the domestic hot water supply. To Relight the Boiler Refill the system if it has been drained, taking care to ensure no air is in the boiler or system. Repeat the procedure detailed in ‘To light the boiler’. Frost Protection The Keston Heat boiler has built into its control system the facility to protect the boiler only against freezing. Note. This may not protect remote parts of the system, in which case a separate frost thermostat should be fitted. Boiler Overheat Thermostat Boiler overheating is detected by electrical sensors connected to the boiler control module. If the boiler overheats it will shut down and the display will show Overheat Lockout. Press the reset button and the boiler will relight. If the fault recurs turn off the boiler and consult a Gas Safe Registered Engineer or in IE a competent person. Condensate Drain This appliance is fitted with a siphonic condensate trap system that reduces the risk of the appliance condensate from freezing. However should the condensate pipe to this appliance freeze, please follow these instructions: 2. Apply a hot water bottle, microwaveable heat pack or a warm damp cloth to the frozen blockage area. Several applications may have to be made before it fully defrosts. Warm water can also be poured onto the pipe from a watering can or similar. DO NOT use boiling water. 3. Caution when using warm water as this may freeze and cause other localised hazards. 4. Once the blockage is removed and the condensate can flow freely, reset the appliance. (Refer to “To Light the boiler”) 5. If the appliance fails to ignite, call your Gas Safe Registered engineer. Preventative solutions During cold weather, set the boiler stat to maximum, (Must return to original setting once cold spell is over) Place the heating on continuous and turn the room stat down to 15ºC overnight or when unoccupied. (Return to normal after cold spell). Escape of Gas Should a gas leak or fault be suspected contact your local gas supplier without delay. Do NOT search for gas leaks with a naked flame. Cleaning For normal cleaning simply dust with a dry cloth. To remove stubborn marks and stains use a damp cloth and mild detergent. DO NOT use abrasive cleaning materials. a. If you do not feel competent to carry out the defrosting instructions below please call your local Gas Safe Registered installer for assistance. b. If you do feel competent to carry out the following instructions please do so with care when handling hot utensils. Do not attempt to thaw pipework above ground level. If this appliance develops a blockage in its condensate pipe, its condensate will build up to a point where it will make a gurgling noise prior to locking out displaying “Ignition Lockout” on the display. If the appliance is reset it will make a gurgling noise prior to it locking out displaying “Ignition Lockout” on the display. To unblock a frozen condensate pipe; 1. Follow the routing of the plastic pipe from its exit point on the appliance, through its route to its termination point. Locate the frozen blockage. It is likely that the pipe is frozen at the most exposed point external to the building or where there is some obstruction to flow. This could be at the open end of the pipe, at a bend or elbow, or where there is a dip in the pipe in which condensate can collect. The location of the blockage should be identified as closely as possible before taking further action. Keston Heat - User’s 5

6 Keston Heat - User’s

  • Page 1 and 2:

    Health & Safety File including Oper

  • Page 3 and 4:

    Health & Safety File Introduction T

  • Page 5 and 6:

    Health & Safety File Health and Saf

  • Page 7 and 8:

    Health & Safety File Description of

  • Page 9 and 10:

    Health & Safety File Material Suppl

  • Page 11 and 12:

    Quote 1055856 Customer name: Graham

  • Page 13 and 14:

    Quote 1056741 Customer name: Graham

  • Page 15 and 16:

    Health & Safety File Drawings and S

  • Page 17 and 18:

    Ivy Cottage Bathrooms Fixtures and

  • Page 19 and 20:

    Ivy Cottage Bathrooms Fixtures and

  • Page 21 and 22:

    Ivy Cottage Bathrooms Fixtures and

  • Page 23 and 24:

    Ivy Cottage Bathrooms Fixtures and

  • Page 25 and 26:

    Ivy Cottage Bathrooms Fixtures and

  • Page 27 and 28:

    Ivy Cottage Paints and Wall Paper S

  • Page 29 and 30:

    Ivy Cottage Paints and Wall Paper S

  • Page 31 and 32:

    Ivy Cottage Paints and Wall Paper S

  • Page 33:

    Health & Safety File Certification

  • Page 44 and 45:

    Riverside Environmental Services Lt

  • Page 46 and 47:

    Job No: J112167 Section 1: Executiv

  • Page 48 and 49:

    Job No: J112167 Locations containin

  • Page 50 and 51:

    Job No: J112167 Section 2: Contact

  • Page 52 and 53:

    Job No: J112167 3.1.1 Description,

  • Page 54 and 55:

    Job No: J112167 G.02 Store Cupboard

  • Page 56 and 57:

    Job No: J112167 1.07 Shower Room Iv

  • Page 59:

    Job No: J112167 Sample number Locat

  • Page 62 and 63:

    Job No: J112167 Sample N o Location

  • Page 64 and 65:

    Job No: J112167 Sample N o VC CE001

  • Page 66 and 67:

    Job No: J112167 Section 7: Appendic

  • Page 68 and 69:

    Job No: J112167 IV - Certificates o

  • Page 70:

    Job No: J112167 V - Site Drawings P

  • Page 78 and 79:

    Job No: J112167 VII - Glossary of T

  • Page 80 and 81:

    Health & Safety File Operation, Car

  • Page 90 and 91: Health & Safety File QBS Electrical
  • Page 92 and 93: CONTENTS INTRODUCTION 1 HEALTH & SA
  • Page 94 and 95: ELEC O&M Ivy Cottage SECTION 2 HEAT
  • Page 96 and 97: ELEC O&M Ivy Cottage Accidents Invo
  • Page 98 and 99: ELEC O&M MANUAL: Ivy Cottage SECTIO
  • Page 100 and 101: FAULT FINDING/PERIODIC TEST AND EME
  • Page 102 and 103: EMERGENCY LIGHTING QBS ELECTRICAL L
  • Page 104 and 105: SMALL POWER QBS ELECTRICAL LTD 168
  • Page 106 and 107: ELEC O&M MANUAL: Ivy Cottage SECTIO
  • Page 108 and 109: ELEC O&M MANUAL: Ivy Cottage SECTIO
  • Page 110: QBS ELECTRICAL LTD 168 Whitton Aven
  • Page 120: ELEC O&M MANUAL: Ivy Cottage SECTIO
  • Page 123 and 124: DATA SHEET: UCL series ISSUE: BADEC
  • Page 125 and 126: Crown Flooring Operation & Maintena
  • Page 127 and 128: 5. Cleaning and Maintenance Registe
  • Page 129 and 130: Registered in England and Wales: Co
  • Page 131 and 132: Registered in England and Wales: Co
  • Page 133 and 134: Registered in England and Wales: Co
  • Page 136 and 137: Heat 45 & 55 User Instructions FAN
  • Page 138 and 139: 1 BOILER CONTROLS / DISPLAY 1st STA
  • Page 142 and 143: Keston Heat - User’s 7
  • Page 144 and 145: Health & Safety File Cambridge Stov
  • Page 146 and 147: CONTENTS INDEX: WARRANTY………
  • Page 148 and 149: PLEASE READ THESE INSTRUCTIONS PRIO
  • Page 150 and 151: REMOVING INTERNAL COMPONENTS All in
  • Page 152 and 153: RE-ASSEMBLING THE STOVE Front Dimen
  • Page 154 and 155: LEGAL REQUIREMENTS Hunter Stoves Gr
  • Page 156 and 157: COMMISSIONING & HANDOVER APPLIANCE
  • Page 158 and 159: B) To operate pull the air control
  • Page 160 and 161: FIREBRICKS In normal use, these can
  • Page 162 and 163: OPERATION SMOKE PROBLEMS ADVERSE WE
  • Page 164 and 165: STOVE CARE PRODUCTS All replacement
  • Page 166 and 167: BODY ASSEMBLY SPARES ASPECT COMPACT
  • Page 168 and 169: SERVICE RECORDS 1 st Service Date o
  • Page 170 and 171: For both Solid Fuel and Gas Stoves:
  • Page 172 and 173: CONTENTS INDEX: WARRANTY………
  • Page 174 and 175: PLEASE READ THESE INSTRUCTIONS PRIO
  • Page 176 and 177: REMOVING INTERNAL COMPONENTS All in
  • Page 178 and 179: RE-ASSEMBLING THE STOVE Refit all t
  • Page 180 and 181: comply with current Building Regula
  • Page 182 and 183: COMMISSIONING & HANDOVER APPLIANCE
  • Page 184 and 185: B) To operate pull the air control
  • Page 186 and 187: FIREBRICKS In normal use, these can
  • Page 188 and 189: OPERATION SMOKE PROBLEMS ADVERSE WE
  • Page 190 and 191:

    STOVE CARE PRODUCTS All replacement

  • Page 192 and 193:

    BODY ASSEMBLY SPARES ASPECT 5 SLIML

  • Page 194 and 195:

    SERVICE RECORDS 1 st Service Date o

  • Page 196:

    For both Solid Fuel and Gas Stoves:

  • Page 200 and 201:

    R and N Construction 135 Sunnymead

  • Page 202 and 203:

    7 YEAR LIFE CARBON MONOXIDE POISONO

  • Page 204 and 205:

    CONTENTS Features 4 Carbon monoxide

  • Page 206 and 207:

    CO enters the body through the lung

  • Page 208 and 209:

    WARNING: This carbon monoxide detec

  • Page 210 and 211:

    WHERE TO INSTALL YOUR DETECTOR This

  • Page 212 and 213:

    In addition to the above the follow

  • Page 214 and 215:

    To mount on a wall or ceiling: Plea

  • Page 216 and 217:

    This should be continued for the li

  • Page 218 and 219:

    test for the sounder, power pack an

  • Page 220 and 221:

    15cm (6”) Step 4 Turn the detecto

  • Page 222 and 223:

    • Within 3 minutes when exposed t

  • Page 224 and 225:

    WHAT TO DO IN THE EVENT OF AN ALARM

  • Page 226 and 227:

    The alarm will sound: • Between 6

  • Page 228 and 229:

    This warranty does not affect your

  • Page 230 and 231:

    Electrical WARNING - THIS APPLIANCE

  • Page 232 and 233:

    Energy Saving Tips The energy we us

  • Page 234 and 235:

    Technical Information SPM 150W/m²

  • Page 236 and 237:

    Do’s and Don’ts DO Carefully re

  • Page 238 and 239:

    Electrical Safety Considerations As

  • Page 240 and 241:

    Installing the Mat (Continued) Step

  • Page 242 and 243:

    Control Card Place this card in a v

  • Page 244:

    Warmup plc., United Kingdom 702 & 7

  • Page 247 and 248:

    Contents Contents Safety informatio

  • Page 249 and 250:

    Safety information Congratulations

  • Page 251 and 252:

    Safety information 4. If the supply

  • Page 253 and 254:

    Safety information This appliance s

  • Page 255 and 256:

    Safety information Do not let child

  • Page 257 and 258:

    Safety information • The liquid d

  • Page 259 and 260:

    Safety information Instructions abo

  • Page 261 and 262:

    Installation Spanner Bolt caps Hose

  • Page 263 and 264:

    Installation Installation Flooring

  • Page 265 and 266:

    Installation STEP 3 Adjust the leve

  • Page 267 and 268:

    Installation 8. Connect the other e

  • Page 269 and 270:

    Installation STEP 5 Position the dr

  • Page 271 and 272:

    Before you start Initial settings R

  • Page 273 and 274:

    Before you start STEP 6 Apply a pro

  • Page 275 and 276:

    Before you start NOTE The actual ap

  • Page 277 and 278:

    Before you start To use liquid dete

  • Page 279 and 280:

    Operations Operations Press to chan

  • Page 281 and 282:

    Operations Cycle overview Standard

  • Page 283 and 284:

    Operations Options Option Pre Wash

  • Page 285 and 286:

    Operations Settings Child Lock To p

  • Page 287 and 288:

    Maintenance Smart Check To enable t

  • Page 289 and 290:

    Maintenance Cleaning Surface of the

  • Page 291 and 292:

    Maintenance Detergent drawer A 1. W

  • Page 293 and 294:

    Troubleshooting Checkpoints If you

  • Page 295 and 296:

    Troubleshooting Troubleshooting Sto

  • Page 297 and 298:

    Troubleshooting Information codes I

  • Page 299 and 300:

    Troubleshooting Code AC6 Action Che

  • Page 301 and 302:

    Specifications Protecting the envir

  • Page 303 and 304:

    Specifications Power consumption Ty

  • Page 305 and 306:

    Specifications According to Regulat

  • Page 307 and 308:

    Specifications According to Regulat

  • Page 309 and 310:

    Specifications According to Regulat

  • Page 311 and 312:

    Memo Untitled-1 66 2017-06-26 3:17:

  • Page 313 and 314:

    QUESTIONS OR COMMENTS? COUNTRY CALL

  • Page 315 and 316:

    Contents Contents Safety informatio

  • Page 317 and 318:

    Safety information Congratulations

  • Page 319 and 320:

    Safety information 7. For use in Eu

  • Page 321 and 322:

    Safety information Safety informati

  • Page 323 and 324:

    Safety information When gas (city g

  • Page 325 and 326:

    Safety information • This may res

  • Page 327 and 328:

    Installation Accessories (supplied)

  • Page 329 and 330:

    Installation Location requirements

  • Page 331 and 332:

    Installation Drain hose (if necessa

  • Page 333 and 334:

    Installation By using the drain pip

  • Page 335 and 336:

    Installation 2. Use a thin object t

  • Page 337 and 338:

    Installation 8. Remove the 2 screws

  • Page 339 and 340:

    Installation 2. Remove 2 screws (A)

  • Page 341 and 342:

    Installation 8. Move the bottom scr

  • Page 343 and 344:

    Operations Displays all cycle infor

  • Page 345 and 346:

    Operations Cycle overview Operation

  • Page 347 and 348:

    Operations Cycle chart NOTE For bes

  • Page 349 and 350:

    Operations Rack Dry (applicable mod

  • Page 351 and 352:

    Operations Cycle guide Always follo

  • Page 353 and 354:

    Maintenance WARNING • Do not clea

  • Page 355 and 356:

    Maintenance Water tank To avoid lea

  • Page 357 and 358:

    Maintenance 4. Clean the heat excha

  • Page 359 and 360:

    Troubleshooting Symptom Lint on clo

  • Page 361 and 362:

    Appendix Iron dry or steam temperat

  • Page 363 and 364:

    Appendix DV9*M50****, DV8*M50****,

  • Page 365 and 366:

    Appendix Sheet of household tumble

  • Page 367 and 368:

    Appendix NOTE 1. Energy consumption

  • Page 369:

    QUESTIONS OR COMMENTS? COUNTRY CALL

Isolator Row O&M Manual
GRUNFOS FIRE SYSYTEMS O & M MANUALS - Xact
M & O O O
M & O O O
A FOCUS ON A m o N
SMUD O&M Experience
a f m o a f m o o
Electronic O&M Manuals Information at Your ... - NC AWWA-WEA
PR O M O T IN G
A V O F A R M
O V ^=m - Newspaper Archive
M A T I O N
M O S T Y
l ’ O l m o
w w w. e ri c s o m m e r. c o m
O wners M anual
A U T O M A T I O N - Victor Technologies
in & m o tiva te - Handwashing for Life Foodservice
Download O&M Phase Support - SeaEnergy PLC
many m riders o where - Rapid Wheelmen
– N A M O G U R U –
W E L C O M E !
W E L C O M E
R O BO TIC M A SSAGE CHAIR
M O N T H L Y
C O M P A S S - Motorwebs
Alabama Di a m o n d
m a m o n d i a l i s a t i o n