12.04.2018 Views

-TechManual_SRK05,09,12CR-S,CRR-S,CRP-S

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Item<br />

Model<br />

'15 • SRK-T-171<br />

SRK<strong>09</strong><strong>CRP</strong>-S5<br />

Indoor unit SRK<strong>09</strong><strong>CRP</strong>-S5<br />

Outdoor unit SRC<strong>09</strong><strong>CRP</strong>-S5<br />

4.3<br />

Fine snow<br />

Stucco white<br />

(8.0Y 9.3/0.1) near equivalent<br />

(4.2Y 7.5/1.1) near equivalent<br />

Liquid line : 0.46<br />

—<br />

Gas line : 0.40<br />

Necessary (Both sides), independent<br />

Max. 15<br />

Max.5 (Outdoor unit is higher)<br />

Max.5 (Outdoor unit is lower)<br />

1.5mm 2 x 3 cores (Including earth cable)<br />

Terminal block (Screw fixing type)<br />

Mounting kit<br />

The pipe length is 5m.<br />

Standards<br />

- 15 -<br />

Cooling capacity (1) W 2500<br />

Power source<br />

1 Phase, 220-240V, 50Hz<br />

Operation<br />

data<br />

Power<br />

consumption<br />

Running<br />

current<br />

Cooling kW 0.925<br />

Cooling<br />

A<br />

Inrush current 15<br />

COP Cooling 2.70<br />

Noise<br />

level<br />

Cooling<br />

Sound level dB(A) 43 51<br />

Power level dB 57 62<br />

Exterior dimensions (Height x Width x Depth) mm 262 x 615 x 210 435 x 645 (+50) x 275<br />

Exterior appearance<br />

(Munsell color)<br />

Net weight kg 6 24<br />

Refrigerant<br />

equipment<br />

Air handling<br />

equipment<br />

Compressor type & Q'ty — GKS102PAB (Rotary type) x 1<br />

Motor (Starting method) kW — PSC<br />

Refrigerant oil l 0.30 (POE [RB68A] or PVE [FVC68D])<br />

Refrigerant (4) kg R410A 0.48 ( Pre-charged up to the piping length of 5m )<br />

Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing<br />

Refrigerant control<br />

Capillary tubes<br />

Device control<br />

Microcomputer control<br />

Fan type & Q'ty Cross flow fan x 1 Propeller fan x 1<br />

Motor W 17 22<br />

Air flow Cooling m 3 /min 9 23<br />

Fresh air intake Not possible —<br />

Air filter, Quality / Quantity Polypropylene net (washable) x 1 —<br />

Shock & vibration absorber — Cushion rubber (for compressor)<br />

Operation<br />

control<br />

Safety devices<br />

Installation<br />

data<br />

Operation switch Wireless remote control —<br />

Room temperature control Microcomputer thermostat —<br />

Operation display<br />

RUN : Green, TIMER : Yellow<br />

Compressor overheat protection, Overcurrent protection,<br />

Frost protection, Serial signal error protection, Indoor Fan motor error protection,<br />

Cooling overload protection<br />

Refrigerant piping size (O.D) mm Liquid line: φ6.35 (1/4") Gas line: φ9.52 (3/8")<br />

Connecting method<br />

Flare connecting<br />

Attached length of piping<br />

Insulation for piping<br />

Refrigerant line (one way) length<br />

Vertical height difference between<br />

outdoor unit and indoor unit<br />

m<br />

m<br />

Drain hose Connectable (VP 16) —<br />

Power cable —<br />

Recommended breaker size A 10<br />

Size x Core number<br />

Connection wiring<br />

Connecting method<br />

Accessories (included)<br />

Option parts —<br />

Note (1) The data are measured at the following conditions.<br />

Operation<br />

Item<br />

Indoor air temperature<br />

Outdoor air temperature<br />

DB WB DB WB<br />

Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612<br />

(2) This air-conditioner is manufactured and tested in conformity with the ISO.<br />

(3) The operation data are applied to the 220V districts respectively.<br />

(4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.<br />

(Purging is not required even for the short piping.)<br />

If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!